February 9, 1993 f,

Docket No. 50-382 Mr. Ross P. Barkhurst Vice President Operations Entergy Operations, Inc.

Post Office Box B Killona, Louisiana 70066

Dear Mr. Barkhurst:

SUBJECT:

CONFIRMATION OF ACTIVITIES ASSOCIATED WITH NRC GENERIC LETTER 89-13,

" SERVICE WATER SYSTEM PROBLEMS AFFECTING SAFETY-RELATED EQUIPMENT" (TAC NO. M74081)

By letter of February 9, 1990, to Louisiana Power bnd 1.ight Company (LP&L)'on the above subject, we addressed the need for confirmation of the implementation of activities at Waterford 3 within 30 days of the implementation.

By letter of January 29, 1993, Entergy Operations, Inc.,

provided this confirmation. We consider this letter and the LP&L letter dated January 29, 1993, as appropriate responses to Generic letter 89-13. Any further followup will be conducted through our inspection activities where appropriate.

This closes our activities under TAC No. M74081.

Sincerely, Q

R

% NdA t

George T. Hubbard, Acting Director Project Directorate'IV-1 Division of Reactor Projects - III/IV/V Office of Nuclear Reactor Regulation cc:

See next page DISTRIBUTION Occket File NRC & Local PDRs PD4-1 Reading D. Wigginton M. Virgilio G. Hubbard P. Noonan ACRS (10) (P-315)

OGC (15B18)

J. Roe PD4-1 Plant File A. B. Beach, RIV V. Hodge n

0FC LA:PD4-1 PM:h0h1 D:PD4-1 d _.

NAME EN55@ah OkiktW GHubbardhsb

(

DATE S /9 /93 2-/3/93 b9/93 1

0FFICIAL RECORD COPY Document Name: WA89-13.ltr e

e20212e m,2026,-

PDR ADOCK 05000302

)

P PDR

.a 6

w t' '

f

'i NUCLEAR REGULATORY COMMISSION

- UNITED STATES

$T y1 WASHINGTON, D.C. 20066 =

s.

e p

      • ++

February 9, 1993-Docket-No. 50e382-t Mr. Ross P. Barkhurst Vice President Operations Entergy Operations, Inc..

Post Office Box B Killona, Louisiana 70066 4

Dear Mr. Barkhitrst:

SUBJFCT:

CONFIRMATION OF ACTIVITIES ASSOCIATED WITH NRC GENERIC LETTER 89-13,;

p

" SERVICE WATER S'ISTEM PROBLEMS AFFECTING-SAFETY-RELATED EQUIPMENT" L

(TAC NO. M74081)'

By letter of February 9, 1990, to Louisiana Power and Light Company (LP&L) on-the above subject, we--addressed the need for confirmation-of the-L implementation of activities at Waterford 3 within 30. days of the l --

implementation.. By letter.of January 29,'1993, Entergy Operations, Inc., ;

provided-this confirmation. We consider this letter and the LP&L -letter dated-.

-January 29, 1993, as appropriate res)onses to Generic Letter 89-13. Any further followup will be conducted t1 rough our inspection activities where E

appropriate.

L This closes our activities under TAC No. M74081.

Sincerely, George T. Hubbard, A: ting Director Project Directorate IV-1

- Division of Reactor. Projects 1-I'II/IV/V

' Office of Nuclear Reactor Regulation' cc:

See next page Y

a s

s

-Mr. Ross P. Barkhurst Entergy Operations, Inc.

Waterford 3 CC:

Mr. Hall Bohlinger, Administrator Regional Administrator, Region IV Radiation Protection Division U.S. Nuclear Regulatory Commitsion Office of Air Quality and Nuclear Energy 611 Ryan Plaza Drive, Suite 1000 Post Office Box 82135 Arlington, Texas 76011 Baton Rouge, Louisiana 70884-2135 Resident Inspector /Waterford NPS Mr. John R. McGaha Post Office Box 822

-l Vice President, Operations Killona, Louisiana 70066 Support Entergy Operations, Inc.

Parish President Cauncil P. O. Box 31995 St. Charles Parish Jackson, Mississippi 39286 P. O. Box 302 Hahnville, Louisiana 70057 William A. Cross Bethesda Licensing Office Mr. Donald C. Hintz, President D

3 Metro Center and Chief Executive Officer Suite 610 Entergy Operations, Inc.

Bethesda, Maryland 20814 P. O. Box 31995 Jackson, Mississippi 39286 l

Mr. Robert B. McGehee Wise,' Carter, Child & Caraway Chairman P.O. Box 651 Louisiana Public Service Commission Jackson, Mississippi 39205 One American Place, ' Suite 1630'-

Baton Rouge, Louisiana 70825-1697 Mr. D. F. Packer General Manager Plant Operations Mr. R. F. Burski, Director 3

Entergy Operations, Inc.

Nuclear Safety P. 0. Box B Entergy' Operations, Inc.

.l Killona, Louisiana 70066 P. O. Box B Killona,-Louisiana 70066 Mr. L. W. Laughlin, Licensing Manager Entergy Operations, Inc.

P. O. Box B Killona, Louisiana 70066 Winston & Strawn Attn:

N. S. Reynolds 1400 L Street, N.W.

Washington, DC ' 20005-3502

-