Preservice Insp Program Plan for Snubbers
ML20128L140
Person / Time
Site: Braidwood 
Issue date: 06/05/1985
From:
COMMONWEALTH EDISON CO.
To:
Shared Package
ML20128L139 List:
References
0290A, 290A, PROC-850605, NUDOCS 8507240312
Download: ML20128L140 (34)


Text

4

~

BRAIDWOOD STATION PRESERVICE INSPECTION,"

(PSI)

Program Plan for Snubbers June 5, 1985 8507240312$h456 ADOCK ppg PDR G

p p ' '~c,.~.,s.,.,,,..

N AYY Y

($ h. ] j d)l*

0641m(070185)

l l/

0290A

a

_l l

Table of Contents 1.0 Preservice Inspection Program for Snubbers 1.1 Program Description 1.2 Relief Requests 1.3 Tables for Preservice Snubber Testing Program 1.3.1 Braidwood 1 1.3.2 Braidwood 2 (later) 0641m(070185) 0290A

o l.1 Snubber Preservice Inspection Program The Snubber Preservice Inspection (PSI) Program is implemented in accordance with the requirements of Section XI of the ASME Boiler and Pressure Vessel Code, 1977 edition, through the summer of 1978 addenda.

The augmented preservice inspections, reflected in Commonwealth Edison's response to FSAR question 110.63, are also addressed in this preservice inspection program. That response takes guidance from EXAMINATION AND PERFORMANCE TESTING OF NUCLEAR PONER PLANT DYNAMIC RESTRAINTS (SNUBBERS)

O&M-4.

The following items are verified during snubber installation:

1) Installation is as identified on the design drawings for component supports.

If installation cannot be made per these drawings, component support installation guidelines and tolerances will be

used, n
2) Snubbers are not seized, frozen or jammed.

A documented visual examination will be performed on all safety related snubbers within 6 months prior to snubber preoperational or startup testing. This visual examination will verify the following:

3) No visible indications of damage or potential degraded operability due to the storage, handling, or installation of the snubbers.
4) No visible interference with the snubber from other components or structures.
5) Snubber attachments are in place and appear secure.
6) Hydraulic Snubber leak rates are less than or equal to design.

To satisfy items 1 through 6, credit will be taken for field examinations performed under the jur.isdiction of Commonwealth Edison Construction Department, as allowed by ASME Section XI.

All such inspections will be performed by ANSI certified inspectors.

If the testing schedule slips such that the visual examination (items 3 through 6) falls outside the six month time interval, the examination will be repeated by ANSI or VT certified inspectors.

If during the initial examination or subsequent examinations, snubber assemblies fail to meet the aforementioned criteria, they will be repaired or replaced, and the affected portions of the assembly will be reexamined.

Per response to FSAR Question 110.37, snubber movement will be recorded and clearances observed during Hot Functional Testing.

Since component support design is in a state of flux, new snubber locations may be added or changed in the plant design. This small percentage of snubbers will be examined as newly installed snubbers.

Testing of these snubbers, and other retesting, will be performed during startup as identified by engineering.

1 0641m(070185) 0290A

v--

.fe;;,

. a '.

.~

1.2 Relief Requests Relief Requests shall be necessary for the Snubber Inservice Program Plan and will;be identified during the performance of.the Preservice Inspections.

Relief requests will be included where specific requirements of Section XI are determined to be impracticable. c All relief requests will include the following information:

1.

An identification of the component (s)'for which relief is requested.

2.

The number of items associated with the requested relief.

3.

An identification of the specific ASME code. requirement that has been determined to be1 impractical.

~4.

The information to support the determination that the requirement is impractical;-

i.e., statement'and explanation of the basis for requesting relief.

5. LAn identification of the. alternate examinations that are proposed:

a.

In lieu of the requirements of Section XI; or b.

To supplement examinations performed partially in compliance with the-requirements of Section XI.

6.

A description and justification of any changes expected in the overall level of plant safety-by performing the proposed alternative examination in lieu of the examination required by Section XI.

If it is not possible to perform alternative examinations, a discussion 'of 1

the impact od the overall level of. plant quality and safety will be presented.

7.

A statement when the request for relief would apply during the inspection period or interval (i.e. whether the request is to defer an examination).

8.

A statement explaining when the proposed alternate examinations will be inplemented and performed.

9.

A statement identifying the time period for which the requested relief is needed.

NOTE i

F Technical justification or data will be submitted to support the relief reques,t. Statements regarding changes in, quality levels will be technically supported.

If the relief is requested for.

[

-inaccessibility, a. detailed description or drawing which depicts the inaccessibility will accompany the request. Relief requests will be

[

presented following the snubber tables.

2 0641m(070185) 0290A i.

09 SECTION 1.3.1 TABLES FOR PRESERVICE SNUBBER TESTING PROGRAM BRAIDWOOD UNIT 1 0641m(070185) 0290A

F..

v g

The following information is included in the Program Tables:

Snubber Assembly No.

The snubber number identifies a specific snubber by its unique number.

Its number references the unit and the system which contains the pipe or component that the snubber supports.

Elevation and Location Snubber locations are designated by a rectangular coordinate system using column numbers for all areas of the plant. The column numbers listed for the snubbers in containment are based on a rectangular coordinate system that is unique to the containment building.

Design Load (Normal and Upset)

The design load listed for the snubber is the sum of the normal and upset loading for that snubber in units of kips. This entry does not reflect the maximum capacity of the snubber sinc.e the snubbers were chosen to have greater maximum design capacities than their expected loading.

Accessible or Inaccessible This column refers to the feasibility of reaching a snubber for visual inspections during plant operation or to take data on its position setting. This information will be accumulated as the PSI progresses.

High Radiation Zone This entry reflects ALARA concerns in that it defines snubbers whose inspection or testing will require excessive exposure of personnel.

This will not present any problems during the PSI, since it will be executed prior to loading fuel. Snubbers in possible high radiation areas will be identified prine to the first inservice examination.

Especially Difficult To Remove This entry will identify snubbers which have limited access, making their removal difficult, though they may be accessible for visual examination. This information will be collected during execution of the PSI.

The tables are organized first according to system and then according to mechanical or hydraulic. Only the steam generators employ hydraulic snubbers.

NOTE: The snubbers listed on the following tables represent the most up-to-date information available to the station through design drawings, as of the date on the table. Since the component support designs are in a state of flux, these tables will be updated at least once prior to Hot Functionals and again prior to start-up.

L 1

0641m(070185) 0290A

~

Revision 1 F

PRESERVICE TESTING PROGRAM

~

SAFETY RELATED SNUBBERS BRAIDWOOD NUCLEAR POWER STATION Commonwealth Edison SYSTEM AF MECHANICAL SNUBBERS REVISION 1 DATE 6-1-85 PAGE 2 OF. 29 Design Accessible High Especially Snubber Elevation Load (Normal Or Radiation Difficult Assembly And

& Upset)

Inaccessible Zone To Remove No.

Location (Kips)

(A or I)

(Yes or No)

(Yes or No) 1AF05066S 401 T UN 1AF06004S 377 T UN lAF06042S 401 T UN b

2 0641m(070185) 0290A

Revision 1 PRESERVICE TESTING PROGRAM SAFETY RELATED SNUBBERS BRAIDWOOD NUCLEAR POWER STATION Commonwealth Edison SYSTEM CC MECHANICAL SNUBBERS REVISION O DATE 4-1-84 PAGE 3 OF 29 Design Accessible High Especially Snubber Elevation Load (Normal Or Radiation Difficult Assembly And

& Upset)

Inaccessible Zone To Remove No.

Location (Kips)

(A or I)

(Yes or No)

(Yes or No) 1CC19017S 426 RA R7 1CC19018S 418 RB R7 ICC20012S 401 RD R2 ICC20024S 418 RD R2 1CC20025S 401 RD R2 1CC22004S 426 RC R1 1CC24013S 418 RM R7 1CC24028S 426 RL R7 1CC24029S 426 RM R7 1CC24030S 426 RM R4

~

's 3

0641m(070185) 0290A

+.,,..

=.

=,.

I' Revision 1 PRESERVICE TESTING PROGRAM SAFETY RELATED SNUBBERS' BRAIDWOOD NUCLEAR POWER STATION Commonwealth n

Edison-

.-SYSTEM CS MECHANICAL SNUBBERS REVISION 1 DATE 6-1-85 PAGE 4 -OF 29 Design Accessible High Especially Snubber Elevation Load (Normal Or Radiation Difficult Assembly And

& Upset)

Inaccessible Zone To Remove No.

Location (Kips)

(A or I)

(Yes or No)

(Yes or No) i ICS03012S 401 U 13 1CS03018S 364 X 14 ICS03022S 383 Y 12 1CS03062S 383 Y 13 1CSO4002S 418 RE R1 1CSO4010S 418 RD R2 1CS05005S 451 RH R1 1CS08015S 346 X 13 l

(

l 4

2 0641m(070185)

' 0290A a

Revision 1 PRESERVICE TESTING PROGRAM SAFETY RELATED SNUBBERS BRAIDWOOD NUCLEAR POWER STATION Commonwealth Edison

+

' SYSTEM CV MECHANICAL SNUBBERS REVISION 1 DATE 6-1-85 PAGE 5 OF. 29 Design Accessible High Especially Snubber Elevation ~

Load (Normal Or Radiation Difficult Assembly And

& Upset)

Inaccessible Zone To Remove No.

Location (Kips)

(A or I)

(Yes or No)

(Yes or No)

ICV 01006S 383 Z 13 1CV01030S 383 U 13

~

1CV01040S 383 Z 13 1CV01083S 383 U 15' 1CV02002S 383 RH R8 1CV02003S 401 RH R8 1CV02004S' 426 RH R8-ICV 02005S 418 RH R8 1CV02007S' 426 RH R9 1CV02010S 383 RH R8 1CV02011S 426 RG R9 1CV03002S 383 RE R8 1CV03003S 383 RE R8 1CV03004S 401 RE R8 1CV03007S 401 RE R9 1CV03009S 426 RF R9

-1CV03013S 401 RE R8 1CV03015S 401 RF R9 1CV04005S 418 RG R9 1CV04013S 426 RK R6 1CV04015S' 426 RK R6 1CV04018S 418 RJ R4 1CV04025S 426 RK R2 1CV04030S 418 RK R2 1CV04033S 426 RG R9 1CV04035S 426 RJ R9 1CV04036S 426 RJ R9 1CV04038S 426 RK R6 1CV04039S 418 RK R5 1CV04040S 426 RK R5 1CV04047S 426 RK R3 1CV06003S 401 RH R3 1CV06008S 401 RH R2 1CV060105 5

0641m(070185) 0290A

1 :-

~

Revision 1

~

PRESERVICE TESTING PROGRAM SAFETY RELATED SNUBBERS BRAIDWOOD NUCLEAR POWER STATION Commonwealth Edison SYSTEM CV MECHANICAL SNUBBERS REVISION 1 DATE 6-1-85 PAGE 6 OF 29 Design Accessible High Especially Snubber Elevation

. Load (Normal Or Radiation Difficult Assembly And

.& Upset)

Inaccessible Zone To Remove No.

Location (Kips)

'(A or I)

(Yes or No)

(Yes or No)

ICV 06014S 401 RH R3

-lCV06016S 401 RH R3 ICV 06017S 401 RH R2

-ICV 06019S 401 RH R4 1CV06022S 401' RH R2 1CV0700lS 418 RK R3 1CV07008S 426. RJ R2 1CV07021S 426 RK R2

~1CV07024S 426 RJ R2 1CV07031S 426 RJ R1

-ICV 07032S 426 RJ R2 1CV07033S 401 RH R1 1CV07042S 426 RJ R2

-ICV 07049S 418 RJ R1 1CV07064S' 418 RJ R1 1CV07066S 418 RJ R2 1CV07067S'-

426 RJ R1 ICV 07068S ICV 08006S 383 Z 13 1CV08010S 383 Z 13' 1CV08013S 383 Z 13 ICV 08021S 383 V 13 1CV08027S 383 V 14 1CV09003S 401 RK R3

-lCV09005S 401 RJ R4' 1CV09006S 401 RJ R4 1CV09007S 401 RJ R4 1CV09018S 401 RH R2 l

t j

6 0641m(070185) 0290A

-4

La s

_ Revision 1 PRES?.RVICE TESTING PROGRAM i

SN ET'I RELATED SNUBBERS BRAIDWOOD NUCLEAR POWER STATION Commonwealth Edison SYSTEM CV MECHANICAL SNUBBERS REVISION 1 DATE 6-1-85 P,41E 7 OF'29 Design Accessible High Especially Snubber Elevation Load (Normal Or Radiation Difficult Assembly And

& Upset)

Inaccessible Zone To Remove No.

Location (Kips)

(A or I)

(Yes or No)

(Yes or No) 1CV09029S 383 RJ R3 1CV09030S 383 RJ R3 1CV09034S 426 RJ R4 1CV09038S 383 RJ R4 1CV09046S 426 RJ R3 1CV09049S 401 RH R2 1CV09050S 401 RH R2 1CV09051S 401 RH R2 1CV09053S 401 RT R3 1CV09054S 401 RJ R3 1CV09055S 418 RJ R4 1CV09056S 418 RJ R4 1CV09057S 426-RJ R4' 1CV09060S 383 RJ R3

' ICV 09061S 383 RJ R4 1CV09062S 383 RJ R4 1CV09063S 383 RJ R4 1CV09066S 383 RJ R4 1CV09068S 383 RJ R4 1CV09069S 383 RJ R4 ICV 11007S 383 RC R7 1CV11009S 383 RD R8 1CV11010S 383 RD R8 1CV110llS 383 RD R8 1CV11013S 383 RD R8 1CV11015S 383 RD R8 1CV11019S 383 RD R7 1CV11023S 383 RD R8 1CV11024S 383 RD R8 1CV11025S 383 RD R8 7

0641m(070185) 0290A

Revision 1 PRESERVICE TESTING PROGRAM SAFETY RELATED SNUBBERS' BRAIDWOOD NIK1 EAR POWER STATION Commonwealth Edison-'

-SYSTEM CV MECHANICAL SNUBBERS REVISION 1 DATE 6-1-85 PAGE 8 OF'29 Design Accessible High Especially Snubber Elevation Load (Normal Or' Radiation Difficult Assembly-And-

& Upset)

Inaccessible Zone To Remove No.

Location (Kips)

(A or I)

(Yes or No)

(Yes or No)

ICV 12002S 401 RD R8 1CV12003S 401 RD R8 1CV12005S 401 RD R8 1CV12006S 401 RD R8 1CV12007S 401 RD R8 1CV12017S 401 RD R9 1CV13051S 401 RJ R4 1CV130545 401 RJ R4 1CV1400lS 1CV14004S 1CV14039S 401, RD R4 1CV15002S 401 RJ R7 1CV15006S 401 RJ R6 1CV15013S 383 RJ R7 1CV15014S 383 RJ R7 1CV15015S 383 RJ R8 1CV15019S 401 RJ R8 1CV15020S 401 RJ R8 1CV15021S 401 RK R7 1CV15023S 401 RK R7 1CV15030S 401 RK R6 ICV 15032S 401 RK R6 1CV15039S 383 RJ R8 1CV15040S 383 RJ R8 1CV15046S 401 RJ R5 1CV15104S 401 RJ R5 1CV15109S 383 RJ R8 1CV15110S 383 RJ R8 1CV15111S 383 RJ R7 1CV16008S 401 RD R6 l

ICV 160095 401 RD R5 1

i l

8 0641m(070185) i f

0290A t

c

~

Revision 1 PRESERVICE TESTING. PROGRAM SAFETY RELATED SNUBBERS BRAIDWOOD NUCLEAR PO;TER STATION Commonwealth Edison SYSTEM CV MECHANICAL SNUBBERS REVISION 1 DATE 6-1-85 PAGE 9 OF '29 Desi.gn Accessible High Especially

' Snubber Elevation Load (Normal Or Radiation Difficult Assembly And

& Upset)

Inaccessible Zone To Remove No.

Location (Kips)

(A or I)

(Yes or No)

(Yes or No) 1CV18041S 401 W 15 1CV18077S 401 V 15 ICV 18097S 401 V 15 1CV180985 401 V 15 1CV22018S 426 RF R10 1CV24021S 401 RJ R8 1CV24023S 401 RJ R8

.lCV24024S 401 RJ R8 1CV24026S 401 RJ R8 1CV24027S 401 RJ R8 1CV24028S 1CV24039S 401 RJ R8 1CV25001S 383 RD R4 1CV25002S 383 RD R4 1CV25004S 9

0641m(070185) 8 0290A

Revision 1 PRESERVICE TESTING PROGRAM SAFETY RELATED SNUBBERS BRAIDWOOD NUCLEAR POWER STATION ra==nnwealth Edison SYSTEM CV MECHANICAL SNUBBERS REVISION 1 DATE 6-1-85 PAGE 10 OF 29 Design Accessible High Especially.

Snubber Elevation Load (Normal Or Radiation Difficult Assembly And

& Upset)

Inaccessible Zone To Remove No.

Location (Kips)

(A or I)

(Yes or No)

(Yes or No)

ICV 25009S 383 RD R4 1CV250115 383 RD R4 ICV 25014S 401 RD R4 ICV 25021S 401 RD R2 1CV250235 401 RE R2 1CV25024S 401 RE R2 1CV25026S 383 RE R2 1CV25027S 383 RF R2 1CV250345 1CV25051S 383 RD R4 1CV25052S 383 RF R2 1CV2700lS 401 RD R8 1CV27003S 401 RD R8 1CV27005S 401 RD R8 1CV28002S 401 RJ R9 1CV28003S 401 RJ R9 1CV28005S 401 RJ R9 1CV28041S 401 RH R9 1CV29005S 401 RJ R3 1CV29036S 401 RJ R3 1CV30002S 401-RD R3 ICV 30004S 401 RD R3 1CV31007S 401 RA R8 1CV31011S 401 RA R8 1CV31020S 401 RC Rl' 10

~0641m(070185) 0290A-s

=

Revision 1 PRESERVICE TESTING PROGRAM SAFETY RELATED SNUBBERS BRAIDWOOD NUCLEAR POWER STATION Commonwealth-

~ Edison SYSTEM CV MECHANICAL SNUBBERS REVISION 1 DATE 6-1-85 PAGE 11 OF.29 Design Accessible High Especially Snubber:

Elevation Load (Normal Or Radiation Difficult Assembly And

& Upset)

Inaccessible Zone To Remove No.

Location (Kips)

(A or I)

(Yes or No)

(Yes or No)

ICV 340085 401 RD R9 1CV36004S 401 RJ R8 ICV 36006S 401 RJ R8 1CV36007S 401 RJ R8 1CV40002S 401 RJ R2 1CV40005S 401 RJ R2 1CV40007S 401 RJ R3 1CV40008S 401 RJ R3 1CV40010S 401 RJ~R2 ICV 41025S 401 RD R1 1CV41026S 401 RD R1 1CV41031S 401 RD R3 1CV41034S 401 RD R3 1CV41035S 401 RD R3 1CV41036S 401 RD R4 1CV5000lS ICV 50005S 1CV50016S 1CV50023S ICV 51002S 401 Rif R8 1CV51005S 401 RJ R8 1CV51033S 401 Ri! R8 1CV52002S 401 RJ R4 1CV52006S 401 RJ R4 1CV52022S 401 Ri! R4' ICV 62007S 426 RL R3 1CV62020S 426 RK R3 1CV62031S 426 RL R7 1CV62037S 426 RM R7 1CV63029S 426 RL R6 1CV64037S 401 RE R4 1CV64038S 401 RE R4 1CV99022S 383 V 15 11 0641m(070185) 0290A s

h.

~

Revision 1 PRESERVICE TESTING PROGRAM SAFETY RELATED SNUBBERS BRAIDWOOD NUCLEAR POWER STATION Commonwealth Edison SYSTEM FW MECHANICAL SNUBBERS REVISION 1 DATE 6-1-85 PAGE 12 OF.29 Design Accessible High Especially Snubber

. Elevation Load (Normal Or Radiation Difficult Assembly And

& Upset)

Inaccessible Zone To Remove No.

' Location (Kips)

(A or I)

(Yes'or No)

(Yes or No) 1FWO2003S 401 RD R8 1FWO2012S 418 RE R7 1FWO2013S 401 RD R8 IFWO2016S 401 RD R8 1FWO3010S' 418 RK R7 1FWO3012S 418 RJ R7 lFWO3013S 426 RJ R6 1FWO3014S 418 RJ R7 1FWO3015S 401 RJ R7 1FWO3016S 401 RJ R8 1FWO3017S 401 RJ R8.

1FWO3019S 401 RJ R8 IFWO4005S 401 RK R6 1FWO40llS 401 RL R7 1FWO4013S 418 RK R6 1FWO4015S 451 RJ R4 1FWO4017S 401 LS 1FWO50llS 401 RB R7 1FWO5013S 401 RC R6 1FWO5014S 401 RC R6 1FWO5016S 418 RD R5 IFWO5017S 426 RD R5 1FWO5019S 426 RE RS 1FWO5020S 418 RC R6 1FWO5021S 401 RC R6-1FWO5022S 401 RC R6 1FWO6002S 451 RD A7 1FWO6003S 451 RD R7 IFWO6004S 426 RD R7 1FWO6005S 426 RD R7 1FWO6006S 426 RE R7 1FWO6008S 426 RD R7 1FWO6013S 426 RC R9 l

12 0641m(070185) 0290A

-s

Revision 1 PRESERVICE TESTING PROGRAM SAFETY RELATED SNUBBERS BRAIDWOOD NUCLEAR POWER STATION Commonwealth Edison SYSTEM EW MECHANICAL SNUBBERS REVISION 1 DATE 6-1-85 PAGE 13 OF'29 Design Accessible High Especially Snubber Elevation Load (Normal Or Radiation Difficult Assembly.

And

& Upset)

Inaccessible Zone To Remove No.

Location (Kips)

(A or I)

(Yes or No)

(Yes or No)

IFWO6014S 401 RC R8 1FWO6017S 401 RB R9 1FWO7002S 451 RJ R6 1FWO7003S 451 RJ R6 1FWO7004S 451 RJ R6 1FWO7005S 426 RJ R6 1FWO7006S 426 RJ R6 1FWO7012S 418 RK R8 1FWO7014S 401 RK R8 1FWO7017S 401 RL R9 1FWO7019S 426 RJ R8 1FWO8002S 451 RJ R5 I

1FWO8003S 451 RJ RS 1FWO8005S 451 RK RS 1FWO8006S 451 RK R5 1FWO8007S 426 RK R5 1FWO8008S 426 RK R5 1FWO8015S 426 RK R8 1FWO8016S 401 RK R8 1FWO8018S 401 RL R8 1FWO8019S 401 RL R8 1FWO9003S 451 RD RS 1FWO9004S 426 RD R5 1FWO9006S 426 RC R6 1FWO9007S 426 RC R6 1FWO9010S 126. RC R7 1FWO9013S 426 RB R7 IFWO9014S 4* 6 RB R7 i

1FWO9015S 40 RB R7 1FWO9017S 401 RB R8 1FWO90203 401 RB R8 IFWO9021S 451 RD R5 1FWO9022S 451 RD R5 l

1FWO9023S 401 RB R8 l

1FW1000lS 401 T UN l

1FW10004S 401 T UN IFW12025S 401 T UN l

1FW14002S 401 T UN 13 0641m(070185) t 0290A~

L

Revision 1 PRESERVICE TESTING PROGRAM SAFEIY RELATED SNUBBERS BRAIDWOOD NUCLEAR POWER STATION Commonwealth Edison SYSTEM MS MECHANICAL SNUBBERS REVISION 1 DATE 6-1-85 PAGE 14 OF 29 Design Accessible High Especially Snubber Elevation Load (Normal Or Radiatiorf Difficult Assembly-And

& Upset)

Inaccessible Zone To Remove No.

Location (Kips)

(A or I)

(Yes or No)

(Yes or No)

IMS01074S 418 T UN 1MS010795 416 T UN 1MS01083S 418 T UN 1MS01088S 416 T UN 1MS01092S 418 T UN 1MS01097S 418 T UN 1MS01101S 418 T.UN 1MS01106S 418 RR R20 1MS05003S 426 RC R9 1MS05004S 426 RC R9 1MS05005S 476 RC R9 1MS05007S 426 RC R9 1MS05008S 476 RC R8 1MS06003S 426 RK R8 1MS06004S 426 RK R8 1MS06005S 476 RK R8 1MS06007S 418 RK R8 1MS07003S 426 RK R8 1MS07004S 476 RK R8 1MS07006S 426 RK R8 1MS07007S 476 RK R8 1MS07008S 476 RK R8 1MS08004S 476 RC R8 1MS08007S 426 RC R8 14 0641m(070185) 0290A W

m.

r-Revision 1 PRESERVICE TESTING PROGRAM SAFETY RELATED SNUBBERS BRAIDWOOD NUCLEAR POWER STATION Commonwealth Edison SYSTEM RC HYDRAULIC SNUBBERS REVISION 1 DATE 6-1-85 PAGE 15 OF 29

~

Design Accessible High Especially Snubber Elevation Load (Normal Or Radiation Difficult Assembly

.And

& Upset)

Inaccessible Zone To Remove No.

Location (Kips)

(A or I)

(Yes or No)

(Yes or No) 1RC01BA-A 444 7C 1RC01BA-B 444 7C e-1RC01BB-A 444 7J 1RC01BB-B 444 7J IRC01BC-A 444 SJ 1RC01BC-B 444 SJ 1RC01BD-A 444 SC IWC01BD-B 444 SC 15 0641m(070185) 0290A

-7, ;.

g Revision 1 PRESERVICE TESTING PROGRAM SAFETY RELATED SNUBBERS BRAIDWOOD NUCLEAR POWER STATION

('a==nnwealth Edison SYSTEM 'RC MECHANICAL SNUBBERS REVISION 1 DATE 6-1-85 PAGE 16 OF.29 Design Accessible High Especially Snubber Elevation.

Load (Normal Or Radiation Difficult.

Assembly And

& Upset)

Inaccessible Zone To Remove No.

Location (Kips)

(A or I)

(Yes or No)

(Yes or No) 1RC01006S 401 RE R7 1RC01007S 401 RE R7 IRCO2006S 401 RJ R7 1RCO2007S 401 RJ R7 1RCO2008S 401 RH R7-1RC03005S 401 RH R4 1RC03006S 401 RH R4

'1RC03007S

'401 RJ R4 1RC03008S 401 RJ R4

-1RC04005S 1RC10001S 1RC10004S 401 RD R6 1RC10011S 401 RE R7 1RC10013S 401 RE R7 1RC10026S 1RC10030S 401 RE R7

.1RC100315 401 RE R7 1RC10032S 418 RE R7 1RC10034S 1RC10035S 418 RE R7 1RC10037S 1RC10039S 418 RE R8 1RC10040S 401 RE R8 1RC10041S 401 RE R8 1RC10043S 401 RD R8' 1RC10044S 401 RD R8 1RC10049S

-401 RE R8 1RC10051S 1RC10052S 1RC10054S 401 RE R7 1RC10055S' 401 RE R7 1RC10056S 401 RD R6 16 0641m(070185) 0290A W.

m

Revision 1 PRESERVICE TESTING PROGRAM SAFETY RELATED SNUBBERS BRAIDWOOD NUCLEAR POWER STATION Comonwealth Edison SYSTEM RC MECHANICAL SNUBBERS-REVISION 1 DATE 6-1-85 PAGE 17 OF 29 Design Accessible High Especially Snubber Elevation Load (Normal Or Radiation Difficult Assembly And

& Upset)

Inaccessible Zone To Remove No.

Location (Kips)

(A or I)

(Yes or No)

(Yes or No) 1RC11061S 401 Ril R7 1RC11062S 401 Ril R7 1RC11096S 401 Rif R7 1RC11097S 401 RH R8 1RC11098S 401 RH RS 1RC11104S' 401 RJ R6 1RC11105S 418 RH R7 1RCll106S 401 RH R8 1RC11107S 401 RJ R6 1RC11108S 401 Rif R8 1RCl2039S 401 RH R4 1RC12041S 418 Ril R4 1RC12048S 401 RH R4 1RC12053S 401 RJ R4 1RC12055S 1RCl2060S 401 RJ R5 1RC12061S 401 RH R5 1RC12072S 418 RH R5 1RC12090S 401 RH RS 1RCl2091S 401 RII R5 1RC12092S 401 Rif R5 1RCl2095S 401 RJ R5 1RC12097S 401 RJ R5 1RC12099S 401 Ril RS 1RC12101S 401 Ril R4' 1RC12102S 401 Ril R4 1RC12103S 401 Rif R4 1RC12104S 401 Ril R4 1RC13026S 401 RE RS 1RC13038S 401 RE R4 1RC13039S 418 RE R4 1RC13040S 401 RE R5 1RC13041S 1RCl3048S 1RC13064S 401 RD R5 1RC13069S 401 RE R4 1RC13073S 401 RD R4 1RC13074S 17 0641m(070185) 0290A

o,

.'s.

Revision 1 PRESERVICE TESTING PROGRAM SAFETY RELATED SNUDBERS BRAIDWOOD NUCLEAR POWER STATION Commonwealth Edison-SYSTEM RC MECHANICAL SNUBBERS REVISION O DATE 4-1-84 PAGE 18 OF 29 Design Accessible High Especially Snubber Elevation Load (Normal Or Radiation Difficult Assembly And

& Upset)

Inaccessible Zone To Remove No.

Location (Kips)

(A or I)

(Yes or No)

(Yes or No) 1RCl3076S 1RC13083S 401 RE R4 IRC13084S 401 RE R4 1RC13090S 418 RE RS 1RC13091S 401 RD R4 1RC13092S 418 RE R5 1RC14003S 1RC14004S 1RC14005S 364 RG R6 1RC14006S 364 RG R6 1RC14009S 1RC14010S 1RC14011S 364 RG R6 1RC14012S 364 RG R6 1RC16114S 401 RE R7 1RC16115S 401 RE R7 1RC16119S 401 RE R7 1RC17052S 401 RH R7 1RC17058S 401 RH R7 1RC17069S 401 RH h7 1RC18034S 401 RH R4 1RC18037S 401 RH R5 1RC18045S 401 RH R4 1RC19042S 401 RE R4 1RC19049S 401 RE R$

1RC19054S 401 RE R5 1RC19060S 401 RE R4 l

l 18 0641m(070185) 0290A

,s

B Revision 1 i

l l.

PRESERVICE TESTING PROGRAM

(_

SAFETY RELATED SNUBBERS BRAIDWOOD NUCLEAR POWER STATION l

Commonwealth Edison SYSTEM RE MECHANICAL SNUBBERS REVISION 1 DATE 6-1-85 PAGE 19 OF 29 Design Accessible High Especially Snubber Elevation Load (Normal Or Radiation Difficult Assembly And

& Upset)

Inaccessible Zone To Remove No.

Location (Kips)

(A or I)

(Yes or No)

(Yes or No)

- 1RE01007S 418 RB R4 1RE01014S 418 RF R1 I

i.

l I

l l

l 1

i l

l 19 0641m(070185) 0290A c

4 k

Revision 1 PRESERVICE TESTING PROGRAM SAFETY RELATED SNUBBERS BRAIDWOOD NUCLEAR POWER STATION Commonwealth Edison SYSTEM RH-MECHANICAL SNUBBERS REVISION 1 DATE 6-1-85' PAGE 20 OF'29 Design Accessible High Especially Snubber Elevation Load (Normal Or Radiation Difficult Assembly And

& Upset)

Inaccessible Zone To Remove No.

Location (Kips)

(A or I)

(Yes or No)

(Yes or No)

'1RH02002S 1RH02003S 401 RG R4

["

1RH02007S 383 RH R3 1RH02008S 381 RH R4 1RIIO2009S 383 RG R3 1RiiO2012S 401 RH R2 1RH02013S 401 Rif R2 1RH02018S 401 RG R4 1RH02019S 1RH02023S 1RH02027S 1RH02047S 1RH02049S 1RH02052S 401 RE R3 1RH02054S 383 RE R4 1RH02058S 401 RE RI 1RH02059S 383 RE R2 1RH02061S 401 RH R4 1RH02066S 1RIIO2067S 383 RH R1

'1RIIO2068S 383 RF R3 1RH02069S l

1RIIO20785 401 RF R4 1RH02079S 401 RE R5, 1RH02080S 401 R3 R1 1RiiO2081S 401 RH R1 I

1RH02082S 1RIIO2083S 401 RE R4 1RH02101S 401 RH R5 1RH02114S 401 RE R5 1RH02205S 401 RE R6 1RH02206S 401 RE R1 ERH02207S 401 RE R6 1R11022085 401 RE R6

-1RIIO2210S 401 RE R6 1RH02212S 401. RE R5 l

1RIIO2215S 401 RH R5 l

1R1102217S 401 Ril R5 1R1104011S 1RH04012S 383 W15 20 0641m(070185) 0290A s

t

Revision 1 PRESERVICE TESTING PROGRAM SAFETY RELATED SNUBBERS BRAIDWOOD NUCLEAR POWER STATION Commonwealth Edison

-SYSTEM -RH MECHANICAL SNUBBERS REVISION 1 DATE 6-1-85 PAGE 21 OF 29 Design Accessible High Especially Snubber Elevation Load (Normal Or Radiation Difficult Assembly And

& Upset)

Inaccessible Zone To Remove No.

Location (Kips)

(A or I)

(Yes or No)

(Yes or No) 1RH05003S 364 X 13 1RH07003S 1RH07006S 364 U 13 1RH07011S 364 V 12 1RH07012S 1RH07013S 364 V 12 1RH07025S 364 V 13 1RH08015S 9

4 9

9 21 0641m(070185) 0290A L.

Revision 1 PRESERVICE TESTING PROGRAM SAFETY RELATED SNUBBEPS BRAIDWOOD NUCLEAR POWER STATION Commonwealth Edison SYSTEM RY MECHANICAL SNUBBERS REVISION 1 DATE 6-1-85 PAGE 22 OF.29 Design Accessible High Especially Snubber Elevation Load (Normal Or Radiation Difficult Assembly And

& Upset)

Inaccessible Zone To Remove No.

Location (Kips)

(A or I)

(Yes or No)

(Yes or No) 1RYO5003S 401 RC R6 1RYO5010S

'lRYO6012S 401 RE R3 1RYO6017S 401 RE R4 1RYO6022S 418 RE R3 1RYO6026S 426 RE R3 1RYO6027S 426 RE R3

-lRYO6029S 426 RD R3 1RYO6030S 426 RE R3 lRYO6031S 451 RE R3 1RYO6033S 451 RE R3 1RYO6034S 476 RE R3 1RYO6047S 418 RE R3 1RYO6057S 401 RE R4 1RYO6059S

'401 RE R3 1RYO6068S 401 RE R3 1RYO6080S 401 RE R3 1RYO6082S 426. RE R3 1RYO6091S 401 RE R4 1RYO6096S 401 RE R4 1RYO6110S 401 RE R4 1RYO6.ll8S 476 RE R3 22 0641m(070185) 0290A 4

~

7n 4-,. -.

p

Revision 1 PRESERVICE TESTING PROGRAM SAFETY RELATED SNUBBERS BRAIDWOOD NUCLEAR POWER STATION Commonwealth Edison SYSTEM RY MECHANICAL SNUBBERS REVISION 1 DATE 6-1-85 PAGE 23 OF.29 Design Accessible High Especially Snubber Elevation Load (Normal Or Radiation Difficult Assembly And

& Upset)

Inaccessible Zone To Remove No.

Location (Kips)

(A or I)

(Yes or No)

(Yes or No) 1RYO6121S 401 RE R4 1RYO6124S 418 RE R3 1RYO6126S 401 RE R3 1RYO6153S 401 RE R4 1RYO6154S 401 RE R4 1RYO6156S 401 RE R4 1RYO6157S 401 RE R3 1RYO900lS 476 RE R3 1RYO9005S 476 RD R3 1RYO9012S 476 RD R2 1RYO9060S 476 RE R3 1RYO9067S 476 RE R3 1RYO9077S 1RYO9078S 1RYO9100S 476 RD R3 1RYO9101S 1RY27003S 476 RD R2 1RY27005S 451 RE R2 1RY27007S 451 RE R2 1RY27009S 451 RD R2 1RY27010S 451 RC R2 1RY27012S 451 RD R2 1RY27013S 451 RD R2 1RY27015S 451 RD R2 1RY27017S 451 RD R2-1RY27018S 451 RD R2 1RY27019S 451 RD R2 1RY27024S 451 RE R2 1RY27025S 451 RE R2 1RY27026S 1RY27027S 451 RD R2 23 0641m(070185) 0290A 4

-.e

,-.. o Revision 1 PRESERVICE TESTING PROGRAM SAFETY RELATED SNUBBERS BRAIDWOOD NUCLEAR POWER STATION Commonwealth Edison SYSTEM SD MECHANICAL SNUBBERS REVISION 1 DATE 6-1-85 PAGE 24 OF.29 Design Accessible High Especially Snubber Elevation Load (Normal Or Radiation Difficult AOsembly And

& Upset)

Inaccessible Zone To Remove No.

Location (Kips)

(A or I)

(Yes or No)

(Yes or No) 1SD01002S 418 RD R6 ISD01003S 418 RD R6 ISD01009S 418 RC R8 ISD01021S 401 RD R9 ISD01033S 401 RB R7 ISD01034S 401 RB R7 ISD01035S 401 RB R7 ISD01038S 401 RC R9 ISD01041S ISD01042S 413 RD R8 ISD02005S 418 RD R8 ISD020llS 418 RC R6 1SD02020S 401' RC R9 ISD02022S 401 RC R9

-lSD02029S.

ISD02036S 401 RC R7 1SD03013S lSD03016S 401 RL R7 ISD03020S 418 RK R6

'lSD03025S 401 RK R8 1SD03027S 418 RK R8 ISD03029S 418 RK R8 ISD03031S 401 RK R8 ISD03034S 418 RK R7 ISD03037S 418 RK R6'

~

ISD03038S 418 RK R6 ISD04002S ISD04004S 418 RJ R6 ISD04025S 400 RK R6 24 0641m(070185) 0290A y-.nn e

g-.

-n

o,

~

Revision 1 FRESERVICE TESTING PROGRAM SAFETY RELATED SNUBBERS BRAIDWOOD NUCLEAR POWER STATION Comonwealth Edison SYSTEM SD MECHANICAL SNUBBERS REVISION 1 DATE 6-1-85 PAGE 25 OF 29 Design Accessible High Especially Snubber Elevation Load (Normal Or Radiation Difficult Assembly And

& Upset)

Inaccessible Zone To Remove No.

Location (Kips)

(A or I)

(Yes or No)

(Yes or No)

ISD05046S 403 4H 0.100 lSD06027S 418 RK R7 1SD06029S 418 RJ R5 ISD06030S 418 RJ R4 ISD06032S ISD06037S 418 RK R7 ISD06040S ISD06051S 401 RM R8 ISD11066S 418 RD R5 ISD12002S 418 RD R5 ISD12016S 401 RB R8 ISD12017S 401 RB R7 ISD12048S 418 RD R4 1SD21033S 400 T UN y

9 25 0641m(070185) 0290A 1

Revision 1 PRESERVICE TESTING PROGRAM SAFETY RELATED SNUBBERS BRAIDWOOD NUCLEAR POWER STATION Commonwealth Edison SYSTEM SI MECHANICAL SNUBBERS REVISION 1 DATE 6-1-85 PAGE 26 OF-29 Design Accessible High Especially Snubber Elevation Load (Normal Or Radiation Difficult Assembly And

& Upset)

Inaccessible Zone To Remove No.

Location (Kips)

(A or I)

(Yes or No)

(Yes or No)

ISIO1002S 401 RE R8 ISIO1003S 401 RE R8 ISIO1004S 401 RE R8 ISIO1006S 401 RE R9 ISIO1007S 401 RE R10 ISIO1009S ISIO1011S ISIO1018S 401 RE R8 ISIO1020S 401 RE R8 ISIO1021S 401 RE R10 ISIO10255 426 RE R10 ISIO1029S 401 RF R7 ISIO1030S 401 RF R7 ISIO1031S 418 RE R9 ISIO1032S 418 RD R9 ISIO1034S 401 RE R9 ISIO1035S 426 RD R9 ISIO2003S 418 RB R7 ISIO3003S 426 RD R1 ISIO3006S ISIO3007S 426 RE R1 ISIO3009S 418 RF R1 ISIO3016S ISIO3018S ISIO3020S

'lSiO3021S 401 RE R4 ISIO3023S ISIO3024S 401' RE R5 ISIO3025S 401 RE R4 ISIO3028S 418 RD R4 ISIO3029S 401 RD R4 ISIO3038S 418 RC R5 l

1SIO3042S 401 RF R1 ISIO3046S 401 RE R3 ISIO4003S 401 RH R8 ISIO4004S 401 RH R8 26 0641m(070185) 0290A

]

Revision 1 PRESERVICE TESTING PROGRAM SAFETY RELATED SNUBBERS BRAIDWOOD NUCLEAR POWER STATION Commonwealth' Edison SYSTEM SI MECHANICAL SNUBBERS REVISION 1 DATE 6-1-85 PAGE 27 OF 29 Design Accessible High Especially Snubber Elevation Load (Normal Or Radiation Difficult AXsembly And

& Upset)

Inaccessible Zone To Remove No.

Location (Kips)

(A or I)

(Yes or No)

(Yes or No)

ISIO4005S 401 RH R8 ISIO4007S 401 RH R9 w

lSIO4016S 401 RG R8 ISIO4017S 401 RG R8 ISIO4019S 401. RH R9 ISIO4020S 418 RH R9 ISIO4022S 426 RH R10 ISIO4024S 418 RH R9 ISIO4026S ISIO4030S 426 RH R10 ISIO5002S ISIO5003S 383 S 14 ISIO5013S 383 W 13 ISIO5036S 383 Y 12 ISIO6008S 383 Y 14 ISIO6013S 383 Y 14 ISIO6027S 364 Y 13 ISIO6028S 364 Y 13 ISIO6030S 364 Y 13 ISIO6034S 346 Y 14 ISIO6035S 364 Y 13 ISIO6038S ISIO6044S 383 Y 13 ISIO6061S ISIO6076S ISIO6086S 364 Y 13 ISIO6088S 383 V 13 ISIO6091S 364 V 13 ISIO6123S ISIO6202S 364 Y 13 ISIO9002S 426 RK R1 ISIO9004S 426 RK R1 ISIO9006S 418 RH R1 27 0641m(070185) 0290A

o..

.o Revision 1 PRESERVICE TESTING PROGRAM SAFETY RELATED SNUBBERS BRAIDWOOD NUCLEAR POWER STATION Commonwealth Edison SYSTEM SI MECHANICAL SNUBBERS REVISION 1 DATE 6-1-85 PAGE 28 OF 29 Design Accessible High Especially Snubber Elevation Load (Normal Or Radiation Difficult Assembly -

And

& Upset)

Inaccessible Zone To Remove No.

Location (Kips)

(A or I)

(Yes or No)

(Yes or No)

ISIO9009S 426 RH Rl-ISIO9013S 401 RG R3 ISIO9015S ISIO9020S ISIO9021S 401 RH R4 ISIO9024S 401 RH R2 ISIO9025S 418 RH R2 ISIO9037S 401 RH R2 ISIO9038S ISIO9039S 401 RE R4 ISIO9043S 426 RH R1 ISIl0031S, 401 RE R5 ISIl0036S 401 RE R2 ISIl5014S ISI16010S 418 RF R1 ISI16029S 383 RH R1 ISIl6037S ISIl6038S ISIl8003S 383 U 12 ISIl8008S 383 W 13 ISIl8026S 383 V 12 ISIl8030S 383 U 12 ISIl8049S 383 Y 13 ISIl9007S 418 RH R9 ISI19011S 401 RH R7' 1SI19012S 28 0641m(070185)

-0290A 1

o Revision 1 PRESERVICE TESTING PROGRAM SAFETY RELATED SNUBBERS BRAIDWOOD NUCLEAR POWER STATION Commonwealth Edison

~

SYSTEM SX MECHANICAL SNUBBERS REVISION 1 DATE 6-1-85 PAGE 29 OF 29 Design Accessible High Especially Snubber Elevation Load (Normal Or Radiation Difficult Assembly And

& Upset)

Inaccessible Zone To Remove No.

Location (Kips)

(A or I)

(Yes or No)

(Yes or No)

ISX07032S ISX09029S lSX09038S 401 RL R9 ISXO9045S ISXO90535 29

-0641m(070185) 0290A 4