Amend 14 to License R-95,changing Allowable Ph Range of Secondary Coolant Water from 5.5-7.5 to 5.5-9
ML20128D300
Person / Time
Site: Rhode Island Atomic Energy Commission
Issue date: 05/20/1985
From: Thomas C
Office of Nuclear Reactor Regulation
To:
Shared Package
ML20128D284 List:
References
R-095-A-014, R-95-A-14, NUDOCS 8505280556
Download: ML20128D300 (4)


Text

ys**%q'o,,

[

UNITED STATES v

8y

-[ j NUCLEAR REGULATORY COMMISSION n

WASHINGTON, D. C. 20555 s,

,/

PHODE ISLAND ATOMIC Fi!ERGY C0f?!!SSION 00Cr?T NO. 50-1Q3 AMENP'ENT TO FACILITY OPERATIf:G LICENSE Amendrent No. 14 License No. R-95 1.

The Nuclear Pegulatory Commission (the Commission) has found that A.

The application for amendment to Facility 0ceratina License No. R-95, filed by the P.hode Island Atonic Erergy Commission (the licensee), dated April 24, 1985, comolies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act), and the Commission's regulatiore as set forth in 10 CFR Chapter I; B.

The facility vill operate in confornity with the amended license, the provisions of the Act, and the rules and regulations of the Conmission; C.

There is reasonable assurance (1) that the activities authorized by this amendment can be conducted without endannering the health and-safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations; D.

The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; E.

The issuance of this amendment is in~accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied; and F.

Publication of notice of this amendment is not required since it does not involve a sinnificant hazards consideration nor amendment of a license of the type described in 10 CFR Section 2.106(a)(2).

8505280556 850520 PDR ADOCK 05000193 P

PDR L.

r 2-2.

'Accordingly, the license is emended by changes to the technical specifications as indicated in the attachment to this license amendment, and paragraph 3(b) of Facility Operating License No. R-95 is hereby amended to read as follows:

(b) Technical Scacifications The technical specifications contained in Appendix A, as revised through Amendment No.14, are hereby incorporated.in the license. The licensee shall operate the facility in accordance with the. technical specifications.-

3.

This license. amendment is effective on its date of issuance.

FOR THE NUCLEAR REGULATORY COMMISSION Cac.ie o. o w :-

Cecil 0. Thomas, Chief Standardization and Special Pro.iects Branch Division of-Licensing Attachnent:

Appendix A Technical Scecification Changes DATE OF' ISSUANCE: May 20, 1985 k..

w:

i FTACHEVENT TO LICENSE AMENDMENT NO.~ 14 TACILITY LICEf!SE t!O. R-95

' DOCKET N0'. 50-193 Revised Aopendix A-Technical Specifications are as follows:

~ Denove Pace ~

Add Paae 26 26 LThe change.on the revised page is identified by a maroinal line.

(

9 O

B

e

- ?6 -

pH 5.5 to 7.5 conductivity 2)kmho/cm (6) The radioactive materials contained in the pool water and in the primary coolant water shall be such that the radiation level one neter above the surface of the pool shall be less than 10 mrem /hr.

(7) During the forced circulation mode of operation, the primary coolant flow rate shall not be less than 1200 gpm.. During

. determinations of reactor power by coolant heat balances, the coolant flow rate may be reduced to 600 gpm providing all other aspects of these Technical Specifications are met.

d.

Secondary Coolina System (1) The secondary coolant shall be sampled at a minirum frequency of once per. week and the samples analyzed for pH in accordance with written procedures.

Corrective action shall be taken to avoid exceeding the pH limit given below:

pH 5.5 to 9 (2) The concentration o# radionuclides in the-secondary water shall be determined at least once each day the reactor ocerates usino forced convection cooling.

The concentration shall be determined at least once per week when not being operated using forced convection cooling.

(3)

If the radioactive materials contained in the secondary coolant

~

exceed a radionuclide concentration in excess of the values in 10 CFR 20, Appendix B, Table I, Column II, above background, the reactor shall be shutdown and the condition corrected before operation using the secondary cooling system resumes.

(4) The secondary coolant' system shall be placed in operation as required during power operation utilizing forced convection in order to maintain a primary coolant core octlet tenDerature of 125"F or below.

e.

Reactor Core and Control Elements (1) The reactor shall not contain in excess of 35 fuel elements.

There shall be a minimum of four operable control elements.

Amendment No. 14 k'-

a