CERTIFICATE OF COMPLIANCE U.S. NUCLEAR REGULATO FOR RADIOACTIVE MATERIALS PACKAGES h;
- l. a. Ct RTNCATE NLSIBER b REVISION NUMBER
- c. PACKAGE IDENTlHCATION NUMBER J PAGE NUMBER
- e. TOTAL NUMBER PAGES I l
j) 9033 11 USA /9033/B(U) 1 2
g
- 2. PREAMBLE k
- a. This certificate is ;ssued to certify that the packaging and contents described in item 5 below, meets the apphc Il l$
Code of federal Regulatsas, Part 71. 'Packagtng and Transportation of Radioactive Material."
lN
- b. This certificate does not reliese the consignor from comphance with any requirement of the regulations of the U k
19 apphtable regulatory agencies, including the governrnent of any country through or into which the package will be transport k,i j~
3 THis CERTlHCATE IS ISSUED ON THE BASIS OF A SARTY ANALYSIS REPORT OF THE PACKAGE DESI q
I
- a. ISSUED TO(Nams and Additio i
N
- b. TITLE AND IDFNTlHCATION OF REPORT OR APPLICATION:
k p
Amersham Corporation Amersham Corporation application dated E
l in 40 North Avenue September 24, 1993, as supplemented.
j a
l lg Burlington, MA 01803 l@n 4 CONerTIONS 4
p
- c. DOCxET NUMBER 71-9033 g
g g
This ceWficate is conditional upon fulfilhng the requirements of 10 CFR Part 7't, as applicable. and the cand.tions specified below E
N 5.
g ill e
l j
(a)
Packaging n
l (1)
Model No.: 660, 660E, 660A, 660AE, 660B or 660BE l
W il I g (2)
Description 4
g N
A steel encased uranium shielded Gamma Ray Projector.
Primary I
l5 components consist of an outer steel shell, polyurethane potting I
l 1f materit.1, uranium shield, "S" tube, and end plugs.
The contents are 8
8 securely positioned in the "S" tube by a source cable locking device E
and shipping plug. Tamper-proof seals are provided on the packaging.
8 The maximum total weight of the package is approximately 53 pounds.
(3)
Drawings N
5 The packaging is constructed in accordance with the following Technical i
u
'E Operations, Inc. Drawings:
E 1
s (i)
Model No. 6608 - Drawing No. 66025, Sheets 1, 2 and 3, Rev. F; i
E s
4 Ij (ii) Model No. 660 - Drawing No. 66025, Sheets 1, 2, 3, and 4, Rev. B; 6
L5 m;
or Drawing No. 66030, Sheets 1, 2, 3 and 4, Rev. -;
4 l'b y
l l
l5 (iii) Model No. 660A - Drawing No. 66030,' Sheets 1, 2 and 3, Rev. A; or E
l Drawing No. 66030, Sheets 1, 2, and 3, Rev. D.
E l
l9 i
Model Nos, with an E suffix have an electrical circuit.
E l>
l IB (b)
Contents 4
(1)
Type and form of material 19 lb Iridium-192 sources which meet the requirements of special form radioactive E
l9 material.
ip i!b W
ip a
l
'! II 9610160210 961009 4
,g 9
C PDR r
4 ammmmmmmmmmmmmmmmmmmmmmmmmmmmmmm=============md}E N
1
kTMwMWWWWWiiRiREridiiDi iiWWWWWWw a w a w w w w a--- - --- - ---
NRC FORM 418A cosmTioNs muumwo U.S. NUCLEAR REGULATORY COMMISSION
[f 8
Page 2 - Certificate No. 9033 - Revision No. 11 - Docket No. 71-9033 R:
$l(
k j
l?
l l9-5.
(b)
Contents (continued) lh
!T tt js-(2)
Maximum quantity of material per package
't ls#
6 (i) i I9.
140 Curies for the Model No. 660B or 660BE package.
6 lp (ii) 120 Curies for the Model No. 660, 660E, 660A or 660AE package.
t it g
I 6.
!n The source shall be secured in the shielded position of the packaging by the source g
assembly. The source assembly must be fabricated of materials capable of resisting l) g g
a 1475 *F fire environment for one-half hour and maintaining their positioning g
function. The source assembly must engage the locking device.
The source assembly q
lt g
must be of sufficient length and diameter to provide positive positioning of the in
{g source within the depleted uranium shield assembly, g
it g
ls 7.
The name plate must be-fabricated of materials capable of resisting the fire test jy) j of 10 CFR Part 71 and maintaining its legibility.
ik 9
lg 8.
In addition to the requirements of Subpart G of 10 CFR Part 71:
y la g
j (a)
The package must meet the Acceptance Test and Maintenance Program of Chapter l
9 8.0 of the application, as supplemented; and j
(b)
The package shall be prepared for shipment in accordance with the Operating l
Procedures in Chapter 7.0 of the application, as supplemented.
g g
[f9.
The package authorized by this certificate is hereby approved for use under general d
g license provisions of 10 CFR 971.12.
j 10.
Expiration date: October 31, 2000.
j g
REFERENCES II Amersham Corporation application dated September 24, 1993.
l l
Supplement dated: March 31, 1994; June 28, 1995.
Ih{
l#
Nordion International Inc. supplement dated August 19, 1996.
H) e lN E
- s FOR THE U.S. NUCLEAR REGULATORY COMMISSION
'E t
l#
l#
Cass R. Chappell, Chief Package Certification Section l#
Spent Fuel Project Office Office of Nuclear Material Safety g gg and Safeguards IN Date:
lb j6 Ib
- t
!E b......,................,..,.....,,====,........M
e p@ M%g
.jh 4
UNITED STATES g
j NUCLEAR REGULATORY COMMISSIC 1 o
WASHINGTON, D.C. 2066M201 APPROVAL RECORD Model No. 660 Series Packages Certificate of Compliance No. 9033 Revision No. 11 By application dated August 19, 1996, Nordion International Inc. requested an amendment to Certificate of Compliance No. 9033, for the Model No. 660 series packages.
The applicant requested that the certificate be revised to include the Nordion Model C-337 source assembly, or alternately, that generic source assemblies be authorized.
The certificate is being revised to delete reference to specific source assembly models.
criteria for source assemblies, remain in effect.All other conditions in the ce The changes to the meet the requiremen. certificate do not affect the ability of the packages to ts of 10 CFR Part 71, o+4 Cass R. Chappell, Chief Package Certification Section Spent Fuel Project Office Office of Nuclear Material Safety g gg and Safeguards Date
.