ML20128E036

From kanterella
Jump to navigation Jump to search
Forwards PNO-III-75-016 Re Cracked Fuel Pins in Spent Fuel Assemblies
Date released: 05/21/2020 Download: ML20128E036


PNO-III-75-016:on 740630,util Reported That Insp Conducted for 10 Spent 7x7 Fuel Assemblies Which Had Been Previously Identified as Fuel Leakers.Preliminary Results Indicate Longitudinal Cracks in Clad
ML20128E043
Person / Time
Site: Monticello 
Issue date: 07/01/1975
From: Choules N, Fiorelli G, Jordan E
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To:
References
Download: ML20128E043 (1)
Forwards PNO-III-75-016 Re Cracked Fuel Pins in Spent Fuel Assemblies
ML20128E032
Person / Time
Site: Monticello 
Issue date: 07/01/1975
From: Fiorelli G
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To: THORNBURG H D
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE)
References
Download: ML20128E032 (1)