ML20128M688

From kanterella
Jump to navigation Jump to search
Final Deficiency Rept SD-76 Re Load Indicating Washers Supplied by Cooper & Turner,Inc.Initially Reported on 850318.Washers in Question Differ from Other Washers Only in Appearance.Washers Not Detrimental
ML20128M688
Person / Time
Site: Millstone 
Issue date: 05/17/1985
From: Opeka J
NORTHEAST NUCLEAR ENERGY CO., NORTHEAST UTILITIES
To: Murley T
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
F0757A, F757A, SD-76, SP-76, NUDOCS 8506030053
Download: ML20128M688 (2)


Text

.

c k*

General Offices e Selden Street, Berlin, Connecticut v.e cm ececur uc.* = m== cowa=

N. car.u [,(($,,,,

HARTFORD. CONNECTICUT 06141-0270 J

se.uu.a ein=,ca.

(203) 665-5000 May 17,1985 Docket No. 50-423 F0757A Dr. Thomas E. Murley Regional Administrator U.S. Nuclear Regulatory Commission Region I 631 Park Avenue King of Prussia, PA 19406

Reference:

(1)

W. G. Counsil letter to T. E. Murley, F0723A, dated April 17, 1985.

Dear Dr. Murley:

Millstone Nuclear Power Station, Unit No. 3 Reporting of Potential Significant Deficiencies in Accordance with 10CFR50.55(e):

Cooper and Turner Load Indicating Washers (SD-76)

In a March 18,1985 telephone conversation between your Mr. T. Rebelowski and our Mr. R. B. Roy, Northeast Nuclear Energy Company reported a potential significant deficiency in the construction of Millstone Unit No. 3 in accordance with 10CFR50.55(e).

The potential significant deficiency involved load indicating washers (LIW) supplied by Cooper and Turner, Inc.

A certain lot of Cooper and Turner LIW were thought to have preloads out of compliance with their design values. A deficiency in these LIW could result in inadequate bolt preloading which could compromise the integrity of the structural connection.

In P,eference (1), we informed you that we were still investigating the Cooper and Turner claim that some of their LIW may have been improperly heat treated af ter leaving their facility. We have completed our review of this claim and do not find it to be credible. An investigation by our architect-engineer, Stone &

Webster Engineering Corporation, along with testing performed by Bridgeport Laboratories has lead us to determine that the LIW in question differ from other Cooper and Turner LIW only in appearance (the potentially deficient LIW were lighter in color). The LIW in question had approximately the same hardness and showed no significant variations in crushing loads when compared to other Cooper and Turner LIW. Therefore, there is no reason to suspect that these washers may be detrimental to the performance of structural joints and this is not a significant deficiency for Millstone Unit No. 3.

8506030053 050517 PDR ADOCK 05000423 S

PDR i0 d

.o O

,4;

, We consider this' to be our. final report for SD-76. We trust that the above information satisfactorily responds to your concerns.