ML20128G164

From kanterella
Jump to navigation Jump to search
Requests That Paper Entitled, Experimental Evaluation of Flooding Between Hot Leg & SG Inlet Plenum of PWR During Small LOCAs Be Withheld,Per 10CFR2.790
ML20128G164
Person / Time
Site: 05200003
Issue date: 02/04/1993
From: Liparulo N
WESTINGHOUSE ELECTRIC COMPANY, DIV OF CBS CORP.
To: Borchardt R
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML19303F285 List:
References
AW093-407, AW93-407, NUDOCS 9302120173
Download: ML20128G164 (9)


Text

_ _ _ _ _ _ _ -.

(q) i Westinghouse Energy Systems tu m

[l8Clfl0 C0fp0 fall 0n h"

  • W W" W "M W AW 93 407 February 4,1993 Document Control Desk U.S. Nuclear Regulatory Commission Washington, D.C. 20555 ATTEN~110N: MR. R. W. BORCllARDT APPL.ICATION FOR WIT 111101 DING PROPRIETARY INFORMATION FROM Plfill.lC DISCLOSURR SUIUECT:

INFORMATION ON AIR WATER FLOODINO EXPER!MENTS

Dear Mr. Ikirchardt:

The application for withholding is submitted by Westinghouse Electric Corporation (" Westinghouse")

pursuant to the provisions of paragraph (b)(1) of Section 2.790 of the Commission's regulations. It contains commercial strategic information proprietary to Westinghouse and customarily held in confidence.

The proprietary material for which withholding is being requested is identified in the proprietary ven, ion of the subject ceport. In conformance with 10CFR Section 2.790, Affidavit AW 93-407 accornpanics this application for withholding sciting forth the basis on which the identified proprietary information may be withheld from public disclosure.

Accordingly, it is respectfully requested that the subject information which is proprietary to Westinghouse be withheld from publ!n disclosure in accordance with 10CFR Section 2.790 of the Commission's regulations.

Correspondence with respect to this application for withholding or the accompanying affidavit should reference AW 93 407 and should be addressed to the undersigned.

Very truly yours, 1

c<

N. J. Liparuto, Manager Nuclear Safety And Regulatory Activities

/nja ec:

M. P. Siemien Office of the General Counsel, NRC L Barnett NRC (121{5) --

om^

9302120173 930204 PDR ADOCK 05200003 A

FDR-

I I

COPYRIGilT NOTICE The reports transmitted herewith each bear a Westinghouse copyright notice. The NRC is permitted to make the number of copics of the information contained in these reports which are necessary for its internal use in connection with generic and plant specific reviews and approvals as well as the issuance, denial, amendment, transfer, renewal, modification, suspension, revocation, or violation of a license, permit, order, or regulation subject to the requirements of 10 CFR 2.790 regarding restrictions on public disclosure to the extent such infortnation has been identified as proprietary by Westinghouse, copyright protection not withstanding. With respect to the non proprietary versions of these reports, the NRC is permitted to make the number of copics beyond those necessary for its internal use which are necessary in order to have one copy available for public viewing in the appropriate docket files in the public document room in Washington, D.C. and in local public document rooms as may be required by NRC regulations if the nurnber of copics submitted is insuf0cient for this purpose. The NRC is not authorized to make copics for the personal use of members of the public who make use of the NRC public document rooms. Copics made by the NRC must include the copyright notice in all instances and the proprietary notice if the original was identified as proprietary.

U U$dd

.;- - :-.. -., ~.., -, -.. -... _ - -. _,.,.. -...,,....,...... -.,

l P

PROPRIETAltY INI'OllMATION NOTICIC Transmitted herewith are proprietary and/or non proprietary versions of documents furnished to the NRC in connection with requests for generic and/or plant specific review and approval.

In order to conform to the requirements of 10CFR 2.790 of the commission's regulation concerning the protection of proprietary information so submitted to the NRC, the information which is proprietary in the proprietary versions is contained within brackets and where the proprietaty inforruation has been deleted in the non proprietary versions on the brackets rernain, the infortnation that was contained within brackets and where the proprietary information has been deleted in the non proprietary versions only the brackets remain, the information that was contained within the brackets in the proprietary versions having been deleted. The justification for claiming the information so designated as proprietary is indicated in both versions by means of lower case letters (a) through (f) contained within parentheses h)cated as a superscript immediately following the brackets enclosing each item of information being identified as proprietary or in the margin opposite such information. These lower case letters refer so the types of information Westinghouse customarily holds in confidence identified in Section (4)(ii)(a) through (4)(ll)(f) of the affidavit accompanying this transmittal pursuant to 10CFR2.790(b)(1),

awr

l

.e AW.93 407 AFFIDAVIT COMMONWEALTil 0F PENNSYLVANIA:

ss COUNTY OF ALLEGHENY:

Ikfore me, the undersigned authority, personally appeared Peter J. Morris, who, being by me duly sworn according to law, deposes and says that he is authorized to execute this Affidavit on behalf of Westinghouse Electric Corporation (" Westinghouse") and that the averments of fact set forth in this Affidavit are true and corice to the best of his knowledge, information, and belief:

hmY Peter J. Morrks, Manager Strategic Safety and Regulatory Issues Sworn to and subscribed before me this day of YdW4A4

.1993

$Ahuws ~)%f. f6W

/

Notary Public tktrialEskil Lamho M P(A:c,tkt Ptth Mannxheolkyo, Couny My ComtArbn Expes c 14.1995 Menoor.Pararyhimu AwmianiofIetvw fl17&A

y AW.93 407 x

(1)

I am Manager, Strategic Safety and Regulatory issues, in the Nuclear and Advanced Technology Division, of the Westinghouse Electric Corporation and as such,I have been

.i specifically delegated the function of reviewing the proprietary information sought to be withheld from public disclosure in connection with nuclear power phnt lleensing and rulemaking proceedings, and am authorized to apply for its withholding on behalf of the Westinghouse Energy Systems Business Unit.

(2)

I am making this Affidavit in conformance with the provisions of 10CFR Section 2.790 of the Commission's regulations and in conjunction with the Westinghouse application for withholding accompanying this. Affidavit.

(3)

I have personal knowledge of the criteria and procedures utillied by the Westinghouse Energy Systems Business Unit in designating information as a trade secret, privileged or as confidential commercial or financial information.

(4)

Pursuant to the provisions of paragraph (b)(4) of Section 2.790 of the Comrnission's regulatform, the following is furnished for consideration by the Commission in determining whether the information sought to be withheld from public disclosure should be withheld.

(i)

The information sought to be withheld imm public disclosure is owned and has been held in con idence by Westinghouse, r

(ii)

De information is of a type customarily held in confidence by Westinghouse and not.

customarily disclosed to the public. Westinghouse has a rat.lonal basis for determining the types of information customarily held in confidence by it and, in that connection, utilizes a system to determine when and whether to hold certain types of information in confidence. The application of that system and the substance of that system l.

constitutes Westinghouse policy and provides the rational basis required.

Under that system, information is held in confidence if it falls in one or more of several types, the release of which might result in the loss of an' existing or potential competitive advantage, as follows:

l l.

0778A

.l

4 4

4 AW.93 407 6

(a)

The information reveals the dist!riguishing aspects of a process (or component, -

f structure, tool, method, etc.) where prevention of its us.e by any of Westinghouse's competitors without lleense from Westinghouse constitutes a competitive economic advantage over other companies.

1 (b)

It consists of suppotting data, including test data, relative to a process (or compment, structure, tool, method, cre.), the application of whleh data securrs '

a competitive economic odvantage, e.g., by optimiratic,n or improvat matketability.

(c)

Its use by a competitor wouhl reduce hi, expenditure of resources or improve his competitive position in ibe design, manufacture, shipnent, installation,.

assurance of quality, or lleensing a similar product.

(d)

It reveals cost or price information, production capacities, budget levels, or commereht strategies of Westinghouse, its customers or suppliers.

(c)

It reveals aspects of past, present, or future Westinghouse or customer funded development plans and programs of potential commercial value to Westinghouse.

(f)

It contains patentable ideas, for which patent protection may be desirable.

There are sound policy reasons behind the Westinghouse system which include the following:

(a)

The use of such information by Westinghouse gives Westinghouse a competitive advantage over its competitors, it is, therefore, withheld from disclosure to protect the Westinghouse competitive position.

(b)

It is information which is marketable in many ways. The extent to which such information is available to competitors diminisks the Westinghouse ability to sell pnxlucts and services involving the use of the information.

0774A

v n

./

AW.93 407 y

(c)

Use by our competitor would put Westinghouse at a cornpetitive disadvantage j

+

by reducing his exgnditure of resenrces at our expense.

(d)

Each compment of proprietary information pertinent to a pcrticular i

comp:titive advantage is potentially as valuable as the total competit ve i

advantage. If competitors acquire componenta of proprietary infunnation, any one cornponent may tw the key to the entira puule, thereby depriving 7

Westinghouse of a competitive advantage-(c)

Unrestrided dh. closure would jeopardire the position of prominence of p

' Westinghouse in the world maitt, and thereby give a market advantage to the competition of those countries.

(f)

The Westinghouse capacity to mvest corporate assets in research and development depends upon the success in obtaining and maintaining a competitive advantage.

(iii)

The information is being transmitted to the Commission in confidence and, under the provisions of 10CFR Section 2.790, it is to be received in confidence by the l

Commission.

(iv)

The information sought to be protected is not available in public sources or available information has not been previously employed in the same original manner or method to the best of our knowledge and belief.

(v)

Enclosed is Letter ET-NRC-93 3814, February 1993, being transmitted by Westinghouse Electric Corporation (W) letter and Application for Withholding Proprietary infortnation from Public Disclosure, N, J. Liparuto (W), to -

Mr. R. W. Borchardt, Office of NRR, The proprietary information as submitted for use by Westinghouse Electric Corporation is in response to questions concerning the, Ap600 plant and the associated design certification application and is expected to le t

applicable in other licensee submittals in response to certain NRC requirements for justification of licensing advanced nuclear power plant designs.

r 077#A

n.

t e-

.n u v

v 4

-m

.s-

.lm - - - - -,-

++

--,e

AW.93 407 This information is part of that which will enable Westinghouse to:

(a)

Demonstrate the design and safety of the AP600 Passive Safety Systems.

(b)

Establish applicable verification testing methmia.

(c)

Design Advanced Nuclear Power Plants that meet NRC requirements.

(d)

Establish technical and lleensing approaches for tFe AP600 that will ultimately result in a certified design.

(c)

Assist customers in obtaining NRC approval for future plants.

Further this infortnation has substantial commercial value as follows:

(a)

Westinghouse plans to sell the use of similar information to its customers for purposes of meeting NRC requirements for advanced plant lleenses.

(b)

Westinghouse can sell support and defense of the technology to its customers in the licensing process.

Public disclosure of this proprietary infonnai;on is likely to cause substantial harm to the competitive position of Westinghouse because it would enhance the ability of competitors to provide similar advanced nuclear power designs and licensing defense services for commercial power reactors without commensurate expenses. Also, public disclosure of the information would enable others to use the information to meet NRC requirements for licensing documentation without purchasing the right to use the information.

The development of the technology described in part by the information is the result of applying the results of many years of experience in an intensive Westinghouse effort and the expenditure of a considerable sum of money.

ema u

- =,,,,. _. -

a

AW-93 407 in order for competitors of Westinghouse to duplicate this information, similar technical programs would have to be performed and a significant manpower effort, having the requisite talent and experictice, would have to be expended for developing analytical rnethods and receiving NRC approval for those methods.

Further the deponent sayeth not.

r f

s L

,.