ML20128M011
ML20128M011 | |
Person / Time | |
---|---|
Site: | 07001113 |
Issue date: | 02/25/1985 |
From: | Earnestine Clay, Mcalpine E NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II) |
To: | |
Shared Package | |
ML19304B358 | List: |
References | |
70-1113-85-03, 70-1113-85-3, NUDOCS 8507250170 | |
Download: ML20128M011 (1) | |
Similar Documents at 07001113 | |
---|---|
Category:INSPECTION REPORT
MONTHYEARML20216F1281999-09-0808 September 1999
[Table view]Insp Rept 70-1113/99-05 on 990809-13.No Violations Noted. Major Areas Inspected:Rountine Unannounced Insp Involved Observation of Work Activities,Review of Selected Records ML20211L3001999-08-31031 August 1999 Insp Rept 70-1113/99-04 on 990726-0805.No Violations Noted. Major Areas Inspected:Plant Operations,Mgt Organization & Controls,Maint/Surveillance & Emergency Preparedness ML20211F2551999-08-25025 August 1999 Insp Rept 70-1113/99-202 on 990802-06.No Violations Noted. Major Areas Inspected:Implementation of GE Fire Protection Program Commitments Re Safe Plant Operations ML20210V2051999-08-13013 August 1999 Insp Rept 70-1113/99-03 on 990712-16.No Violations Noted. Major Areas Inspected:Environ Monitoring Program ML20195D4131999-06-0404 June 1999 Partially Withheld Insp Rept 70-1113/99-201 Conducted on 990510-14.No Violations Noted.Details Withheld,Per 10CFR2.790 ML20203G4671999-02-0505 February 1999 Insp Rept 70-1113/99-01 on 990111-15.No Violations Noted. Major Areas Inspected:Observation of Work Activities,Review of Selected Records & Interviews with Personnel in Area of Radiation Protection ML20202J1001999-01-29029 January 1999 Insp Rept 70-1113/99-02 on 990104-08.No Violations Noted. Major Areas Inspected:Plant Operations,Environ Protection & Training ML20155A8561998-09-30030 September 1998 Insp Rept 70-1113/98-05 on 980908-10.No Violations Noted. Major Areas Inspected:Licensee Program for Security & Safeguards ML20154C3421998-09-11011 September 1998 Insp Rept 70-1113/98-03 on 980817-21.No Violations Noted. Major Areas Inspected:Evaluation of Licensee Conduct of Transportation Program for Radioactive Matls & Radioactive Waste Mgt Program ML20154C1651998-09-0404 September 1998 Insp Rept 70-1113/98-04 on 980810-14.No Violations Noted. Major Areas Inspected:Assessment of Licensee Emergency Preparedness Program & State of Readiness for Responding to Various Postulated Accidents ML20151S8091998-09-0303 September 1998 Partially Withheld Insp Rept 70-1113/98-204 on 980810-14. Details Withheld (Ref 10CFR2.790) ML20237B4241998-08-0707 August 1998 Insp Rept 70-1113/98-02 on 980713-17.No Violations Noted. Major Areas Inspected:Evaluation of Licensee Conduct of Plant Operations,Mgt Controls & Environ Protection Program ML20247H9921998-05-14014 May 1998 Insp Rept 70-1113/98-202 on 980420-24.Noncited Violation Noted.Major Areas Inspected:Implementation of GE Fire Protection Program ML20247H8581998-05-13013 May 1998 Insp Rept 70-1113/98-203 on 950504-08.Noncited Violations Noted.Major Areas Inspected:Review of Adequacy of Licensee Criticality Safety Program ML20216D3001998-04-0808 April 1998 Partially Withheld Insp Rept 70-1113/98-201 on 980309-13. No Violations Identified.Details Withheld Per 10CFR2.790 ML20217G1081998-03-26026 March 1998 Insp Rept 70-1113/98-01 on 980223-27.Violations Noted. Major Areas Inspected:Evaluation of Licensee Conduct of Plant Operations & Training ML20199B4051998-01-0606 January 1998 Insp Rept 70-1113/97-08 on 971208-12.No Violations Noted. Major Areas Inspected:Licensee Conduct of Plant Operations & Maint ML20198H4351997-09-0404 September 1997 Partially Withheld Insp Rept 70-1113/97-203 on 970811-15, Per 10CFR2.790 ML20216B1821997-08-29029 August 1997 Insp Rept 70-1113/97-07 on 970714-18.No Violations Noted. Major Areas Inspected:Safety Operations,Radioactive Solid Waste Mgt,Transportation & Emergency Preparedness ML20141J7671997-08-11011 August 1997 Insp Rept 70-1113/97-06 on 970623-27.No Violations Noted. Major Areas Inspected:Status of Dry Conversion Facility, Including Completion of Const,Nuclear Criticality Safety, Chemical Safety & Radiation Protection ML20140E6571997-06-0606 June 1997 Insp Rept 70-1113/97-04 on 970326-28,0407-11 & 0429-0509. No Violations Noted.Major Areas Inspected:Status of New Dry Conversion Facility,Including Operations & Completion of Const ML20141K7021997-05-16016 May 1997 Insp Rept 70-1113/97-05 on 970414-18.No Violations Noted. Major Areas Inspected:Rp & FP Programs ML20138J8401997-04-18018 April 1997 Insp Rept 70-1113/97-03 on 970323-27.No Violations Noted. Major Areas Inspected:Environ Protection & Waste Mgt Programs & Status of New Dry Conversion Facility ML20137T5471997-04-0808 April 1997 Insp Rept 70-1113/97-02 on 970303-07 & 17-21.No Violations Noted.Major Areas Inspected:Operations,Training,Construction Completion & Training & Functional Testing of Sys ML20137P8141997-03-0707 March 1997 Insp Rept 70-1113/97-201 on 970303-07.Violation Noted.Rept Details Withheld ML20217D7331997-02-27027 February 1997 Insp Rept 70-1113/97-01 on 970127-31.No Violations Noted. Major Areas Inspected:Plant Operations,Management Organization & Controls,Maintenance/Surveillance,Training & Dcf Project ML20134G9851997-01-28028 January 1997 Special Insp Team Rept 70-1113/96-12 on 961204-08.Violations Noted.Major Areas Inspected:Circumstances Surrounding Tube Failure,Precursors to Event & Response to Event ML20134Q3121996-11-13013 November 1996 Insp Rept 70-1113/96-11 on 961014-18.No Violations Noted. Major Areas Inspected:Plant Operations,Mgt Organization & Control,Maint/Surveillance & Dcf Project ML20134J4071996-11-0606 November 1996 Insp Rept 70-1113/96-10 on 960930-1003.Violations Noted. Major Areas Inspected:Elements of Internal Dose Monitoring & Controls Program Including Activities in Urinalysis Bioassy & Associated Air Sampling Program ML20134C4891996-09-0909 September 1996 Insp Rept 70-1113/96-07 on 960805-09.No Violations Noted. Major Areas Inspected:Review of Listed Physics Program Elements,Independent Radiation Safety Audit,External & Internal Exposure Controls & Organizational Change ML20058P6741993-12-0808 December 1993 Insp Rept 70-1113/93-11 on 931115-19.Non-cited Violations Identified.Major Areas Inspected:Mgt Controls,Organization, Nuclear Criticality Safety,Facility Changes,Maintenance, Operations & NRC Bulletins & Notices ML20058P5011993-12-0303 December 1993 Insp Rept 70-1113/93-10 on 931025-29 & 1101-05.No Violations Noted.Major Areas Inspected:Evaluation of Fuel Processing in Selected Favorable Geometry Operations & Nuclear Criticality Safety Aspects of Modifications Made to Conversion Lines ML20058Q2071993-10-17017 October 1993 Insp Rept 70-1113/93-09 on 930913-17.No Violations Noted. Major Areas Inspected:Licensee Radiation Protection Program Including Program Organization & Staffing,Procedures & Program Changes & Training ML20057E7331993-09-30030 September 1993 Insp Rept 70-1113/93-08 on 930907-10.No Violations or Deviations Noted.Major Areas Inspected:Emergency Preparedness & Which Included Listed Program Elements ML20057C1271993-09-20020 September 1993 Insp Rept 70-1113/93-202 on 930816-20.No Violations Noted. Major Areas Inspected:Mc&A Sys Mgt & Assessment. Proprietary Insp Rept Details Withheld ML20057C2901993-09-15015 September 1993 Insp Rept 70-1113/93-07 on 930830-0903.No Violations or Deviations Noted.Major Areas Inspected:Nuclear Criticality Safety,Operations,Fire Protection,Facility Changes & NRC Bulletins & Notices ML20056E2851993-08-12012 August 1993 Insp Rept 70-1113/93-06 on 930726-30.No Violations Noted. Major Areas Inspected:Mgt Controls,Nuclear Criticality Safety,Maint & Fire Protection ML20056F3711993-08-10010 August 1993 Insp Rept 70-1113/93-05 on 930712-16.No Violations Noted. Major Areas Inspected:Radioactive Effluents,Environ Protection & Transportation of Radioactive Matl ML20128G4351993-02-0202 February 1993 Insp Rept 70-1113/93-01 on 930111-15.No Violations or Deviations Noted.Major Areas Inspected:Mgt Controls,Facility Changes,Facility Operations & follow-up of Previously Identified Items ML20128C9151992-11-23023 November 1992 Insp Rept 70-1113/92-17 on 921109-13.No Violations or Deviations Noted.Major Areas Inspected:Mgt Controls,Facility Operations,Facility Changes,Followup on Previously Identified Items & Current Issues ML20128C0081992-11-23023 November 1992 Insp Rept 70-1113/92-15 on 921013-16.No Violations Noted. Major Areas Inspected:Emergency Facilities,Equipment & Implementing Procedures & Coordination of Emergency Planning W/Offsite Support Agencies ML20062H4231990-11-19019 November 1990 Insp Rept 70-1113/90-11 on 900924-28.No Violations or Deviations Noted.Major Areas Inspected:Nuclear Criticality Safety,Operations Review & Followup on 10CFR21 Reportable Items ML20059N3391990-09-28028 September 1990 Insp Rept 70-1113/90-08 on 900827-31.No Violations or Deviations Noted.Major Areas Inspected:Radwaste Mgt, Radioactive Effluent Sampling,Monitoring & Analysis & Radiological Environ Monitoring ML20246C0641989-08-0909 August 1989 Partially Withheld Insp Rept 70-1113/89-10 on 890718-19 (Ref 10CFR2.790).Violations Re Controlled Access Area Noted But Not Cited.Major Areas Inspected:Physical Protection of Low Enriched Nuclear Matl ML20245E6791989-08-0303 August 1989 Partially Withheld Insp Rept 70-1113/89-09 on 890626-30 (Ref 10CFR2.790 & 73.21).No Violations or Deviations Noted. Major Areas Inspected:Mc&A Sys Mgt & Assessment,Internal Controls,Measurement Sys & Measurement Controls ML20248C1411989-07-27027 July 1989 Insp Rept 70-1113/89-05 on 890522-26 & 0612-15.Violations Noted.Major Areas Inspected:Licensee Radiation Protection Programs for Assuring Personnel Exposures Maintained ALARA, & Review of Previously Identified Inspector Followup Items ML20246E7181989-06-29029 June 1989 Insp Rept 70-1113/89-06 on 890605-09.No Violations & Deviations Noted.Major Areas Inspected:Emergency Preparedness,Radiological Contingency & Emergency Plan.Two Drill Weaknesses Identified ML20246C0611989-06-27027 June 1989 Insp Rept 70-1113/89-08 on 890530-0602.No Violations or Deviations Noted.Major Areas Inspected:Nuclear Criticality Safety,Operations Review,Maint & Surveillance Testing ML20244D8301989-05-25025 May 1989 Insp Rept 70-1113/89-04 on 890424-28.Non-cited Violation Identified.No Deviations Noted.Major Areas Inspected: Radwaste Mgt,Radioactive Effluent Sampling,Monitoring & Analysis & Radiological Environ Monitoring ML20246J7991989-05-0404 May 1989 Insp Rept 70-1113/89-03 on 890327-31.No Violations or Deviations Noted.Major Areas Inspected:Previously Identified Fire Protection/Prevention Program Findings from Oct 1986 Operational Safety Assessment Insp 1999-09-08 Category:MANUFACTURER/VENDOR/ENGINEER MONTHYEARML20059N3391990-09-28028 September 1990
[Table view]Insp Rept 70-1113/90-08 on 900827-31.No Violations or Deviations Noted.Major Areas Inspected:Radwaste Mgt, Radioactive Effluent Sampling,Monitoring & Analysis & Radiological Environ Monitoring ML20246C0641989-08-0909 August 1989 Partially Withheld Insp Rept 70-1113/89-10 on 890718-19 (Ref 10CFR2.790).Violations Re Controlled Access Area Noted But Not Cited.Major Areas Inspected:Physical Protection of Low Enriched Nuclear Matl ML20245E6791989-08-0303 August 1989 Partially Withheld Insp Rept 70-1113/89-09 on 890626-30 (Ref 10CFR2.790 & 73.21).No Violations or Deviations Noted. Major Areas Inspected:Mc&A Sys Mgt & Assessment,Internal Controls,Measurement Sys & Measurement Controls ML20248C1411989-07-27027 July 1989 Insp Rept 70-1113/89-05 on 890522-26 & 0612-15.Violations Noted.Major Areas Inspected:Licensee Radiation Protection Programs for Assuring Personnel Exposures Maintained ALARA, & Review of Previously Identified Inspector Followup Items ML20246E7181989-06-29029 June 1989 Insp Rept 70-1113/89-06 on 890605-09.No Violations & Deviations Noted.Major Areas Inspected:Emergency Preparedness,Radiological Contingency & Emergency Plan.Two Drill Weaknesses Identified ML20246C0611989-06-27027 June 1989 Insp Rept 70-1113/89-08 on 890530-0602.No Violations or Deviations Noted.Major Areas Inspected:Nuclear Criticality Safety,Operations Review,Maint & Surveillance Testing ML20246J7991989-05-0404 May 1989 Insp Rept 70-1113/89-03 on 890327-31.No Violations or Deviations Noted.Major Areas Inspected:Previously Identified Fire Protection/Prevention Program Findings from Oct 1986 Operational Safety Assessment Insp ML20247F0161989-03-10010 March 1989 Insp Rept 70-1113/89-02 on 890123-27.No Violations or Deviations Noted.Major Areas Inspected:Mgt Organization Controls,Training & Retraining,Nuclear Criticality Safety, Operations Review,Maint & Surveillance Testing ML20247M6541989-03-0808 March 1989 Partially Withheld Insp Rept 70-1113/89-01 on 890109-13 (Ref 10CFR2.790 & 73.21).No Violations or Deviations Noted.Major Areas Inspected:Measurement Sys & Matl Control & Accountability Sys Mgt & Assessment ML20206B4491988-11-0707 November 1988 Insp Rept 70-1113/88-17 on 880926-30.Violations & Deviations Noted.Major Areas Inspected:Radwaste Mgt & Radiological Environ Monitoring ML20206C2761988-10-28028 October 1988 Partially Withheld Team Insp Rept 70-1113/88-13 on 880926-30 (Ref 10CFR2.790).One Violation Noted.Major Areas Inspected: Licensee Nuclear Matl Control & Accounting Program Used to Achieve Performance Objectives for Period Ending 880801 ML20195C1581988-10-19019 October 1988 Insp Rept 70-1113/88-16 on 880919-22.No Violations or Deviations Noted.Major Areas Inspected:Mgt Organization & Controls,Training,Nuclear Criticality Safety & Operations ML20195C0111988-10-18018 October 1988 Insp Rept 70-1113/88-15 on 880919-23.No Violations or Deviations Noted.Major Areas Inspected:Emergency Preparedness ML20155B9121988-09-28028 September 1988 Partially Withheld Insp Rept 70-1113/88-12 on 880822-26. Violations Noted.Major Areas Inspected:Export Shipments & Measurements ML20154A8391988-08-29029 August 1988 Partially Withheld Insp Rept 70-1113/88-11 on 880725-0802 (Ref 10CFR2.790).No Deviations or Violations Noted.Major Ares Inspected:Physical Inventory,Independent Insp Effort & Actions on Previous Findings ML20151S4481988-07-27027 July 1988 Insp Rept 70-1113/88-08 on 880523-27.Violations Noted.Major Areas Inspected:Radiation Protection Program Areas,Including Radiation Protection Staff Organization & Training,Solid Radwaste Issues & Transportation Activities ML20154N6231988-05-18018 May 1988 Insp Rept 70-1113/88-06 on 880411-15.No Violations or Deviations Noted.Major Areas Inspected:Radwaste Mgt & Radiological Environ Monitoring ML20151V3321988-04-19019 April 1988 Partially Withheld Insp Rept 70-1113/88-03 on 880314-18 (Ref 10CFR2.790 & 73.21).No Violations or Deviations Noted.Major Areas Inspected:Implementation of Us/Iaea Agreement at GE Fuel Fabrication Facility ML20151P2311988-04-15015 April 1988 Partially Withheld Insp Rept 70-1113/88-05 on 880328-30 Ref (10CFR2.790(d) & 73.21).No Violations or Deviations Noted.Allegation Could Not Be Substantiated ML20236R6281987-11-16016 November 1987 Revised Page 9 to Insp Rept 70-1113/87-12 ML20236E4301987-10-16016 October 1987 Partially Withheld Insp Rept 70-1113/87-14 on 870908-28 (Ref 10CFR2.790(d)).No Violations or Deviations Noted.Major Areas Inspected:Statistical Analysis of U Concentration Measurements of U Dioxide Powder by Util & NRC Contractor ML20235F4141987-09-18018 September 1987 Insp Rept 70-1113/87-12 on 870824-28.No Violations or Deviations Noted.Major Areas Inspected:Radwaste Mgt,Environ Monitoring & Confirmatory Measurements ML20235H4571987-07-0707 July 1987 Insp Rept 70-1113/87-08 on 870608-12.Major Areas Inspected: Radiation Protection Program,Transportation of Radioactive Matls,Solid Radwaste Mgt,Followup of Previous Enforcement Issues,Allegations & IE Info Notices ML20235M1131987-06-30030 June 1987 Partially Withheld Insp Rept 70-1113/87-09 on 870615-18 (Ref 10CFR2.790 & 73.21).No Violations Noted.Major Areas Inspected:Followup on Inspector Identified Items,Facility Organization & Mgt Controls & Measurement Sys ML20214T7921987-05-29029 May 1987 Partially Withheld Insp Rept 70-1113/87-05 on 870504-08 (Ref 10CFR2.790(d) & 73.21).Violation Noted:Failure to Properly Approve Procedure Prior to Use ML20214W1081987-05-22022 May 1987 Partially Withheld Insp Rept 70-1113/87-07 on 870427-30 (Ref 10CFR2.790 & 73.21).No Violations or Deviations Noted.Major Areas Inspected:Exam of Measurement Differences Between GE & New Brunswick Lab Associated w/UO2 Powder ML20209E1571987-04-22022 April 1987 Partially Withheld Insp Rept 70-1113/87-04 on 870323-27 (Ref 10CFR2.790 & 73.21).No Violation or Deviation Noted.Major Areas Inspected:Investigation of GE UO2 Powder Measurements ML20209E1001987-04-0909 April 1987 Partially Withheld Insp Rept 70-1113/87-03 on 870316-20 (Ref 10CFR2.790 & 73.21).No Violations or Deviations Noted. Major Areas Inspected:Followup on Inspector Identified Items & Measurement Control & Statistics ML20207T7341987-02-17017 February 1987 Partially Withheld Insp Rept 70-1113/87-01 on 870112-16 (Ref 10CFR2.790 & 73.21).No Violations or Deviations Noted.Major Areas Inspected:Measurement Sys,Facility Organization & Mgt Controls ML20211C7391987-02-10010 February 1987 Partially Withheld Insp Rept 70-1113/87-02 on 870120-23 (Ref 10CFR2.790 & 73.21).No Violations or Deviations Noted. Major Areas Inspected:Measurements & Independent Insp Effort ML20214W9871986-11-26026 November 1986 Partially Withheld Insp Rept 70-1113/86-23 on 861014-17 (Ref 10CFR2.790 & 73.21).No Violations or Deviations Noted.Major Areas Inspected:Measurement Sys & Followup on Previous Violations & Insp Findings ML20207A8831986-10-29029 October 1986 Insp Rept 70-1113/86-19 on 860929-1003.Violations Noted: Failure to Follow Procedures,Failure to Calibr Airline Pressure Gauges or Flow Measuring Devices & Failure to Meet DOT Empty Radioactive Matl Package Shipping Requirements ML20197A7691986-10-0909 October 1986 Insp Rept 70-1113/86-18 on 860926.No Violations or Deviations Noted.Major Areas Inspected:Selected Areas of Emergency Preparedness Program ML20205E0941986-08-0606 August 1986 Partially Withheld Insp Rept 70-1113/86-16 on 860721-25 (Ref 10CFR2.790 & 73.21).Violation Noted:Failure to Submit Matl Status Rept ML20211N0431986-08-0505 August 1986 Partially Withheld Insp Rept 70-1113/86-16 on 860721-25 (Ref 10CFR2.790(d) & 73.21).Violation Noted:Failure to Submit Matl Status Rept ML20211M9841986-07-30030 July 1986 Partially Withheld Insp Rept 70-1113/86-15 on 860714-18 (Ref 10CFR2.790(d) & 73.21).Violation Noted:Failure to Follow Approved Plant Procedures ML20207K4371986-07-14014 July 1986 Partially Withheld Insp Rept 70-1113/86-13 on 860630-0702 (Ref 10CFR2.790).No Violation Noted.Major Areas Inspected: Licensee Program for Physical Protection of SNM of Low Strategic Significance ML20211N8691986-07-14014 July 1986 Physical Security Insp Rept 70-1113/86-13 on 860630-0702. No Violations Noted.Major Areas Inspected:Licensee Program for Physical Protection of SNM of Low Strategic Significance ML20199J3761986-06-17017 June 1986 Insp Rept 70-1113/86-11 on 860602-06.No Noncompliance Noted. Major Areas Inspected:Measurements,Export Shipment & Followup on Previous Insp Findings.Details Withheld (Ref 10CFR2.790) ML20211M9061986-06-17017 June 1986 Partially Withheld Insp Rept 70-1113/86-11 on 860602-06 (Ref 10CFR2.790(d) & 73.21).No Violations or Deviations Noted.Major Areas Inspected:Measurements,Export Shipment & Followup on Previous Insp Findings ML20211M8561986-06-0303 June 1986 Partially Withheld Insp Rept 70-1113/86-09 on 860428-0502 (Ref 10CFR2.790(d) & 73.21).Violation Noted:Failure to Correctly Calculate Limit of Error Associated W/Inventory Difference ML20205P7791986-04-28028 April 1986 Partially Withheld Insp Rept 70-1113/86-07 on 860324-28 (Ref 10CFR2.790 & 73.21).No Violations or Deviations Noted. Major Areas Inspected:Export Shipment,Measurements & Followup on Previous Insp Findings ML20211M7911986-04-28028 April 1986 Partially Withheld Details of Insp Rept 70-1113/86-07 on 860324-28 (Ref 10CFR2.790(d) 73.21).No Violations or Deviations Noted.Major Areas Inspected:Export Shipmment, Measurements & Followup on Previous Insp Findings ML20203P1091986-04-25025 April 1986 Insp Rept 70-1113/86-08 on 860408.No Violations or Deviations Identified.Major Areas Inspected:Confirmatory Radiation & Contamination Surveys Performed as Closeout Insp of Storage Facility Leased by Eastern Distribution,Inc ML20203N9271986-04-10010 April 1986 Partially Withheld Insp Rept 70-1113/86-05 on 860317-21 (Ref 10CFR73.21 & 2.790).No Violation or Deviation Noted. Major Areas Inspected:Facility Operations & Internal Controls,Records & Repts ML20141E4731986-04-0808 April 1986 Partially Withheld Insp Rept 70-1113/86-06 on 860317-21 (Ref 10CFR2.790 & 73.21).No Violation Noted.Major Areas Inspected:Measurement Control & Statistics ML20211M7561986-04-0808 April 1986 Partially Withheld Insp Rept 70-1113/86-06 on 860317-21 (Ref 10CFR2.790(d) & 73.21).No Violations or Deviations. Major Areas Inspected:Measurement Control & Statistics & Licensee Action on Previously Identified Violations ML20155A0191986-03-31031 March 1986 Insp Rept 70-1113/86-03 on 860218-21.No Violations or Deviations Noted.Major Areas Inspected:Followup on Conversion Reactor Event,Nuclear Criticality Safety, Operations Review & Procedures Re UF6 Cylinders ML20205M2031986-03-28028 March 1986 Insp Rept 70-1113/86-02 on 860224-28.No Violation or Deviation Noted.Major Areas Inspected:Emergency Preparedness ML20205M5531986-03-27027 March 1986 Insp Rept 70-1113/86-01 on 860203-05.Violations Noted:Eight HEPA Filters Improperly Installed,Resulting in Degradation of Rated Efficiency of Gaseous Effluent Treatment Sys & Failure to Approve Transportation Procedures 1990-09-28 Category:INSPECTION REPORT MONTHYEARML20216F1281999-09-0808 September 1999
[Table view]Insp Rept 70-1113/99-05 on 990809-13.No Violations Noted. Major Areas Inspected:Rountine Unannounced Insp Involved Observation of Work Activities,Review of Selected Records ML20211L3001999-08-31031 August 1999 Insp Rept 70-1113/99-04 on 990726-0805.No Violations Noted. Major Areas Inspected:Plant Operations,Mgt Organization & Controls,Maint/Surveillance & Emergency Preparedness ML20211F2551999-08-25025 August 1999 Insp Rept 70-1113/99-202 on 990802-06.No Violations Noted. Major Areas Inspected:Implementation of GE Fire Protection Program Commitments Re Safe Plant Operations ML20210V2051999-08-13013 August 1999 Insp Rept 70-1113/99-03 on 990712-16.No Violations Noted. Major Areas Inspected:Environ Monitoring Program ML20195D4131999-06-0404 June 1999 Partially Withheld Insp Rept 70-1113/99-201 Conducted on 990510-14.No Violations Noted.Details Withheld,Per 10CFR2.790 ML20203G4671999-02-0505 February 1999 Insp Rept 70-1113/99-01 on 990111-15.No Violations Noted. Major Areas Inspected:Observation of Work Activities,Review of Selected Records & Interviews with Personnel in Area of Radiation Protection ML20202J1001999-01-29029 January 1999 Insp Rept 70-1113/99-02 on 990104-08.No Violations Noted. Major Areas Inspected:Plant Operations,Environ Protection & Training ML20155A8561998-09-30030 September 1998 Insp Rept 70-1113/98-05 on 980908-10.No Violations Noted. Major Areas Inspected:Licensee Program for Security & Safeguards ML20154C3421998-09-11011 September 1998 Insp Rept 70-1113/98-03 on 980817-21.No Violations Noted. Major Areas Inspected:Evaluation of Licensee Conduct of Transportation Program for Radioactive Matls & Radioactive Waste Mgt Program ML20154C1651998-09-0404 September 1998 Insp Rept 70-1113/98-04 on 980810-14.No Violations Noted. Major Areas Inspected:Assessment of Licensee Emergency Preparedness Program & State of Readiness for Responding to Various Postulated Accidents ML20151S8091998-09-0303 September 1998 Partially Withheld Insp Rept 70-1113/98-204 on 980810-14. Details Withheld (Ref 10CFR2.790) ML20237B4241998-08-0707 August 1998 Insp Rept 70-1113/98-02 on 980713-17.No Violations Noted. Major Areas Inspected:Evaluation of Licensee Conduct of Plant Operations,Mgt Controls & Environ Protection Program ML20247H9921998-05-14014 May 1998 Insp Rept 70-1113/98-202 on 980420-24.Noncited Violation Noted.Major Areas Inspected:Implementation of GE Fire Protection Program ML20247H8581998-05-13013 May 1998 Insp Rept 70-1113/98-203 on 950504-08.Noncited Violations Noted.Major Areas Inspected:Review of Adequacy of Licensee Criticality Safety Program ML20216D3001998-04-0808 April 1998 Partially Withheld Insp Rept 70-1113/98-201 on 980309-13. No Violations Identified.Details Withheld Per 10CFR2.790 ML20217G1081998-03-26026 March 1998 Insp Rept 70-1113/98-01 on 980223-27.Violations Noted. Major Areas Inspected:Evaluation of Licensee Conduct of Plant Operations & Training ML20199B4051998-01-0606 January 1998 Insp Rept 70-1113/97-08 on 971208-12.No Violations Noted. Major Areas Inspected:Licensee Conduct of Plant Operations & Maint ML20198H4351997-09-0404 September 1997 Partially Withheld Insp Rept 70-1113/97-203 on 970811-15, Per 10CFR2.790 ML20216B1821997-08-29029 August 1997 Insp Rept 70-1113/97-07 on 970714-18.No Violations Noted. Major Areas Inspected:Safety Operations,Radioactive Solid Waste Mgt,Transportation & Emergency Preparedness ML20141J7671997-08-11011 August 1997 Insp Rept 70-1113/97-06 on 970623-27.No Violations Noted. Major Areas Inspected:Status of Dry Conversion Facility, Including Completion of Const,Nuclear Criticality Safety, Chemical Safety & Radiation Protection ML20140E6571997-06-0606 June 1997 Insp Rept 70-1113/97-04 on 970326-28,0407-11 & 0429-0509. No Violations Noted.Major Areas Inspected:Status of New Dry Conversion Facility,Including Operations & Completion of Const ML20141K7021997-05-16016 May 1997 Insp Rept 70-1113/97-05 on 970414-18.No Violations Noted. Major Areas Inspected:Rp & FP Programs ML20138J8401997-04-18018 April 1997 Insp Rept 70-1113/97-03 on 970323-27.No Violations Noted. Major Areas Inspected:Environ Protection & Waste Mgt Programs & Status of New Dry Conversion Facility ML20137T5471997-04-0808 April 1997 Insp Rept 70-1113/97-02 on 970303-07 & 17-21.No Violations Noted.Major Areas Inspected:Operations,Training,Construction Completion & Training & Functional Testing of Sys ML20137P8141997-03-0707 March 1997 Insp Rept 70-1113/97-201 on 970303-07.Violation Noted.Rept Details Withheld ML20217D7331997-02-27027 February 1997 Insp Rept 70-1113/97-01 on 970127-31.No Violations Noted. Major Areas Inspected:Plant Operations,Management Organization & Controls,Maintenance/Surveillance,Training & Dcf Project ML20134G9851997-01-28028 January 1997 Special Insp Team Rept 70-1113/96-12 on 961204-08.Violations Noted.Major Areas Inspected:Circumstances Surrounding Tube Failure,Precursors to Event & Response to Event ML20134Q3121996-11-13013 November 1996 Insp Rept 70-1113/96-11 on 961014-18.No Violations Noted. Major Areas Inspected:Plant Operations,Mgt Organization & Control,Maint/Surveillance & Dcf Project ML20134J4071996-11-0606 November 1996 Insp Rept 70-1113/96-10 on 960930-1003.Violations Noted. Major Areas Inspected:Elements of Internal Dose Monitoring & Controls Program Including Activities in Urinalysis Bioassy & Associated Air Sampling Program ML20134C4891996-09-0909 September 1996 Insp Rept 70-1113/96-07 on 960805-09.No Violations Noted. Major Areas Inspected:Review of Listed Physics Program Elements,Independent Radiation Safety Audit,External & Internal Exposure Controls & Organizational Change ML20058P6741993-12-0808 December 1993 Insp Rept 70-1113/93-11 on 931115-19.Non-cited Violations Identified.Major Areas Inspected:Mgt Controls,Organization, Nuclear Criticality Safety,Facility Changes,Maintenance, Operations & NRC Bulletins & Notices ML20058P5011993-12-0303 December 1993 Insp Rept 70-1113/93-10 on 931025-29 & 1101-05.No Violations Noted.Major Areas Inspected:Evaluation of Fuel Processing in Selected Favorable Geometry Operations & Nuclear Criticality Safety Aspects of Modifications Made to Conversion Lines ML20058Q2071993-10-17017 October 1993 Insp Rept 70-1113/93-09 on 930913-17.No Violations Noted. Major Areas Inspected:Licensee Radiation Protection Program Including Program Organization & Staffing,Procedures & Program Changes & Training ML20057E7331993-09-30030 September 1993 Insp Rept 70-1113/93-08 on 930907-10.No Violations or Deviations Noted.Major Areas Inspected:Emergency Preparedness & Which Included Listed Program Elements ML20057C1271993-09-20020 September 1993 Insp Rept 70-1113/93-202 on 930816-20.No Violations Noted. Major Areas Inspected:Mc&A Sys Mgt & Assessment. Proprietary Insp Rept Details Withheld ML20057C2901993-09-15015 September 1993 Insp Rept 70-1113/93-07 on 930830-0903.No Violations or Deviations Noted.Major Areas Inspected:Nuclear Criticality Safety,Operations,Fire Protection,Facility Changes & NRC Bulletins & Notices ML20056E2851993-08-12012 August 1993 Insp Rept 70-1113/93-06 on 930726-30.No Violations Noted. Major Areas Inspected:Mgt Controls,Nuclear Criticality Safety,Maint & Fire Protection ML20056F3711993-08-10010 August 1993 Insp Rept 70-1113/93-05 on 930712-16.No Violations Noted. Major Areas Inspected:Radioactive Effluents,Environ Protection & Transportation of Radioactive Matl ML20128G4351993-02-0202 February 1993 Insp Rept 70-1113/93-01 on 930111-15.No Violations or Deviations Noted.Major Areas Inspected:Mgt Controls,Facility Changes,Facility Operations & follow-up of Previously Identified Items ML20128C9151992-11-23023 November 1992 Insp Rept 70-1113/92-17 on 921109-13.No Violations or Deviations Noted.Major Areas Inspected:Mgt Controls,Facility Operations,Facility Changes,Followup on Previously Identified Items & Current Issues ML20128C0081992-11-23023 November 1992 Insp Rept 70-1113/92-15 on 921013-16.No Violations Noted. Major Areas Inspected:Emergency Facilities,Equipment & Implementing Procedures & Coordination of Emergency Planning W/Offsite Support Agencies ML20062H4231990-11-19019 November 1990 Insp Rept 70-1113/90-11 on 900924-28.No Violations or Deviations Noted.Major Areas Inspected:Nuclear Criticality Safety,Operations Review & Followup on 10CFR21 Reportable Items ML20059N3391990-09-28028 September 1990 Insp Rept 70-1113/90-08 on 900827-31.No Violations or Deviations Noted.Major Areas Inspected:Radwaste Mgt, Radioactive Effluent Sampling,Monitoring & Analysis & Radiological Environ Monitoring ML20246C0641989-08-0909 August 1989 Partially Withheld Insp Rept 70-1113/89-10 on 890718-19 (Ref 10CFR2.790).Violations Re Controlled Access Area Noted But Not Cited.Major Areas Inspected:Physical Protection of Low Enriched Nuclear Matl ML20245E6791989-08-0303 August 1989 Partially Withheld Insp Rept 70-1113/89-09 on 890626-30 (Ref 10CFR2.790 & 73.21).No Violations or Deviations Noted. Major Areas Inspected:Mc&A Sys Mgt & Assessment,Internal Controls,Measurement Sys & Measurement Controls ML20248C1411989-07-27027 July 1989 Insp Rept 70-1113/89-05 on 890522-26 & 0612-15.Violations Noted.Major Areas Inspected:Licensee Radiation Protection Programs for Assuring Personnel Exposures Maintained ALARA, & Review of Previously Identified Inspector Followup Items ML20246E7181989-06-29029 June 1989 Insp Rept 70-1113/89-06 on 890605-09.No Violations & Deviations Noted.Major Areas Inspected:Emergency Preparedness,Radiological Contingency & Emergency Plan.Two Drill Weaknesses Identified ML20246C0611989-06-27027 June 1989 Insp Rept 70-1113/89-08 on 890530-0602.No Violations or Deviations Noted.Major Areas Inspected:Nuclear Criticality Safety,Operations Review,Maint & Surveillance Testing ML20244D8301989-05-25025 May 1989 Insp Rept 70-1113/89-04 on 890424-28.Non-cited Violation Identified.No Deviations Noted.Major Areas Inspected: Radwaste Mgt,Radioactive Effluent Sampling,Monitoring & Analysis & Radiological Environ Monitoring ML20246J7991989-05-0404 May 1989 Insp Rept 70-1113/89-03 on 890327-31.No Violations or Deviations Noted.Major Areas Inspected:Previously Identified Fire Protection/Prevention Program Findings from Oct 1986 Operational Safety Assessment Insp 1999-09-08 Category:NRC-GENERATED MONTHYEARML20216F1281999-09-0808 September 1999
[Table view]Insp Rept 70-1113/99-05 on 990809-13.No Violations Noted. Major Areas Inspected:Rountine Unannounced Insp Involved Observation of Work Activities,Review of Selected Records ML20211L3001999-08-31031 August 1999 Insp Rept 70-1113/99-04 on 990726-0805.No Violations Noted. Major Areas Inspected:Plant Operations,Mgt Organization & Controls,Maint/Surveillance & Emergency Preparedness ML20211F2551999-08-25025 August 1999 Insp Rept 70-1113/99-202 on 990802-06.No Violations Noted. Major Areas Inspected:Implementation of GE Fire Protection Program Commitments Re Safe Plant Operations ML20210V2051999-08-13013 August 1999 Insp Rept 70-1113/99-03 on 990712-16.No Violations Noted. Major Areas Inspected:Environ Monitoring Program ML20195D4131999-06-0404 June 1999 Partially Withheld Insp Rept 70-1113/99-201 Conducted on 990510-14.No Violations Noted.Details Withheld,Per 10CFR2.790 ML20203G4671999-02-0505 February 1999 Insp Rept 70-1113/99-01 on 990111-15.No Violations Noted. Major Areas Inspected:Observation of Work Activities,Review of Selected Records & Interviews with Personnel in Area of Radiation Protection ML20202J1001999-01-29029 January 1999 Insp Rept 70-1113/99-02 on 990104-08.No Violations Noted. Major Areas Inspected:Plant Operations,Environ Protection & Training ML20155A8561998-09-30030 September 1998 Insp Rept 70-1113/98-05 on 980908-10.No Violations Noted. Major Areas Inspected:Licensee Program for Security & Safeguards ML20154C3421998-09-11011 September 1998 Insp Rept 70-1113/98-03 on 980817-21.No Violations Noted. Major Areas Inspected:Evaluation of Licensee Conduct of Transportation Program for Radioactive Matls & Radioactive Waste Mgt Program ML20154C1651998-09-0404 September 1998 Insp Rept 70-1113/98-04 on 980810-14.No Violations Noted. Major Areas Inspected:Assessment of Licensee Emergency Preparedness Program & State of Readiness for Responding to Various Postulated Accidents ML20151S8091998-09-0303 September 1998 Partially Withheld Insp Rept 70-1113/98-204 on 980810-14. Details Withheld (Ref 10CFR2.790) ML20237B4241998-08-0707 August 1998 Insp Rept 70-1113/98-02 on 980713-17.No Violations Noted. Major Areas Inspected:Evaluation of Licensee Conduct of Plant Operations,Mgt Controls & Environ Protection Program ML20247H9921998-05-14014 May 1998 Insp Rept 70-1113/98-202 on 980420-24.Noncited Violation Noted.Major Areas Inspected:Implementation of GE Fire Protection Program ML20247H8581998-05-13013 May 1998 Insp Rept 70-1113/98-203 on 950504-08.Noncited Violations Noted.Major Areas Inspected:Review of Adequacy of Licensee Criticality Safety Program ML20216D3001998-04-0808 April 1998 Partially Withheld Insp Rept 70-1113/98-201 on 980309-13. No Violations Identified.Details Withheld Per 10CFR2.790 ML20217G1081998-03-26026 March 1998 Insp Rept 70-1113/98-01 on 980223-27.Violations Noted. Major Areas Inspected:Evaluation of Licensee Conduct of Plant Operations & Training ML20199B4051998-01-0606 January 1998 Insp Rept 70-1113/97-08 on 971208-12.No Violations Noted. Major Areas Inspected:Licensee Conduct of Plant Operations & Maint ML20198H4351997-09-0404 September 1997 Partially Withheld Insp Rept 70-1113/97-203 on 970811-15, Per 10CFR2.790 ML20216B1821997-08-29029 August 1997 Insp Rept 70-1113/97-07 on 970714-18.No Violations Noted. Major Areas Inspected:Safety Operations,Radioactive Solid Waste Mgt,Transportation & Emergency Preparedness ML20141J7671997-08-11011 August 1997 Insp Rept 70-1113/97-06 on 970623-27.No Violations Noted. Major Areas Inspected:Status of Dry Conversion Facility, Including Completion of Const,Nuclear Criticality Safety, Chemical Safety & Radiation Protection ML20140E6571997-06-0606 June 1997 Insp Rept 70-1113/97-04 on 970326-28,0407-11 & 0429-0509. No Violations Noted.Major Areas Inspected:Status of New Dry Conversion Facility,Including Operations & Completion of Const ML20141K7021997-05-16016 May 1997 Insp Rept 70-1113/97-05 on 970414-18.No Violations Noted. Major Areas Inspected:Rp & FP Programs ML20138J8401997-04-18018 April 1997 Insp Rept 70-1113/97-03 on 970323-27.No Violations Noted. Major Areas Inspected:Environ Protection & Waste Mgt Programs & Status of New Dry Conversion Facility ML20137T5471997-04-0808 April 1997 Insp Rept 70-1113/97-02 on 970303-07 & 17-21.No Violations Noted.Major Areas Inspected:Operations,Training,Construction Completion & Training & Functional Testing of Sys ML20137P8141997-03-0707 March 1997 Insp Rept 70-1113/97-201 on 970303-07.Violation Noted.Rept Details Withheld ML20217D7331997-02-27027 February 1997 Insp Rept 70-1113/97-01 on 970127-31.No Violations Noted. Major Areas Inspected:Plant Operations,Management Organization & Controls,Maintenance/Surveillance,Training & Dcf Project ML20134G9851997-01-28028 January 1997 Special Insp Team Rept 70-1113/96-12 on 961204-08.Violations Noted.Major Areas Inspected:Circumstances Surrounding Tube Failure,Precursors to Event & Response to Event ML20134Q3121996-11-13013 November 1996 Insp Rept 70-1113/96-11 on 961014-18.No Violations Noted. Major Areas Inspected:Plant Operations,Mgt Organization & Control,Maint/Surveillance & Dcf Project ML20134J4071996-11-0606 November 1996 Insp Rept 70-1113/96-10 on 960930-1003.Violations Noted. Major Areas Inspected:Elements of Internal Dose Monitoring & Controls Program Including Activities in Urinalysis Bioassy & Associated Air Sampling Program ML20134C4891996-09-0909 September 1996 Insp Rept 70-1113/96-07 on 960805-09.No Violations Noted. Major Areas Inspected:Review of Listed Physics Program Elements,Independent Radiation Safety Audit,External & Internal Exposure Controls & Organizational Change ML20058P6741993-12-0808 December 1993 Insp Rept 70-1113/93-11 on 931115-19.Non-cited Violations Identified.Major Areas Inspected:Mgt Controls,Organization, Nuclear Criticality Safety,Facility Changes,Maintenance, Operations & NRC Bulletins & Notices ML20058P5011993-12-0303 December 1993 Insp Rept 70-1113/93-10 on 931025-29 & 1101-05.No Violations Noted.Major Areas Inspected:Evaluation of Fuel Processing in Selected Favorable Geometry Operations & Nuclear Criticality Safety Aspects of Modifications Made to Conversion Lines ML20058Q2071993-10-17017 October 1993 Insp Rept 70-1113/93-09 on 930913-17.No Violations Noted. Major Areas Inspected:Licensee Radiation Protection Program Including Program Organization & Staffing,Procedures & Program Changes & Training ML20057E7331993-09-30030 September 1993 Insp Rept 70-1113/93-08 on 930907-10.No Violations or Deviations Noted.Major Areas Inspected:Emergency Preparedness & Which Included Listed Program Elements ML20057C1271993-09-20020 September 1993 Insp Rept 70-1113/93-202 on 930816-20.No Violations Noted. Major Areas Inspected:Mc&A Sys Mgt & Assessment. Proprietary Insp Rept Details Withheld ML20057C2901993-09-15015 September 1993 Insp Rept 70-1113/93-07 on 930830-0903.No Violations or Deviations Noted.Major Areas Inspected:Nuclear Criticality Safety,Operations,Fire Protection,Facility Changes & NRC Bulletins & Notices ML20056E2851993-08-12012 August 1993 Insp Rept 70-1113/93-06 on 930726-30.No Violations Noted. Major Areas Inspected:Mgt Controls,Nuclear Criticality Safety,Maint & Fire Protection ML20056F3711993-08-10010 August 1993 Insp Rept 70-1113/93-05 on 930712-16.No Violations Noted. Major Areas Inspected:Radioactive Effluents,Environ Protection & Transportation of Radioactive Matl ML20128G4351993-02-0202 February 1993 Insp Rept 70-1113/93-01 on 930111-15.No Violations or Deviations Noted.Major Areas Inspected:Mgt Controls,Facility Changes,Facility Operations & follow-up of Previously Identified Items ML20128C9151992-11-23023 November 1992 Insp Rept 70-1113/92-17 on 921109-13.No Violations or Deviations Noted.Major Areas Inspected:Mgt Controls,Facility Operations,Facility Changes,Followup on Previously Identified Items & Current Issues ML20128C0081992-11-23023 November 1992 Insp Rept 70-1113/92-15 on 921013-16.No Violations Noted. Major Areas Inspected:Emergency Facilities,Equipment & Implementing Procedures & Coordination of Emergency Planning W/Offsite Support Agencies ML20062H4231990-11-19019 November 1990 Insp Rept 70-1113/90-11 on 900924-28.No Violations or Deviations Noted.Major Areas Inspected:Nuclear Criticality Safety,Operations Review & Followup on 10CFR21 Reportable Items ML20059N3391990-09-28028 September 1990 Insp Rept 70-1113/90-08 on 900827-31.No Violations or Deviations Noted.Major Areas Inspected:Radwaste Mgt, Radioactive Effluent Sampling,Monitoring & Analysis & Radiological Environ Monitoring ML20246C0641989-08-0909 August 1989 Partially Withheld Insp Rept 70-1113/89-10 on 890718-19 (Ref 10CFR2.790).Violations Re Controlled Access Area Noted But Not Cited.Major Areas Inspected:Physical Protection of Low Enriched Nuclear Matl ML20245E6791989-08-0303 August 1989 Partially Withheld Insp Rept 70-1113/89-09 on 890626-30 (Ref 10CFR2.790 & 73.21).No Violations or Deviations Noted. Major Areas Inspected:Mc&A Sys Mgt & Assessment,Internal Controls,Measurement Sys & Measurement Controls ML20248C1411989-07-27027 July 1989 Insp Rept 70-1113/89-05 on 890522-26 & 0612-15.Violations Noted.Major Areas Inspected:Licensee Radiation Protection Programs for Assuring Personnel Exposures Maintained ALARA, & Review of Previously Identified Inspector Followup Items ML20246E7181989-06-29029 June 1989 Insp Rept 70-1113/89-06 on 890605-09.No Violations & Deviations Noted.Major Areas Inspected:Emergency Preparedness,Radiological Contingency & Emergency Plan.Two Drill Weaknesses Identified ML20246C0611989-06-27027 June 1989 Insp Rept 70-1113/89-08 on 890530-0602.No Violations or Deviations Noted.Major Areas Inspected:Nuclear Criticality Safety,Operations Review,Maint & Surveillance Testing ML20244D8301989-05-25025 May 1989 Insp Rept 70-1113/89-04 on 890424-28.Non-cited Violation Identified.No Deviations Noted.Major Areas Inspected: Radwaste Mgt,Radioactive Effluent Sampling,Monitoring & Analysis & Radiological Environ Monitoring ML20246J7991989-05-0404 May 1989 Insp Rept 70-1113/89-03 on 890327-31.No Violations or Deviations Noted.Major Areas Inspected:Previously Identified Fire Protection/Prevention Program Findings from Oct 1986 Operational Safety Assessment Insp 1999-09-08 Category:TEXT-INSPECTION & AUDIT & I&E CIRCULARS MONTHYEARML20216F1281999-09-0808 September 1999
[Table view]Insp Rept 70-1113/99-05 on 990809-13.No Violations Noted. Major Areas Inspected:Rountine Unannounced Insp Involved Observation of Work Activities,Review of Selected Records ML20211L3001999-08-31031 August 1999 Insp Rept 70-1113/99-04 on 990726-0805.No Violations Noted. Major Areas Inspected:Plant Operations,Mgt Organization & Controls,Maint/Surveillance & Emergency Preparedness PNO-II-99-033, on 990830,Hurricane Dennis Was Located Approx 72 Miles Southeast of Bsep.No Significant Damage Has Been Sustained at Site.Ge Facility Suspended Fuel Fabrication Processes & No Significant Damage Was Sustained1999-08-30030 August 1999 PNO-II-99-033:on 990830,Hurricane Dennis Was Located Approx 72 Miles Southeast of Bsep.No Significant Damage Has Been Sustained at Site.Ge Facility Suspended Fuel Fabrication Processes & No Significant Damage Was Sustained ML20211F2551999-08-25025 August 1999 Insp Rept 70-1113/99-202 on 990802-06.No Violations Noted. Major Areas Inspected:Implementation of GE Fire Protection Program Commitments Re Safe Plant Operations ML20210V2051999-08-13013 August 1999 Insp Rept 70-1113/99-03 on 990712-16.No Violations Noted. Major Areas Inspected:Environ Monitoring Program ML20195D4131999-06-0404 June 1999 Partially Withheld Insp Rept 70-1113/99-201 Conducted on 990510-14.No Violations Noted.Details Withheld,Per 10CFR2.790 ML20203G4671999-02-0505 February 1999 Insp Rept 70-1113/99-01 on 990111-15.No Violations Noted. Major Areas Inspected:Observation of Work Activities,Review of Selected Records & Interviews with Personnel in Area of Radiation Protection ML20202J1001999-01-29029 January 1999 Insp Rept 70-1113/99-02 on 990104-08.No Violations Noted. Major Areas Inspected:Plant Operations,Environ Protection & Training ML20155A8561998-09-30030 September 1998 Insp Rept 70-1113/98-05 on 980908-10.No Violations Noted. Major Areas Inspected:Licensee Program for Security & Safeguards ML20154C3421998-09-11011 September 1998 Insp Rept 70-1113/98-03 on 980817-21.No Violations Noted. Major Areas Inspected:Evaluation of Licensee Conduct of Transportation Program for Radioactive Matls & Radioactive Waste Mgt Program ML20154C1651998-09-0404 September 1998 Insp Rept 70-1113/98-04 on 980810-14.No Violations Noted. Major Areas Inspected:Assessment of Licensee Emergency Preparedness Program & State of Readiness for Responding to Various Postulated Accidents ML20151S8091998-09-0303 September 1998 Partially Withheld Insp Rept 70-1113/98-204 on 980810-14. Details Withheld (Ref 10CFR2.790) ML20237B4241998-08-0707 August 1998 Insp Rept 70-1113/98-02 on 980713-17.No Violations Noted. Major Areas Inspected:Evaluation of Licensee Conduct of Plant Operations,Mgt Controls & Environ Protection Program ML20247H9921998-05-14014 May 1998 Insp Rept 70-1113/98-202 on 980420-24.Noncited Violation Noted.Major Areas Inspected:Implementation of GE Fire Protection Program ML20247H8581998-05-13013 May 1998 Insp Rept 70-1113/98-203 on 950504-08.Noncited Violations Noted.Major Areas Inspected:Review of Adequacy of Licensee Criticality Safety Program ML20216D3001998-04-0808 April 1998 Partially Withheld Insp Rept 70-1113/98-201 on 980309-13. No Violations Identified.Details Withheld Per 10CFR2.790 ML20217G1081998-03-26026 March 1998 Insp Rept 70-1113/98-01 on 980223-27.Violations Noted. Major Areas Inspected:Evaluation of Licensee Conduct of Plant Operations & Training ML20217G0971998-03-26026 March 1998 Notice of Violation from Insp on 980223-27.Violation Noted: on 980226,three Unscanned Solvent Drums Stored at Distances of Four to Ten Feet from Other Drum Arrays PNO-II-98-016, on 980316,licensee Declared Alert Due to Fire in Dumpster Located Outside Fuels Mfg Operations Bldg. Extinguished Fire,Inspected Roof & Posted Hourly Fire Watch. Licensee Will Investigate Root Causes & CAs to Be Taken1998-03-17017 March 1998 PNO-II-98-016:on 980316,licensee Declared Alert Due to Fire in Dumpster Located Outside Fuels Mfg Operations Bldg. Extinguished Fire,Inspected Roof & Posted Hourly Fire Watch. Licensee Will Investigate Root Causes & CAs to Be Taken ML20199B4051998-01-0606 January 1998 Insp Rept 70-1113/97-08 on 971208-12.No Violations Noted. Major Areas Inspected:Licensee Conduct of Plant Operations & Maint PNO-II-97-049, on 970904,stack Sample Above Licensee Action Was Noted.Sample Taken from H Fluoride Bldg Exhaust Stack.Environ Air Samples Collected at Site Boundary & Radioactivity Levels Determined to Be Background1997-09-0505 September 1997 PNO-II-97-049:on 970904,stack Sample Above Licensee Action Was Noted.Sample Taken from H Fluoride Bldg Exhaust Stack.Environ Air Samples Collected at Site Boundary & Radioactivity Levels Determined to Be Background ML20198H4351997-09-0404 September 1997 Partially Withheld Insp Rept 70-1113/97-203 on 970811-15, Per 10CFR2.790 ML20216B1821997-08-29029 August 1997 Insp Rept 70-1113/97-07 on 970714-18.No Violations Noted. Major Areas Inspected:Safety Operations,Radioactive Solid Waste Mgt,Transportation & Emergency Preparedness PNO-II-97-044, on 970808,thirty-seven Salaried Positions Eliminated,Fifteen Positions Resulted from Voluntary Separation & twenty-two Involuntary Eliminations.Areas Affected Were Design,Engineering & Production Scheduling1997-08-14014 August 1997 PNO-II-97-044:on 970808,thirty-seven Salaried Positions Eliminated,Fifteen Positions Resulted from Voluntary Separation & twenty-two Involuntary Eliminations.Areas Affected Were Design,Engineering & Production Scheduling ML20141J7671997-08-11011 August 1997 Insp Rept 70-1113/97-06 on 970623-27.No Violations Noted. Major Areas Inspected:Status of Dry Conversion Facility, Including Completion of Const,Nuclear Criticality Safety, Chemical Safety & Radiation Protection ML20140E6571997-06-0606 June 1997 Insp Rept 70-1113/97-04 on 970326-28,0407-11 & 0429-0509. No Violations Noted.Major Areas Inspected:Status of New Dry Conversion Facility,Including Operations & Completion of Const ML20141K7021997-05-16016 May 1997 Insp Rept 70-1113/97-05 on 970414-18.No Violations Noted. Major Areas Inspected:Rp & FP Programs ML20138J8401997-04-18018 April 1997 Insp Rept 70-1113/97-03 on 970323-27.No Violations Noted. Major Areas Inspected:Environ Protection & Waste Mgt Programs & Status of New Dry Conversion Facility ML20137T5471997-04-0808 April 1997 Insp Rept 70-1113/97-02 on 970303-07 & 17-21.No Violations Noted.Major Areas Inspected:Operations,Training,Construction Completion & Training & Functional Testing of Sys ML20137P8141997-03-0707 March 1997 Insp Rept 70-1113/97-201 on 970303-07.Violation Noted.Rept Details Withheld ML20217D7331997-02-27027 February 1997 Insp Rept 70-1113/97-01 on 970127-31.No Violations Noted. Major Areas Inspected:Plant Operations,Management Organization & Controls,Maintenance/Surveillance,Training & Dcf Project ML20134G9561997-01-28028 January 1997 Notice of Violation from Insp on 961204-08.Violation Noted: on 961130,engineered Control Associated W/Line 3 Calciner Tube Failure Did Not Detect Undesired Situation & Was Not Capable of Performing Criticality Safety Purpose Specified ML20134G9851997-01-28028 January 1997 Special Insp Team Rept 70-1113/96-12 on 961204-08.Violations Noted.Major Areas Inspected:Circumstances Surrounding Tube Failure,Precursors to Event & Response to Event ML20134Q3121996-11-13013 November 1996 Insp Rept 70-1113/96-11 on 961014-18.No Violations Noted. Major Areas Inspected:Plant Operations,Mgt Organization & Control,Maint/Surveillance & Dcf Project ML20134J4071996-11-0606 November 1996 Insp Rept 70-1113/96-10 on 960930-1003.Violations Noted. Major Areas Inspected:Elements of Internal Dose Monitoring & Controls Program Including Activities in Urinalysis Bioassy & Associated Air Sampling Program ML20134J3971996-11-0606 November 1996 Notice of Violation from Insp on 960930-1003.Violation Noted:Cm&S Analytical Method 1.2.21.10 Was Not Followed in That Data Derived from Urinalysis Tests Performed on 941019 Was Not Recorded ML20134C4891996-09-0909 September 1996 Insp Rept 70-1113/96-07 on 960805-09.No Violations Noted. Major Areas Inspected:Review of Listed Physics Program Elements,Independent Radiation Safety Audit,External & Internal Exposure Controls & Organizational Change ML20058P6741993-12-0808 December 1993 Insp Rept 70-1113/93-11 on 931115-19.Non-cited Violations Identified.Major Areas Inspected:Mgt Controls,Organization, Nuclear Criticality Safety,Facility Changes,Maintenance, Operations & NRC Bulletins & Notices ML20058P5011993-12-0303 December 1993 Insp Rept 70-1113/93-10 on 931025-29 & 1101-05.No Violations Noted.Major Areas Inspected:Evaluation of Fuel Processing in Selected Favorable Geometry Operations & Nuclear Criticality Safety Aspects of Modifications Made to Conversion Lines ML20058Q2071993-10-17017 October 1993 Insp Rept 70-1113/93-09 on 930913-17.No Violations Noted. Major Areas Inspected:Licensee Radiation Protection Program Including Program Organization & Staffing,Procedures & Program Changes & Training ML20057E7331993-09-30030 September 1993 Insp Rept 70-1113/93-08 on 930907-10.No Violations or Deviations Noted.Major Areas Inspected:Emergency Preparedness & Which Included Listed Program Elements ML20057C1271993-09-20020 September 1993 Insp Rept 70-1113/93-202 on 930816-20.No Violations Noted. Major Areas Inspected:Mc&A Sys Mgt & Assessment. Proprietary Insp Rept Details Withheld ML20057C2901993-09-15015 September 1993 Insp Rept 70-1113/93-07 on 930830-0903.No Violations or Deviations Noted.Major Areas Inspected:Nuclear Criticality Safety,Operations,Fire Protection,Facility Changes & NRC Bulletins & Notices ML20056E2851993-08-12012 August 1993 Insp Rept 70-1113/93-06 on 930726-30.No Violations Noted. Major Areas Inspected:Mgt Controls,Nuclear Criticality Safety,Maint & Fire Protection ML20056F3711993-08-10010 August 1993 Insp Rept 70-1113/93-05 on 930712-16.No Violations Noted. Major Areas Inspected:Radioactive Effluents,Environ Protection & Transportation of Radioactive Matl ML20128G4351993-02-0202 February 1993 Insp Rept 70-1113/93-01 on 930111-15.No Violations or Deviations Noted.Major Areas Inspected:Mgt Controls,Facility Changes,Facility Operations & follow-up of Previously Identified Items ML20128C9151992-11-23023 November 1992 Insp Rept 70-1113/92-17 on 921109-13.No Violations or Deviations Noted.Major Areas Inspected:Mgt Controls,Facility Operations,Facility Changes,Followup on Previously Identified Items & Current Issues ML20128C0081992-11-23023 November 1992 Insp Rept 70-1113/92-15 on 921013-16.No Violations Noted. Major Areas Inspected:Emergency Facilities,Equipment & Implementing Procedures & Coordination of Emergency Planning W/Offsite Support Agencies PNO-II-91-044, on 910709,licensee Inadvertently Transferred Approx 400 Gallons of Liquid Containing Small Amounts of U from Favorable Geometry Tank (T-417) to Unfavorable Tank (V-103).State of Nc Notified1991-07-10010 July 1991 PNO-II-91-044:on 910709,licensee Inadvertently Transferred Approx 400 Gallons of Liquid Containing Small Amounts of U from Favorable Geometry Tank (T-417) to Unfavorable Tank (V-103).State of Nc Notified PNO-II-91-043, on 910707,NRC Authorized GE Co to Resume Normal Operation of Fluoride & Nitrate Waste Sys,Which Had Been Shut Down Subsequent to 910528 Event at Site1991-07-0808 July 1991 PNO-II-91-043:on 910707,NRC Authorized GE Co to Resume Normal Operation of Fluoride & Nitrate Waste Sys,Which Had Been Shut Down Subsequent to 910528 Event at Site 1999-09-08 |
Text
-
p MATERfAt 1. . *a'AITTED HER.'
- CoNTAINS 2.h3 ANFCAMATN.,
e y 8d
.l* ' - UNITED STATES I
g g NUCLEAR REGULATORY COMMISSION o,
- REGION 11
[ 101 MARIETTA ST., N.W.
- e,,,, ATLANTA. GEORGIA 30323 FEB 2 71965 Report No.
- 70-1113/85-03 Licensee: General Electric Company Wilmington, NC 28401 Docket No.: 70-1113 License No.: SNM-1097 Facility Name: General Electric Company Inspection Conducted: February 5 - 8, 1985 Inspector: M' L E. L. Claf, Safeguar s Engirrear 1/2F/IS Date Signed Approved by: D C O_0 m'u E. J. McA? pine, Chief \ Material Control and 2/15/85 Date Signed Accountability Section, Nuclear Materials Safety and Safeguards Branch, Division of Radiation Safety and Safeguards
SUMMARY
Scope: This routine, unannounced inspection entailed 29 inspector-hours (27 hours3.125e-4 days <br />0.0075 hours <br />4.464286e-5 weeks <br />1.02735e-5 months <br /> at the site during normal duty hours, and 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> inspector-hours on backshift at the site) in the areas of measurement systems (85207), facility organization and management control (85203), inspector followup items (92701),
and independent inspection effort (92713).
Results: No violations or deviations were identified.