_ - _ _ _ _ _ _ _ _ _ _ _ _ _ _

O-i i

DOCKET No: 50-263 DATEt AN 21974 i

LICENSEEt Northern States Power Company PACILITY: Monticello Nuclear Generating Station itINUTES OF MEETING WITil NORTHERN STATES POWER Col!PAhT (NSP) RLTRESENTATIVES IN BETilESDA, MARYLAND ON MARCH 22. 1974 - HONTICELLO PROMPT RELIEF TRIP (PRT) ELECTRICAL CONNECTIONS AND CONTAINNENT PENLTRATIONS 1

NSP and Directorate of Licensing representatives (see enclosed list for attendees) met to review the routing for all the PRT electrical.

I cabling, including containment penetrations, the new connections at relief valves, connections to the reactor protection system, and cabinets.

The purpcae of the meeting was to expedite the Licensing evaluation so that installation can proceed as scheduled.

A suitable illustration of the two solenoid valve arrangement at the i

relief valves was not available during the meeting. NSP coisaitted to provide a solenoid valve arrangement drawing and also, for similar reasons, to provide a list of electrical penetration categories with-system identities and some representative electrical loads.

\\%\\

James J. Shea i

Operating Reactors Branch #2 Directorate of Licensing l

Enclosure; List of Attendees cc w/enclosuret L. Heyer, NSP J. Callo AEC PDR R0 (3) j Local PDR ACRS (16) e4focket File J. C. Snell L Reading T. Ippolito RP/TR Assistant Directors D. Basdekas RP/TR Branch Chiefs R. W. Reid T. J. Carter R. M. Diggs J. M. Hendrie J. J. Shea R. Revan or rec a >

,, [,,,,..,,,,,

e v a n a a. >

E81 _h

.,,,,,,.W Mann 3/28g_

pff 74

.a...

Form AEC418 (Rev. 9 S)fAECM 0240 e.o f cas to e t ee s.

see sea 9212070430 740402 PDR ADOCK 0500 3

P

.i

LIST OF ATTENDEES,

}IEETING WITH NORTHERN STATES POWER COMPANY MARCil 22, 1974 Nar,e Affillation C. B. Ilogg Bechtel L. H. Frauenholz General Elcetric J. McCready General Electric

5. P. Crim General Electric W. J. Hill Northern States Power G.11. Neils Northern States Power J. C. Snell AEC - Licensing J. J. Shea AEC - Licensing T. Ippolito*

AEC - Licensing D. Basdekas AEC - Licensing R. W. Reid AEC - Licensing

  • Initial attendance only m

e