bm8 SIEMENS o.

c ri.

1 September 13,1996 09 I n-LJM:96:072

il:27 i

Washington State Department of Ecology Attn:. Mr. Kim H. Sherwood Water Quality Division 70--I I

15 West Yakima Avenue, Suite 200 Yakima, WA 98902 3401

Dear Mr. Sherwood:

WASTE LIQUID EFFLUENTREPORT August 1996 Measurements of I; quid waste discharges from the Siemens Power Corporation facility to the Richland Municipal Sewerage System are reported herein. As previously communicated to your

)

office, the daily maximum limit for ammonia was exceeded on August 2,3, and 4. The cause, as discussed in the attached report, was related to a valving problem associated with regeneration of the Lagoon 5A IX column. Corrective actions to preclude recurrence will be in place before the next ' periodic IX column regeneration. All other discharges were in full compliance with limits specified in the Siemens State Waste Discharge Permit (Permit No. ST3919).

Waste discharge records are maintained by Siemens and are available for review at your convenience.

Very truly yours, L. J. Maas, Manager Regulatory Compliance LJM/pg cc:

S. R. Arlt - Water & Waste Utilities Director, City of Richland M. L. St. Martin - City of Richland L. J. Callan - Administrator, NRC Region IV C. A. Hooker - NRC Region IV, WCFO Siemens Power Corporation 1

Nuclear Division 2101 Horn Rapids Road Tel: (509) 375-8100 Engineenng & Manufactunng PO. Box 130 rex: 1509) 375-8402

[

Richland WA 993524130 9610080151 960913

{DR ADOCK0700g7

/g-gg

?

s' SIEMENS POWER CORPORATION Waste Discharge Permit No. ST3919 i

Report No.:

08-96 Report Period:

August 1.1996 through August 31.1996

)

1 SPC-WASTE EFFLUENTSTATION

..$ P M O M s W 4W 7" WslVAser5ge:'

sDAllh Madimurrh t

Y,. $h @ MFny" Mf"'S$ iMT(Limit)MD," Q(Lirhit)b,;E Flow Volume (gal) 267,067 313,136 (400,000)

(500,000)

NH as N (Ib) 47 212 4

(80)

(125)

NO as N (Ib) 517 875 3

(750)

(875)

Fluoride as F (Ib) 1,426 2,370 (2,500)

(3,150)

Total Suspended Solids (mg/l) 23 31 (300)

(600) pH Average: 8.1 Minimum:

7.8

(>6.0)

(>6.0)

.The dai!y maximum limit for NH as N was exceeded on August 2, 3 and 4. The cause was 3

related to the periodic regeneration of the uranium ion exchange (IX) column. The solution used to elute the column contains ammonia and, due to a valving problem, backflowed into Lagoon SA via waste sewering piping located between Lagoon SA and the IX column. When IX regeneration was completed and waste sewering from Lagoon SA resumed, this ammonia solution was discharged to the sewer. A manual block valve will be installed to supplement the existing solenoid valve to prevent a recurrence of this incident.