ML20128L444

From kanterella
Jump to navigation Jump to search
Provides Followup Info to Previous Telcon Re Excessive Removable Radioactive Surface Contamination on Packages Received in Shipments at Richfield,Wa Facility
ML20128L444
Person / Time
Site: Framatome ANP Richland
Issue date: 10/01/1996
From: Maas L
SIEMENS POWER CORP. (FORMERLY SIEMENS NUCLEAR POWER
To: Callan L
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
References
LJM:96:074, LJM:96:74, NUDOCS 9610150063
Download: ML20128L444 (2)


Text

D VD s

1 SIEMENS 00:f ?,

w October 1,1996 0

LJM:96:074

- U.S. Nuclear Regulatory Commission, Region IV Attn: L. J. Callan, Regional Administrator 611 Ryan Plaza Drive, Suite 400 Arlington, TX 76011

Dear Mr. Callan:

Subject:

Report of Excessive Removable Radioactive Surface Contamination on Package Received in Shipnient The following information is provided as followup to our eariier phone notification and to meet the reporting reciuirements of 10 CFR 20.1906(d)(1) pertaining to excessive removable radioactive surface contamination on packages received in shipment at our Richland, WA

~

lear fuel fabrication facility.

nuc Shioment Thirty eight (38) Model 30-B UF cylinders. These cylinders contained heels (net wt. less than 25 lbs. each) and sent to Siemens Power Corporation (SPC) for cylinder washing. Radionuclides: 8,908 grams U-235 (U234, U235, U236, U238 less than 5 wt% enriched) total shipment.

2 Items Imolicated Two (2) cylinders showing localized (approximately 300 cm per cylinder) removable radioactive surface contamination in excess of 10 CFR 71.87 (i)(2) limits.

Shioper Westinghouse Electric Corp.

Commercial Nuclear Fuel Division 5801 Bluff Road Columbia, S.C. 29209 RSB Lo0 stics, Inc.

i Carrier 4193 Crescent Dr.,

Suite E St. Louis, MI 63129 Date/ Time Received October 1,1996/0730 Date/ Time of Discoverv October 1,1996/ approx.1000 I

210019 Siemens Power Corporation Nuclear Division 2101 Horn Rapids Road Teh (509) 375-8100 Engineering & Manufacturing P.o. Box 130 Fax:

(509) 375-8402 Richimnri WA 49352-0130 O$

)((g

1 o-L. J. Callan

- LJM:96:074 October 1,1996 Page 2 Radioactive Surface Contamination Levels 2

2 Two cylinders averaged approximately 25,000 dpm/100 cm over approximately 300 cm area 2

on each cylinder (compared to 22,000 dpm/cm limit in 10 CFR 71.87(i)(2)). Remaining 36

. cylinders below reporting limits.

Action Taken Both cylinders decontaminated at receiving pad.

  • Truck surveyed as free of contamination and released.

Notified NRC Region IV office, shipper, and carrier regarding incident and current status.

Current Status No worker exposure or environmental release involved. No impact to plant operation.

If you have any questions, feel free to contact me at (509)375-8537.

9 Very truly yours, I

(

} = L. J. Maas, Man er

- Regulatory Com 'ance

/pg

-.