l M

GPU Nuclear Corporation RU lN E

loo lnterpace Parkway Parsippany, New Jersey 07054-1149 (201)263-6500 TELEX 136-482 Writer's Direct Dial Number:

i June 28, 1985 5211-85-2121 Office of Nuclear Regulatory Commission Attn:

J. F. Stolz, Chief Operating Reactor Branch No. 4 U.S. Nuclear Regulatory Commission Washington, D. C.

20555

Dear Sir:

Three Mile Island Nuclear Station Unit 1 (TMI-1)

Operating License DPR-50 Docket No. 50-289 EQ - Incore Thermocouple Cables / Connectors As discussed in JIO-84-TI-6 Rev. 2, attached to GPUN letter dated March 25, 1985, GPUN sponsored a test of the incore thermocouple cables and connectors from March 17, 1985 to April 4, 1985. The test was actually conducted by Bailey Controls Quality Test Lab; irradiation was performed at Georgia Institute of Technclogy;'

and the steam and chemical spray test was performed at the Nuclear Engineering Lab of Ohio State University. Using Test Report No. QR-0141-000 Rev. B dated 6/12/85 as a basis, GPUN now considers the incore thermocouple cable and connectors fully qualified to the 00R Guidelines in accordance with 10CFR50.49. GPUN EQ File EQ-TI-139 documents the qualification and is available for review in the GPUN central file.

Ther'efore, JIO-84-TI-6.is no longer required and is cancelled.

cincerel,

W-

. F. Wils n Vice President Technical Functions Ir/2042f cc:

R. Conte J. Thoma 0507050371 050A2G DR ADOCK 0500 9

g l

0

,. = -

,7 GPU Nuclear Corporation is a iubsidiary of General PutAc Utilities Corporation h