1 s
FEB 0 1993 Docket No. 50 29 License No. DPR-3 Mr. Jay K. Thayer Vice President and Manager of Operations Yankee Atomic Electric Company 580 Main Street Bolton, Massachusetts 01740-1398
Dear Mr. Thayer:
SUBJECT:
10 CFR 50.54 QUALITY ASSURANCE PROGRAM CHANGE REVIEW
References:
Letter dated October 21,1992, from Mr. C, R. Clark to the U. S. Nuclear Regulatory Commission transmitting Revision 23 to the Yankee Atomic Electric Company Operational Quality Assurance Program (YOQAP 1-A)
We received your 10 CFR 50.54(a) submittal referenced above, transmitting Revision 23 to the Quality Assurance Program for Yankce. The Region I staff has reviewed this submittal in accordance with 10 CFR 50.54(a) and determined that the changes to the Quality Assurance Program are acceptable in that the Quality Assurance Program continues to satisfy the criteria of Appendix B of 10 CFR Part 50. If there are changes to other operative QA commitments existing in docketed correspondence outside of the QA program description, you are obligated to notify this office. Implementing such changes should be based on 10 CFR 50.54(a)(3). The effectiveness of your Quality Assurance Program and procedure implementation will continue to be the subject of routine regional inspections.
If you have any questions concerning the above, please contact Fred Bower at (215) 337-5328, Sincerely, _
lfas, b, h
A
~.
ist
.ht J
Lee H. Be nhausen, Chie '
Operations Branch Division of Reactor Safety OFFICIAL RECORD COPY G:YAQA1021 3
9302170037'930208 '
l
.PDR.:ADOCK' 05000029 P
.png; KW l
f
s Mr. Jay K. Thayer 2
FEB 21993 cc:
A. Kadak, President and Chief Executive Officer N. St. laurent, Plant Superintendent R. Itallisey, D panment of Public Health, Commonwealth of Massachusetts T. Dignan, Esquire J. Grant, Senior Licensing Engineer R. Sedano, Commissioner, Vermont Department of Public Service T. Rapone, Massaa.husetts Executive Office of Public Safety R. Gelder, New Engl:.nd Conference of Public Utilities Commissioners, Inc.
Citizens Awareness Network Public Document Room (PDR)
Local Public Document Room (LPDR)
Nuclear Safety Informstion Center (NSIC)
NRC Resident Inspector Commonwealth of Masechusetts, SLO Designee State of Vermont, SLO Designee OFflCl AL RECORD COPY G:YAQA1021
t
\\"
FEB 2 1993 Mr. Jay K. Thayer 3
bec:
Region i Docket Room (with concurrences)
E. Kelly, DRP N. Perry, SRI - Yankee Rowe (w/ concurrences)
H. Eichenholz, SRI - Vermont Yankee J. Linville, DRP V. McCree, OEDO M. Faittile, NRR W. Butler, NRR L. Bettenhausen, DRS N. Blumberg, DRS F. Bower, DRS V. Curley, DRS DRS File (s)
[/
/)
l&
} RI:
RI:DRS[Ji S
RI:DRS Bower /ms Blumberg IKttenhaus fubH/]
@2/93
.QLl2/93 1/g93 OFFICIAL RECORD COPY G:YAQA1021 6