FUEL RACK CRITICALITY REANALYSIS Dave-To satisfy the Cycle 8 er argy plan, RBS intends to increase the maximum enrichment allowed for spent fuel to be stored in the high density spent fuel storage racks from 3.8 to 4.8 wt% U-235.
Our reanalysis shows this to be acceptable in that it maintains Keff below 0.95 under all normal and abnormal conditions. Among other things, the reanalaysis was based on the " SCALE-4" code package (vice the KENO code which was used previously). The overall reanalysis methodology is identical to that used in similar reanalyses at W3 and ANO.
W3 and ANO rec'd NRC approval for this change. As far as I can tell, NRC approval was necessary because enrichment was included in the TS's (which is not the case here at RBS).
So far,it appears that we can implement this analysis methodology change under 10CFR50.59 (no USQ). Do you or the staff have any views on this matter?
CC:
ud 1.intemet3("BA R RY.M. B U R M EISTER@ entergy.com","ps...
)
l 9610090156 961002 j
PDR ADOCK 05000458 P
PDR l
a 0
Regeived from igate.nrc. gov by irm12 (5.x/TMD1.7) j id AA01588; Wed,2 Oct 1996 20:00:00 -0400 Received: from NRC by smtp-gateway (8.7.6/8.7.6) with SMTP id UAA24961 for
<diw@nrc. gov >; Wed,2 Oct 1996 20:00:05 -0400 (EDT)
From: tgates@entergy.com Received: from cc3smtplink by entergy.com (SMI-8.6/SMI-SVR4) id SAA23892; Wed,2 Oct 199618:59:25 -0500 Received: from ccMail by cc3smtplink (SMTPLINK V2.10.08) id AA844308366; Wed,02 Oct 9618:10:09 CST Date: Wed,02 Oct 9618:10:09 CST Message-Id: <9609028443.AA844308366@cc3smtplink>
To: dlw@nrc. gov Cc: BARRY.M.BURMEISTER@entergy.com, psicard@entergy.com
Subject:
FUEL RACK CRITICALITY REANALYSIS I