Northern States Power Company 414 N6cohet Mall Minneapobs Minnesota 55401 1elephone t012) 330 $500 February 10, 1993 10 CFR Part 50 Section 50.55a(g)

U S Nuclear Regulatory Commission Attn: Document Control Desk Vashington, DC 20555 PRAIRIE ISTAND NUCLEAR GENERATING PiANT Docket Nos. 50 282 License Nos. DPR 42 50 306 DPR 60 Vithdrawal of Letter Dated January 30, 1992 Addition..of Boric beid Tank to Relief Reauest No. 45

Reference:

Letter from Thomas M Parker, Northern States Power Company, to U S Nuclear Regulatory Commission dated January 30, 1992, titled

" Revised Relief Request No. 45 Second Ten Year Inservice Interval" In the referenced letter, we requested the addition of the boric acid tanks to the Prairie Island Inservice Inspection Prograin Relief Request No. 45.

Relief Request No. 45 was submitted 6 th the original Prairie Island Inservice Inspection and Testing Program Second Ten Year Interval on December 22,1983.

The NRC approved the Second Ten Year Inservice Inspection and Testing Program (including Relief Request No. 45) on December 28, 1984. Through further review of Section XI of the American Society of Mechanical Engineers Boiler and Pressure Vessel Code, we have determined that relief is unnecessary.

We, therefore, withdraw our letter of January 30, 1992.

We apologize for any inconvenience this inay have caused.

This letter contains no new NRC commitments.

Please contact Jack Leveille (612 388 1121, Ext, 4662) if you have any questions related to this letter.

))kh 4 4

Thomas M Parker Director Nuclear Licensing c: Regional Administrator Region III, NRC Senior Resident Inspector, NRC NRR Project Manager, NRC J E Silberg g

(I

.0 k l U

9302190274 930210 PDR ADOCK'00000202 PDR p

....