ML20128N457

From kanterella
Jump to navigation Jump to search
Forwards Rev 5 to Technical Evaluation Rept for Defueling Water Cleanup Sys, Correcting & Clarifying Description of Low Level Alarm Setpoints for Fuel Transfer Canal.Sys Description Will Be Revised Accordingly
ML20128N457
Person / Time
Site: Crane Constellation icon.png
Issue date: 05/28/1985
From: Standerfer F
GENERAL PUBLIC UTILITIES CORP.
To: Snyder B
Office of Nuclear Reactor Regulation
Shared Package
ML20128N462 List:
References
0260A, 260A, 4410-85-L-0119, 4410-85-L-119, NUDOCS 8506030283
Download: ML20128N457 (1)


Text

r e

GPU Nuclear Corporation Nuclear

=ome er8o s

Middletown, Pennsylvania 17057-0191 717 944-7621 TELEX 84 2386 Writer's Direct Dial Number:

(717) 948-8461 4410-85-L-0119 Document ID 0260A May 28,1985 TMI Program Office Attn: Dr. B. J. Snyder Program Director US Nuclear Regulatory Commission Washington, DC 20555

Dear Dr. Snyder:

Three Mile Island Nuclear Station, Unit 2 (TMI-2)

Operating License No. DPR-73 Docket No. 50-320 Technical Evaluation Report for the Defueling Water Cleanup System Per discussions with a member of your staff, attached is a revision to Section 3.2.2.4 of the Technical Evaluation Report (TER) for the Defueling Water Cleanup System.

The purpose of the attached revision is to correct and clarify the description of the low level alarm setpoints for the Fuel Tranfer Canal.

The System Description for the Fuel Transfer Canal / Spent Fuel Pool Cleanup System will be revised accordingly.

Sincerely M

85060302838505gg2O PDR ADOCK 0500 F. R. Standerfer PDR P

Vice President / Director, TMI-2 FRS/RDW/eml Attachment cc: Deputy Program Director - TMI Program Office, Dr. W. D. Travers 03 0

8 i GPU Nuclear Corporation is a subsidiary of the General Public Utilities Corporation i

J