Category:PRELIMINARY NOTIFICATION OF EVENT OR OCCURRENCE (PNO
MONTHYEARPNO-I-88-057A, identified Radioactive Contamination on Contractor Exiting Facility Protected Area.Contamination Also Identified in Individual Home & co-worker Car.Caused by Inadequate Monitoring Before Leaving Restricted Area1988-06-22022 June 1988 PNO-I-88-057A:identified Radioactive Contamination on Contractor Exiting Facility Protected Area.Contamination Also Identified in Individual Home & co-worker Car.Caused by Inadequate Monitoring Before Leaving Restricted Area ML20212R5131987-04-20020 April 1987 PNS-i-87-006:on 870420,bomb Threat Received by Monroe County Police Emergency Notification Dispatcher.Security Personnel Posted on Plant Access Roads to Verify Id Prior to Access to Plant.State & Local Police Patrolled Area PNO-I-86-058, on 860729,reactor Manually Tripped from 100% Power Due to Break in Drain Line from Main Steam Reheater 2A to Feedwater Heater 5A.Cause Under Investigation.Licensee Actions Under Review1986-07-29029 July 1986 PNO-I-86-058:on 860729,reactor Manually Tripped from 100% Power Due to Break in Drain Line from Main Steam Reheater 2A to Feedwater Heater 5A.Cause Under Investigation.Licensee Actions Under Review PNO-I-85-085A, on 851106,licensee Secured from Unusual Event Declared Due to Automatic Actuation of Cable Tunnel Deluge Sys.Caused by Faulty Printed Circuit Card.Ground on Nonvital Bus Damaged by Deluge Sys Corrected1985-11-0707 November 1985 PNO-I-85-085A:on 851106,licensee Secured from Unusual Event Declared Due to Automatic Actuation of Cable Tunnel Deluge Sys.Caused by Faulty Printed Circuit Card.Ground on Nonvital Bus Damaged by Deluge Sys Corrected PNO-I-85-085, on 851106,fire Protection Deluge Sys in Cable Tunnel Automatically Actuated.Smoke Smelled at Scene.Sys Isolated After 10 Minutes of Operation.Visual Insp of Cable Tunnel Revealed No Apparent Damage1985-11-0606 November 1985 PNO-I-85-085:on 851106,fire Protection Deluge Sys in Cable Tunnel Automatically Actuated.Smoke Smelled at Scene.Sys Isolated After 10 Minutes of Operation.Visual Insp of Cable Tunnel Revealed No Apparent Damage ML20128L0521985-07-18018 July 1985 PNS-I-85-010:on 850718,safeguards Contingency Plan Drill Will Be Held.Exercise Will Test Command/Control, Communications & Response Force Mobilization Developed by State of Ny Emergency Mgt Agency ML20236L5201979-10-24024 October 1979 PNS-I-79-005:on 791023,unidentified Male Called Rochester Gas & Electric Corp Switchboard in New York,Stating That Bomb Planted in Ginna Plant in Retaliation for Attempted Murder on Highway 490 ML20249A0931978-01-25025 January 1978 PNO-78-013:on 770125,unit Was Shutdown from 100% Power Due to Leak in One Steam Generator.Licensee Made Decision to Shutdown for Repairs,Although Leak Rate Did Not Exceed TS Limit.State of Ny Informed ML20207G5861977-11-17017 November 1977 PNO-77-201:on 771116,urgent Failure Alarm Occurred on Rod Control Sys,Indicating Logic Problem in CRD Sys.Reactor Shutdown from 100 Percent Power to Cold Shutdown Condition commenced.In-motion of Control Rods Determined Operable ML20236E9101977-08-18018 August 1977 PNS-77-032:on 770816,canoe Capsized W/Two Men Aboard About 100 Feet Offshore Near Plant Discharge Canal to Lake Ontario.One Man Swam Ashore & Climbed Over Security Fence & Called for Help Over Loudspeaker.Other Man Was Rescued ML20151X7111977-07-0606 July 1977 PNO-77-121:on 770705,unit Was Shutdown from 100% Power,Due to Identified Tube Leakage from RCS to Secondary Sys in One of Two Sgs.Outage Duration Expected to Be Two Weeks.Media Interest Expected ML20249B0281976-01-29029 January 1976 PNO-76-018:on 760129,reactor Shutdown Due to Increase Vibration on Two Low Pressure Turbine Bearings.Extent of Problem Not Known.Exam of Bearings Will Be Accomplished During Weekend After Turbine Disassembly ML20236W7901975-12-30030 December 1975 PN-75-157:on 751230,unscheduled Shutdown Completed Due to Increasing Tube Leakage from B Sg.Load Reduction Initiated.Duration of Shutdown Expected to Be Approximately Six Days.State of New York Kept Informed ML20236U2371975-06-18018 June 1975 PN75-037:on 750617,turbine Was Manually Tripped as Result of Excessive Feedwater Piping Vibration.Visual Insp Revealed No Apparent Damage to Pipe Restraints or Containment Penetrations.Some Instrument Sensing Lines Inoperable 1988-06-22
[Table view] Category:TEXT-INSPECTION & AUDIT & I&E CIRCULARS
MONTHYEARIR 05000244/19990071999-09-20020 September 1999 Insp Rept 50-244/99-07 on 990719-23 & 0802-06.NCVs Noted. Major Areas Inspected:Maint & Engineering ML20217L9861997-08-15015 August 1997 Notice of Violation & Proposed Imposition of Civil Penalty in Amount of $55,000.Violation Noted:Vehicle Barriers Deployed Outside Outer Isolation Zone Would Not Prevent Malicious Use of Vehicle to Gain Entry to Protected Areas IR 05000244/19970081997-07-16016 July 1997 Insp Rept 50-244/97-08 on 970527-30.Apparent Violations Being Considered for Escalated Ea.Major Areas Inspected: Conduct of Security & Safeguards Activities,Status of Security Facilities & PA Barriers & Vehicles Barrier Sys ML20132H0791996-12-13013 December 1996 Notice of Violation & Proposed Imposition of Civil Penalty in Amount of $100,000.Violation Noted:Prior to 960803, Measures Not Established to Assure That Certain Conditions Adverse to Quality Not Promptly Identified & Corrected IR 05000244/19900211990-10-24024 October 1990 Physical Security Insp Rept 50-244/90-21 on 900910-14. No Violations Noted.Major Areas Inspected:Onsite follow-up of Previously Indentified Items,Mgt Support & Security Program Plans & Audits ML20246E2561989-04-28028 April 1989 Notice of Violation from Insp on 890313-17.Violation Noted: Design Criteria & Safety Analysis for PORV Block Valve Replacement,To Be Performed During 1989 Outage,Did Not Address Operability Qualification of Replacement Valves PNO-I-88-057A, identified Radioactive Contamination on Contractor Exiting Facility Protected Area.Contamination Also Identified in Individual Home & co-worker Car.Caused by Inadequate Monitoring Before Leaving Restricted Area1988-06-22022 June 1988 PNO-I-88-057A:identified Radioactive Contamination on Contractor Exiting Facility Protected Area.Contamination Also Identified in Individual Home & co-worker Car.Caused by Inadequate Monitoring Before Leaving Restricted Area IR 05000244/19870281988-01-25025 January 1988 Partially Withheld Physical Security Insp Rept 50-244/87-28 on 871116-20 (Ref 10CFR2.790 & 73.21).No Violations Noted. Major Areas Inspected:Plan & Implementing Procedures, Organization,Program Audits & Records & Repts IR 05000244/19870221987-11-24024 November 1987 Exam Rept 50-244/87-22OL During Week of 871005.Exam Results: Six Senior Reactor Operators & Four Reactor Operators Passed All Exams & One Reactor Operator Failed Written Exam IR 05000244/19870211987-09-29029 September 1987 Insp Rept 50-244/87-21 on 870831-0904.No Violations Noted. Major Areas Inspected:Review of Licensee Action on Previously NRC Identified Concerns,Followup of Generic Ltr 83-28,Item 4.1 & Qa/Qc Interfaces IR 05000244/19870191987-08-28028 August 1987 Insp Rept 50-244/87-19 on 870727-31.Violation Noted.Major Areas Inspected:Occupational Radiation Protection Program, Including Status of Previously Identified Items,Organization & Mgt Controls,Audits & External Exposure Control ML20212R5131987-04-20020 April 1987 PNS-i-87-006:on 870420,bomb Threat Received by Monroe County Police Emergency Notification Dispatcher.Security Personnel Posted on Plant Access Roads to Verify Id Prior to Access to Plant.State & Local Police Patrolled Area IR 05000244/19870061987-03-24024 March 1987 Insp Rept 50-244/87-06 on 870224-27.No Violations Noted. Major Areas Inspected:Activities Associated W/Steam Generator Exams & Maint,Inservice Insp & Licensee Actions on Previous Insp Findings IR 05000244/19870051987-03-24024 March 1987 Insp Rept 50-244/87-05 on 870224-27.No Violations Noted. Major Areas Inspected:Status of Previously Identified Items, Organization & Mgt Controls,Training & Qualification of New Personnel,External & Internal Exposure Control & ALARA IR 05000244/19870021987-02-18018 February 1987 Insp Rept 50-244/87-02 on 870104-0207.No Violations Noted. Major Areas Inspected:Licensee Action on Previous Findings, Review of Plant Operations,Operational Safety Verification, Surveillance Testing,Plant Maint & LERs IR 05000244/19870011987-02-0404 February 1987 Insp Rept 50-244/87-01 on 870105-09.No Violations Noted. Major Areas Inspected:External Exposure Control,Internal Exposure Control,Control of Radioactive Matl & Contamination & Surveys & Monitoring ML20212M1901987-01-16016 January 1987 Safety Insp Rept 50-244/86-22 on 861215-19.No Violations or Deviations Noted.Major Areas Inspected:Licensee Response to Previous Insp Findings & Effectiveness of Licensee Correction Action Program IR 05000244/19860211987-01-12012 January 1987 Insp Rept 50-244/86-21 on 861109-870103.No Violations Noted. Major Areas Inspected:Licensee Actions on Previous Findings, Review of Plant Operations,Operational Safety Verification, Surveillance Testing & Plant Maint IR 05000244/19860121986-10-0909 October 1986 Emergency Preparedness Insp Rept 50-244/86-12 on 860826-29. Violation Noted Re Ability to Fully Staff & Augment Emergency Response Organization in Timely Manner IR 05000244/19860131986-10-0202 October 1986 Insp Rept 50-244/86-13 on 860909-11.No Violation Noted.Major Areas Inspected:Annual Emergency Preparedness Exercise Performed on 860910 PNO-I-86-058, on 860729,reactor Manually Tripped from 100% Power Due to Break in Drain Line from Main Steam Reheater 2A to Feedwater Heater 5A.Cause Under Investigation.Licensee Actions Under Review1986-07-29029 July 1986 PNO-I-86-058:on 860729,reactor Manually Tripped from 100% Power Due to Break in Drain Line from Main Steam Reheater 2A to Feedwater Heater 5A.Cause Under Investigation.Licensee Actions Under Review ML20140B0401986-01-0808 January 1986 Exam Rept 50-244/OL-85-23 on 851111-15.Exam Results:All Candidates Passed Both Written & Oral Portions of Exam PNO-I-85-085A, on 851106,licensee Secured from Unusual Event Declared Due to Automatic Actuation of Cable Tunnel Deluge Sys.Caused by Faulty Printed Circuit Card.Ground on Nonvital Bus Damaged by Deluge Sys Corrected1985-11-0707 November 1985 PNO-I-85-085A:on 851106,licensee Secured from Unusual Event Declared Due to Automatic Actuation of Cable Tunnel Deluge Sys.Caused by Faulty Printed Circuit Card.Ground on Nonvital Bus Damaged by Deluge Sys Corrected PNO-I-85-085, on 851106,fire Protection Deluge Sys in Cable Tunnel Automatically Actuated.Smoke Smelled at Scene.Sys Isolated After 10 Minutes of Operation.Visual Insp of Cable Tunnel Revealed No Apparent Damage1985-11-0606 November 1985 PNO-I-85-085:on 851106,fire Protection Deluge Sys in Cable Tunnel Automatically Actuated.Smoke Smelled at Scene.Sys Isolated After 10 Minutes of Operation.Visual Insp of Cable Tunnel Revealed No Apparent Damage IR 05000244/19850201985-10-22022 October 1985 Insp Rept 50-244/85-20 on 850925-27.No Violation Noted.Major Areas Inspected:Emergency Preparedness & Annual Emergency Exercise Performed on 850926 ML20128L0521985-07-18018 July 1985 PNS-I-85-010:on 850718,safeguards Contingency Plan Drill Will Be Held.Exercise Will Test Command/Control, Communications & Response Force Mobilization Developed by State of Ny Emergency Mgt Agency IR 05000244/19850111985-07-11011 July 1985 Exam Rept 50-244/85-11 on 850624.Exam Results:All Candidates Passed.No Generic Deficiencies Noted IR 05000244/19820131982-07-20020 July 1982 IE Insp Rept 50-244/82-13 on 820628-0701.No Noncompliance Noted.Major Areas Inspected:Followup on IE Circular 80-21, Verification of Core load,post-refueling Startup Testing & Control Rod Worth Measurements & Predications IR 05000244/19820111982-06-18018 June 1982 IE Insp Rept 50-244/82-11 on 820517-19.No Noncompliance Noted.Major Areas Inspected:Environ Monitoring Programs for Operation Including Mgt Controls & QC of Analytical Measurements ML20054K9011982-06-16016 June 1982 Notice of Violation from Insp on 820501-31 IR 05000244/19820101982-06-15015 June 1982 IE Insp Rept 50-244/82-10 on 820501-31.Noncompliance Noted: Failure to Properly Implement & Track QA Surveillance Repts ML20236L5201979-10-24024 October 1979 PNS-I-79-005:on 791023,unidentified Male Called Rochester Gas & Electric Corp Switchboard in New York,Stating That Bomb Planted in Ginna Plant in Retaliation for Attempted Murder on Highway 490 ML20249A0931978-01-25025 January 1978 PNO-78-013:on 770125,unit Was Shutdown from 100% Power Due to Leak in One Steam Generator.Licensee Made Decision to Shutdown for Repairs,Although Leak Rate Did Not Exceed TS Limit.State of Ny Informed ML20207G5861977-11-17017 November 1977 PNO-77-201:on 771116,urgent Failure Alarm Occurred on Rod Control Sys,Indicating Logic Problem in CRD Sys.Reactor Shutdown from 100 Percent Power to Cold Shutdown Condition commenced.In-motion of Control Rods Determined Operable ML20236E9101977-08-18018 August 1977 PNS-77-032:on 770816,canoe Capsized W/Two Men Aboard About 100 Feet Offshore Near Plant Discharge Canal to Lake Ontario.One Man Swam Ashore & Climbed Over Security Fence & Called for Help Over Loudspeaker.Other Man Was Rescued ML20151X7111977-07-0606 July 1977 PNO-77-121:on 770705,unit Was Shutdown from 100% Power,Due to Identified Tube Leakage from RCS to Secondary Sys in One of Two Sgs.Outage Duration Expected to Be Two Weeks.Media Interest Expected ML20249B0281976-01-29029 January 1976 PNO-76-018:on 760129,reactor Shutdown Due to Increase Vibration on Two Low Pressure Turbine Bearings.Extent of Problem Not Known.Exam of Bearings Will Be Accomplished During Weekend After Turbine Disassembly ML20236W7901975-12-30030 December 1975 PN-75-157:on 751230,unscheduled Shutdown Completed Due to Increasing Tube Leakage from B Sg.Load Reduction Initiated.Duration of Shutdown Expected to Be Approximately Six Days.State of New York Kept Informed ML20236U2371975-06-18018 June 1975 PN75-037:on 750617,turbine Was Manually Tripped as Result of Excessive Feedwater Piping Vibration.Visual Insp Revealed No Apparent Damage to Pipe Restraints or Containment Penetrations.Some Instrument Sensing Lines Inoperable 1999-09-20
[Table view] |