t 1
'9 D924 l
Distribution: w/ enc 1 CEWilliams CRilarotta Docket File i
NRC PDR RETtgMTO L
IE HQ L MachER Region II gg FCTC:CEW PMSS R/F 71-9094 JtE 2 4 W FCTC R/F Chem-Nuclear Systems, Inc.
ATTN: fis. Susan Kintner 220 Stoneridge Drive Columbia, SC 29210 Centlemen:
This refers to your application dated liay 1,1935, requesting renewal of Certificate of Compliance No. 9094 for the Model No. CNS 14-195-H packaging.
In connection with our review, we need the information identified in the enclosure to this letter.
The information requested should be submitted within 60 days from the date of this letter. The additional infomation requested by this letter should be submitted in the forn of revised pages.
If you have any questions regarding this matter, we would be pleased to meet with you and your staff.
Your submittal of flay 1,1985, transmitting your consolidated application for renewal is considered to satisfy the condition for timely renewal.
' Accordingly, Certificate of Compliance No. 9094, Rev. 8, will not expire until a final determination has been rade by the Comission.
Sincerely, g,h3e#aM OdrL o
Ch$
E. tiacDonald, Chief Transportation Certification Branch Division of Fuel Cycle and ttaterial Safety, HMSS
Enclosures:
As stated
&l0jDOCK073o9o94 0278 850624 C
,h v
l
.~...Qg/'FCTE dbFCTC C
~'
~
""~ ^""
_.u (MTTTTIidIIITm"C$irdEE5' lEEaEU5niii 7 755 U
5 UNk75
- m >
l unc ronu na no-e0) NRCM ONO OFFICIAL RECORD COPY
Chem-Nuclear Systens, Inc.
l'odel No. CNS 14-195-11 Packaae Docket No. 71-9094 24 Encl to ltr dtd:
Operatino Procedures 1.
The operational steps requiring a cask survey should be expanded to specify a radiation survey including a detemination of surface contamination to assure compliance with 10 CFR $971.47 and 71.87.
2.
Step 8 under 7.2 Loading Procedures for Liners requires the use of alignment marks to correctly position the secondary lid onto the primary lid. The packaging drawing should be revised to show the required alignnent parks.
It is noted that Section 3.0, Tests and l'aintenance, also discusses lid alignnent parks.
3.
Procedures for receiving and unloading the package should include a statenent regarding compliance with the requirements of 10 CFR 520.205.
Acceptance Tests The consolidated application should provide the following infomation if additional units of the CilS 14-195-H packaging are to be fabricated:
The application should contain a section on acceptance tests which discusses the tests and inspections that will be perfomed prior to first use of the packaging (10 CFP, 571.85). State the criteria for acceptance for each test and inspection as well as the action to be i
taken if noncoapliance is encountered. The tests and inspections should include but are not limited to the following areas:
Specify the method of nondestructive exanination and the acceptance o
criteria that will be used to detemine weld joint integrity. This infomation should also appear on the packaging drawings.
l l
o Shielding integrity test: Give a brief description of the nothod including specifically the grid size and the acceptance criteria.
Discuss the r:ethod to be used to detemine that the closure lid and o
gasket arrangenent will satisfy the requirenents of 10 CFR Part 71.