r OBaHelle Pacific Northwest Laboratones P.O. Dos 999 Rahland, hhmgton U.5.A. 99352 Telephone 15091 u n man June 27, 1985 Mr. Carl Berlinger Division of Licensing U.S. Nuclear Regulatory Commission 7920 Norfolk Avenue Bethesda, Maryland 20014

Dear'Mr. Berlinger:

SUBJECT:

TDI DIESEL ENGINE PROJECT (FIN 82963) --TRANSMITTAL OF TECHNICAL EVALUATION REPORT " REVIEW 0F ENGINE BASE AND BEARING CAPS FOR TRANS-AMERICA DELAVAL DSRV-12, DSRV-16, AND DSRV-20 DIESEL ENGINES" DATED JUNE 1985 (PNL-5200-12 REV. 1)

Enclosed for your use are 10 copies of the subject PNL technical evaluation report. Other copies also have been distributed as noted on the last page of the report.

The principal PNL consultants and PNL staff engineers who participated in the engine base and bearing caps evaluation are S. H. Bush, B. J. Kirkwood, W. W.

Laity, F. R. Zaloudek, S. D. Dahlgren, and S. G. Pitman.

Sincerely, o

e W. W. Laity PNL Project Manager WWL:ri

Enclosures:

cc: As noted on distribution for report.

9507100187 850627

- Ow,,g6 i

903 e

I I I

r OBattelle Pacitic Northwest Laboratories P.O. Ilos 999 Ra hiand, Washington U.S.A. 99352 Telephone (509)

Telex 15-2874 Mr. Carl Berlinger Division of Licensing U.S. Nuclear Regulatory Commission 7920 Norfolk Avenue Bethesda, Maryland 20014

Dear'Mr. Berlinger:

SUBJECT:

TDI DIESEL ENGINE PROJECT (FIN 82963) --TRANSMITTAL 0F TECHNICAL EVALUATION REPORT " REVIEW OF ENGINE BASE AND BEARING CAPS FOR TRANS-AMERICA DELAVAL DSRV-12, DSRV-16, AND DSRV-20 DIESEL ENGINES" DATED i

JUNE 1985 (PNL-5200-12 REV. 1)

Enclosed for your use are 10 copies of the subject PNL technical evaluation report. Other copies also have been distributed as noted on the last page of the report.

The principal PNL consultants and PNL staff engineers who participated in the l

engine base and bearing caps evaluation are S. H. Bush, B. J. Kirkwood, W. W.

Laity, F. R. Zaloudek, S. D. Dahlgren, and S. G. Pitman.

Sincerely,

?

o W. W. Laity l

PNL Project Manager l

WWL:ri

Enclosures:

cc: As noted on distribution for report.

8507100187 850627 7

aoocn Oso,g 6 903; l l

.