Responds to Ltr to F Mcgoldrich of State Dept Re Executive Branch Study Rept Entitled, Definition of Bounding Physical Tests Representative of Transport Accidents -- Air & Marine, Prepared by IIT Research Inst
ML20128H475
Person / Time
Issue date: 01/15/1993
From: Taylor J
NRC OFFICE OF THE EXECUTIVE DIRECTOR FOR OPERATIONS (EDO)
To: Geoffrey Miller
HOUSE OF REP.
References
CCS, NUDOCS 9302170047
Download: ML20128H475 (3)


Text

. - _.

[

'o UNITED STATES

'g

["

g NUCLEAR REGULATORY COMMISSION E

W ASHING TON, D. C. 20555 5,

January 15, 1993 The Honorable George Miller, Chairman Committee on Natural Resources United States House of Representatives Washington, D.C.

20515

Dear Chairman Miller:

I am responding to your letter to Mr. Fred McGoldrick of the U.S. Department of State regarding the Executive Branch study required by Public Law 102-486.

In your letter you identified a report, " Definition of Bounding Physical Tests Representative of Transport Accidents -- Air and Marine," prepared for the Nuclear Regulatory Commission in 1983 by the Illinois Institute of Technology's Research Institute (IITRI).

You requested that this report be reviewed prior to completion of the Executive Branch study.

The IITRI report has been reviewed in preparation of the Executive Branch study.

In 1979, the NRC was concerned with frequent public criticism that regulatory test requirements and performance standards for packages containing large quantities of radioactive material were not realistically linked to possible severe accident conditions.

For example, survival of a 30-ft drop on an unyielding surface without incurring significant leakage did not appear to be a stringent collision standard.

The NRC initiated a multiphase effort (the Modal Study) to evaluate the extent to which regulatory tests and performance standards bounded high severity transportation accidents, and to evaluate the residual risk from any accidents which may not be bounded.

The initial phase of this effort resulted in two studies:

(1) Severe Rail and Truck Accidents:

Toward a Definition of Boundina Environments Lo.r Transoortation Packaaes, by o

Ridihalgh, Eggers and Associates (REA); and (2) Def_Ln.ilion of Boundina Physical Tests Represent _aljve of Transoort Accidents - Air and Marine, by the Illinois Institute of Technology Research Institate (IITRI).

IITRI submitted their final report to the NRC in 1983. The IITRI_ report developed a series of physical tests, based on an analysis of marine and air accident data for 1970-1979. These included a crush test, penetration test, slash test and immersion test for extremely severe marine accident conditions, as well as a separate test sequence comprised of a fire test, hose stream test, and an immersion test. A separate deep submersion test was also propcsed. The tests specified by the IITRI study appear to be more severe than the traditional tests recommended and adopted by IAEA member states.

However, the study did not develop post-test acceptance criteria. While the tests seem more severe, the level of safety afforded by the suggested tests was not evaluated, and could not be determined without corresponding acceptance criteria.

In the area concerning shipbnard fires, the IITRI study _ concluded that the current IAEA packaging requirement that packages withstand a 30-minute _1475 F fire would be more than adequate for below-deck fires. This conclusion is particularly germane to plutonium shipments, where the greatest risk is O

9302170047 93o11 6

PDR ORG NE ED l

t PDR

\\

___m__________

_m

6 4

Tht: Honorable George Miller from respirable particles, such as those that may be produced in fires.

The llTRI study based this conclusion on its analysis of a collision between a container ship (the Sea Witch) and an oil tanker which occurred in New York Harbor in 1973, an accident which is characterized by the Coast Guard (according to the IITRI report) as a " worst-case" accident.

About the time the llTRI report was submitted, a reconsideration of program stratt.gy led to a redirection of the Modal Study.

This redirection was based on program costs and timing, since at that time, large numbers of road and rail spent fuel shipments were being projected (e.g., shipments to a monitored retrievable storage facility), many of which were anticipated to be made in new package designs.

As a result, neither the IITRI or the REA study was pursued beyond its initial effort to develop package qualification tests (e.g., no efforts were undertaken to establish post-accident acceptance criteria).

Because of the redirection, neither the IITRI or REA reports were subjected to normal peer review.

Instead, NRC redirected its effort towards determining the adequacy of protection provided by spent fuel packages (built to Type B standards) when subjected to historically severe highway and railway accident conditions.

The resulting study (NUREG/CR-4829) showed that spent fuel packages, which are designed to the same international standards used for plutonium packages, would perform their safety functions under severe accident conditions.

In our consulting role in toe Executive Branch study, the staff reviewed the IITRI report as well as Department of Energy and NRC risk studies previously performed.

The staff concluded that due to the low probability of severe marine accidents (as acknowledged in the :ITRI report) and the minimal risk posed by such accidents, the current IAEA package standards provide adequate public health and safety for plutonium shipments by sea.

We hope that this addresses your concerns. We expect that the Executive Branch study will be issued shortly.

Sincerely,

/

.W' V ecutiveD[irector es

. Ta or

/

for Operations l

n, i 15-1902 12134 12 7o775 uc.s I

CongrtWW of the En(ttb $Ptates assUnsten. BC 20515

~

Deesmher 14, 1992 The Honorable Fred McGoldrick Acting Deputy Assistant Soorstary Nuclear Energy and Energy Technology Affairs Bureau ot oceans and International Environmental and Scientific Affaire United States Department of State Maahington, D.C.

20520 Dear Mr. McGolcieickt

' Definition of Bounding Physical Enclosed is a copy of a report, Tests Representativo of Transport Accidents. ~ Air and Marine,'

We believe,the report that was recently brought to our attention.

is highly relevant to the Executive Branch study now being carried out in consultation with the ~ Nuclear Regulatory Commission (NRC) pursuant to Public Law 102-486.

prepared for the NRC in 1983, includes & detailed set This report, of tests for determ*.ning whether casks used for transporting could withats&d extremelyz severe radioactive materials by set, Unfortunately, although the report was completed under accidents.

contract for NRC's office of Nuclear Requietory Research by a team at the Illinois Institute of technology's Rosmarch Institute (IITRI), the tests proposed in the report hava never been pursued.

This report was part of the Modal Study, a project begun by NRC in-1978 to examine safety issues related to various modes of transportatio,n of radioactive materials.

The IITRI team ha.s identified both ' historical and hypothetical scenarion for severe air and marine transport. accidents involving

=

radioactive material coatainers and used this data to develop scenarios for

" extremely severs credible. accidents for each shipping mode."

IITRI then developed tests for radioactive material casks that would simulate the stressoa that actually occur in such

. severs accidents.

It.

appears that-the report satisfactorily defined a

maximum credible accident scenario involving plutonium transport based upon a survey of maritime accidents and an assessment of the nest severs conditions under The study further designed-which such accidents have occurred.

appropriate test procedures to replicate such conditions.

f

+.,

..... ~.. ~.- -

v CON 3RESSIONAL.CORMSPONDEWCE SYSTEM DOCUMENT.PREPARATICM CIECKLIST This checklist is be submitted with-eash document (or group of

Qs/As) sent for 6 ing into the ccs.

ottA Im/K4W.dbZ{/4 1.

BRIEF DESCRIPTION OF DOCUMENT (S)

P.'~

M correspondenses yeariagan(Os/Aak 2.

TYtt or--

3.

DoccMzNT cont 30L sensitive '(Nac caly)

N Won-Seasitive' 4.

CONGRESSIONAL COMMITTEI~ and SU3 COMMITTEES (if applicable)

Congressional committee Subcommittee S.

SUBJECT CODES (a)

(b)

(c) l l

s.

soumCE OF DoCcxENTS (a) 8880 (document name (b)

Y Ssaa..

(e)-

Atlashments (d)

Rakey (e) other 7.

SYSTEM Los DATES bl1 33 Date oca esat dooumont to ces (a)

L (b)

Dato ccs. Esseivees doeunaat

-(e)

Data returned to Oca, for additional infesiaation:-

(d)

Data resubmitted by-oca to cc8 e

(et Data entered late-cca by (f)-

Date ocA notified that document is in ccS-j 8.--COMMENTS

.