g WMF CREEK NUCLEAR OPERATING CORPORATION f ortest 1. Rhodet Vge Presukmt thgirwering February 3, 1993 ET 93 0017 U. S. Nuclear Regulatory Commission ATTH:
Document Control Desk Mail Station P1-137 Washin, ton, D. C. 20555 e
References:
1)
Letter dated November 19, 1992, from W. D. Reckley, USNRC, to B. D. Withers, WCHOC 2)
Letter ET 92-0032 dated March 11, 1992 from F. T. Rhodes, WCNOC to the USNRC
Subject:
Docket No. 50-482:
Response to Request for Additional Information on the Reload Safety Evaluation Methodology for the Wolf Creek Generating Station Gentlemen This letter submits Wolf Creek Nuclear Operating Corporation's (WCNOC) response to a Request for Additional Information (RAI) provided in Reference 1.
The RAI concerns WCNOC's ' Reload Safety Evaluation Methodology for the Wolf Creek Generating Station' which was submitted in Reference 2.
At a site visit on November 13, 1992, WCN00 and Mr. W.
D.
Reckley, Project Manager, Nuclear Regulatory Commission (NRC) discussed the draft RAI and responses.
The Attachment provides WCNOC's formal response to the NRC questions provided in Reference 1.
As discussed in Reference 2,
it is again respectfully requested that the Attachment to this letter be regarded as proprietary information, in accordance with the provisions of 10 CFR 2.790, and be withheld from public disclosure on the grounds that it contains trade secrets and confidential commercial information.
The affidavit, which accompanied Reference 2, sets forth the basis by which this information should be withheld from public disclosure by the Commission and addressees.
080081 PO. Dox 411/ Burlington KS 66839 / Phone. (316) 304 B831
}
)
h IkO h hob 82 An twai en nunay Erns ver mcm P
)
!,q t+.
. o, ET 93-0017 t.:ge 2 of 2 If you have any questions concerning this matter. please contact me at (316) 364-8831 Ext. 4002 or Mr. Kevin J. Moles of my staff at Ext. 4565.
Very truly yours, (1. '/
HA V
a Forrest T. Rhodes Vice President Engineering FTR/jra Attachment cca A. T. Howell (NRC), w/a J. L. H11hoan (NRC), w/a-G. A. Pick (NRC). v/a W. D. Reckley (NRC). w/a