7 WM Record Fila WM Prc!cctlL3120 JUN 12 $35et No.___
.4 P D R -._ v - -
LPDR _
DISTRIBUTION WM-FW/85/06/12 Distrihution:
,lM F11e X
- 1. !
a
'NMSS r/f jReturn to 50f56.._. __
WMGT r/f REBrowning MEMORANDUM FOR:
Myron H. Fliegel, WMGT MJBell Division of Waste Management MRKnapp LBHigginbotham FROM:
Michael F. Weber, WMGT MHaisfield Division of Waste Management MFWeber & r/f MBlarson Mark Larson, WMGT GGnugnoli Division of Waste Management J0 Bunting WLDam WFord
SUBJECT:
NRC/ TAC MEETING ABOUT HYDROGE0 LOGIC CHARACTERIZATION OF THE MEXICAN HAT AND MONUMENT VALLEY UMTRAP SITES On Wednesday, June 12, 1985, we met with Bill Mason, John Thackston, and John Dupuy of D0E's Technical Assistance Contractor (TAC) and Mark Haisfield (NRC) to discuss proposed hydrogeologic characterization of the Mexican Hat and Monument Valley UMTRAP sites.
Preliminary characterization of the sites indicated potential contamination of shallow groundwater downgradient of both sites.
The proposed characterization activities are intended to characterize this contamination and develop the kinds of information necessary to comply with EPA's guidance in Subpart C of 40 CFR Part 192. Thir; memorandum documents our response to the TAC representatives at the meeting.
The TAC's specific purpose for the meeting was to present the proposed characterization activities and ask NRC whether these activities appeared to be reasonable based on available information.
As depicted in the enclosures, the proposed activities include the installation of approximately 10 additional wells at Mexican Hat and approximately 15 additional wells at Monument Valley.
Most of the meeting focused on optimal locations for these new wells. The TAC stated that well locations will be adjusted following our meeting to optimize the value of information to be collected from the wells.
At the conclusion of the meeting, we stated that the proposed characterization activities constituted a reasonable approach based on information available to us at this time, but that additional characterization may be necessary depending on analyses of results obtained from the new wells or other sources.
The TAC recognized the potential need for an iterative approach for site characterization and stated that they will make their best effort to prepare a defensible evaluation for comparison against the EPA standards.
The TAC also agreed to provide NRC with copies of the proposed Statements of Work (S0W's) and data files consisting of site-specific hydrogeologic information that the TAC has collected at these sites and the Tuba City UMTRAP site.
As a follow-up activity for internal consideration, the TAC asked for our coments on their hydrogeologic evaluation of the Lakeview UMTRAP site.
They
>_ _ _. : ----.h FC :WMGT
!AME:MW:ber
- MLar
)--__:-___________:.__________..____________._______,_____.____________.____________.___________
%TE:85/06/g
- 85/06// / :
+
JUN 121985 WM-39/MFW/85/06/12 consider this evaluation to be a prototype approach for hydrogeologic evaluations of other UMTRAP sites and asked if URF0's approval of the approach would constitute generic acceptance.
We responded that WMGT had not reviewed the Lakeview evaluation because the technical reviews were perfonned by URF0 and that URF0's approval of the Lakeview approach would not necessarily constitute acceptance for other UMTRAP sites reviewed by the technical staff in WMGT.
In light of the TAC's generic interest in NRC's coments on the Lakeview approach, we should consider performing a technical review of the approach.
If you have any questions about our meeting with the TAC, please contact us.
Enclosure:
Maps of Existing and Proposed Wells Enclosures available in DCC.
L pFC :WMGT
- WMGT n____:____________:_____
4AME :MW:ber
- ML
) ATE :85/06/
- 85/06/l1/:
1
JUN 121985 ENCLOSURE A
}f SAN JUAN RIVER l
)
Il MEXICAN /
i l MT I
1
% _-. _ /
s
'928.1
{
di
. 8924 33 919,
(
MEXICAN gu e 929 i*
HA.T SITE 922
, 915 9
TALINGS r *.
e j'"
PILES g
9 909 MLL
{.
& :g BULDINGS a.
I) 83 i
HOUSING AREA
{
)l 0
1/2 1 Mi i
FIGURE 6
- PROPOSED MONITOR WELL LOCATIONS E EXISTING MONITOR WELL LOCATIONS
JUN 1% 198b ENCLOSURE B e eis e e 17 i,\\
i
\\\\
t is l
it 11n ll
'{
g S P RING
.ais
- o i,\\
gs2s e30 A
\\\\.
eeis 0
'0 O seGMwAv 943 AND MEslCAN MAT tis Weiest e
i
.s2, i
5
/
620 y22
{
r-l*
1 fo
[
cAen vAuse wm
..=
/.,M, g -... '.,,< *..a e a e ease g
g,,
3
- ~ :.2 yn::.',4 c~'"'"
l
- a 8 '<A
- uu
{.f,8
". O UOaMEn
'W*
,f*
Tan 5/
/
P E n
... e
~At g t.p+*
,e*
f..
,e**
\\
f
(
i;
._:- /
..r i
MONVWENT seO 2 Wiest 0.75 ML
- J
(
)
ao LEaRoss
.' CORR AL /
0 d
(
g evoosa cMAmes in
q '
)
se
,,,7 SLOPE (DoWNW ARD) 9
-*-- SW T E R MIT T E N T STREAM on WAGM e
a O "a*u s"e *R s o Rim e "n
o 200400 ese een g comenota em 8
SCALE les IEET sw N ARUMP FORM A.
s27 Tsom g ogt,e O l O conewoLaem os CMELLY sAmosTont s23g it ll e APPROXIMATE LOCATION OP PROPOSEO SOREMOLE IN ALLUvlWW h 020
$ APPROxtu ATE LOCAT ON OF PROPOSED s24 SOREMOLE IN SMIN ARUWP PORM ATION A APPROEIM ATE LOCATION OF PROPOSED SOREMOLE IN DE CHELLEY SANOSTONE FIGURE 6 MONUMENT VALLEY SITE MAP WITH EXISTING & PROPOSED MONITOR WELL LOCATIONS
. - _ _ _ _ _. _. _ _ _ _ _