Application for Rev to Certificate of Compliance 9073 for Model OH-142,incorporating Responses to NRC 850415 Comments. Rev 8 to OH-142 SAR Encl
ML20128F564
Person / Time
Site: 07109073
Issue date: 05/06/1985
From: Temus C
NUCLEAR PACKAGING, INC.
To: Macdonald C
NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS)
Shared Package
ML20128F537 List:
References
25223, 3775, NUDOCS 8505290673
Download: ML20128F564 (2)


Text

- _ _ _

ygg s

NRKLF/lR w'WOh!Ei May 6, 1985 Files OH-142 Ref:

3775-Mr.' Charles E. MacDonald, Chief Transportation certification Branch U. S. Nuclear Regulatory Commission M

Washington, DC 20555

-}p 39 DSS

Dear Mr. MacDonald:

Enclosed please find 8 copies of the consolidated version of Revision 8 of the OH-142 Safety Analysis. Report, Certificate of Compliance No. 9073.

The changes made for Revision 8 were done in response to NRC comments dated April 15, 1985, and'a brief esplanation of how the comments were incorporated is included as Attachment I.of this letter.

A. consolidation of all previous submittals made by Nuclear Packaging has been made to eliminate confusion caused by some of the pages in previous submittals being printed on both sides of the paper. This has led to obsolete data having been retained in NRC files despite administrative controls to delete the informa-tion.

We believe consolidation of the report to be the simplest means of insuring only current data is referenced.

Because this submittal consolidates only the current applicable data from all previous submittals, previous submittals should be considered obsolete in their entirety.

This consolidation revision, including revised drawings, has been copyrighted.

This entire submittal contains proprietary informa-tion per the notice included on the fly leaf of this report.

We are aware of your requirements to place this submittal in the Public Documents Room.

This may be done with our permission; however, this permission should not be construed as-a waiver of or in any way prejudicial to our lawful proprietary rights to this material..It is done only to facilitate the issuance of a-

. Certificate of' Compliance.

Photostatic copies of this copyrighted material may be made by MRC review personnel for convenience and for. record purposes within the Commission's files; however, permission to copy the material is espressly denied to persons other than Commission personnel or for any other reason.

Copies of the material may not be released by the commission except to the Public Documents Room.

o 9

6P:0N 6-M Gs, c

cocnna tt$NRO fg C

7

_..~.v _ _ _ _ _ s e m n,

+

m May 6, 1985 Mr. Charles E. MacDonald, Chief U. S. Nuclear Regulatory Commission Page 2 Thank you for your timely response to our application for minor amendment.

In light of our current contractual obligations, it is very much appreciated.

If you have any questions, please do not hesitate to call either myself or Stephen Goetsch.

Again, thank you very much.

Very.truly yours, NUCLEAR PACKAGING, INC.

[

l/

Charles J. Temus Technical Director

Enclosures:

As stated above.

l

MmPaa OH-142 SAR Rev. 8, 5/85 ATTACHMENT I RESPONSES 2n st_Q C080ENTS DATED APRIL 15,1985 Drawinas l

1 The drawings should specify the member of bolts required for each closure arrangement and the toaque requirement should also be noted.

The drawings have been modified to note these items.

2.

Given that the laside diameter, shell thicknesses, and shielding thieksess are the same for all models, the essk body diameter (76 in.) should be the same on all drawings lastading page 0-4e.

The drawings in Appendix 1.10 as well as the sketches in Section 0 have been modified to show the configurations currently being built. Apparent discrepancies in the cask body diameter as shown on the drawings arise f rom the previous outer shell thickness requirement of 1.125 in, when ASTM A36 is used.

When ASTN A516 Gr. 70 is used, the outer shell is taken as 1.0 in. thick. Since no new casks are being built with the A36 material, all drawings have been nado consistent with the A516 material.

Note 13 on Drawing AL-20-203 allows the one unit f abricated to the A36 specification to continue in compilance to this drawing and, by refer-ence, to Certificate of Compliance 9073.

3.

The dravisse members given at the top of page 0-4b do not agree with the drawing members given la the title bleek of the dravlag in that the letter 'D' is not part of the dravlag member as shown la the drawing title bleek.

The drawing numbers at the top of page 0-4b have been modified to agree with the title block drawing number.

l 4.

Note 9 on Drawing No. Y-20-201D makes referesse to magnette particle esaminattom per Asus Code, Seetion V, Article 2.

The reference should be made to Article 7.

NaPas OH-142 SAR Rev. 8, 5/85 The drawing has been changed to reference Article 7.

5.

The drawings should provide, either by note or detail, the marking and identification requirements of 10 CFR 71.35(e).

A note requiring the marking and identification described in 10 CFR 71.85(c) has been added to each of the drawings.

6.

The drawings shosle speelfy, either by note or by detail, the appliestion of a temperproof feature to satisfy the requirements of 10 CFR 71.43(b).

A note requiring tamper-indicating devices has been added to each of the drawings.

f_d Onoratina Procedures 1

1.

Amy movement of the essk from the vehicle to a loading area mast be done prior to removal of the closure lid. As lastruction relating to sneh handling reestrements should be made prior to Stop 6.1.1.

The cask cannot be moved at all without the presence of the closure lid.

A note has been added prior to Step 6.1.1 stating that the instructions for loading the cask assume that the cask has been placed in the loading area and is ready to be loaded.

The instructions have been expanded to include botton-loading procedures, as well.

j 2.

Step 6.1.1 should be expanded to require as laspestlos of ensk slosure devise with eriteria for replacement.

1 Notes requiring inspection of closure devices prior to loading activities have been added throughout Section 6.1.

l 3.

Step 6.1.5 should be expanded to speelfy the torque requirement on the steente devlee (ratchet binders and studs and ants).

MmPas OH-142 SAR Rev. 8, 5/85 Torque requirements have been written into the procedures.

4.

A step should be inserted between 6.1.5 and 6.1.6 requiring a radiation survey of the package prior to release for shipment to assure complianos with 10 CFR 71.47.

The package should also be inspected for surface contamination to assare sempliance with 10 CFR 71.31(1).

Steps have been added to the procedure to explicitly require the radia-tion survey and surface contamination inspections required by 10 CFR 71.

5.

A step should be added requiring a leak test of all packages except those containing only low specifle activity material transported by exclusive use vehicle.

A step requiring a leak test on all shipments except those containing only low specific activity has been added to the procedure.

6.

The procedures for resolving and saloading the package should imelade a statement regarding eempliamee with the lustructions of 10 CFR 20.205.

A statement requiring compliance with the instructions of 10 CFR 20.205 has been added to the unloading procedure in Section 6.2.

1,1 Accentance Tests l

The seettom on asseptance testing is imeosplete in that it does not address the subjects of pressure testing whom required by 71.85(b) and shield intes-rity testing.

The acceptance testing section has been augmented to require the leak test described in 10 CFR 71 as well as shield integrity testing.

Shield integrity testing is described in Appendiz 7.3 of the report.

w NaFae 08-142 SAR Rev. 8, 5/85

=

L), Mainte===ce Proaram 1.

The reference to Seetion 6.1 in paragraph 7.2.2 seeds elarification. The referesse sited does not somtsin the information being referessed.

The reference has been changed to reference the drawings, as it should have.

2.

The malatenasse program should be spesifie regarding the items to be examlaed and the fregneasy of routine examinations and periodio testing. Also replacement parts must be in assordamse -wi'th the specification gives in the application. Using equivalent parts is not' acceptable.

The maintenance program has been enhanced to explicitly state inspection f requency and testing f requency. The use of'the word ' equivalent' has been eliminated in the maintenance program.

General no opposite side of pages 0-4,1-83, and 1-94 should be deleted by revislag the pages. The opposite side of the pages costala pages that have been super-seded.

New copies of the pages ' indicated have been included with this latest consolidated revision. These'new' copies are printed on only one side. He use of double sided printing will be avo' ded in the future.