581 p TED EoY E E.d r/ M d[>

.y LONG ISLAND LIGHTING COM PANY SHOREHAM NUCLEAR POWER STATION ROM e y@)hER, N.Y.11792 p.o. sox sie. NORTH COUNT Direct Dial Number Y.:Ei April 15, 1985 lhR85-4157 N

0 Robert Perlis, Esq.

~

U. S. Nuclear Regulatory Commission 7735 Old Georgetown Rd.(Mailroom)

~

i m

Bethesda, Md.

20814 32 N

Dear Bob:

b Enclosed please find the following documents as listed below which were issued by the TDI Owners Group for the Shoreham specific DROR report:

(1)

Revision 1 to the DR/QR Report (2)

Component 03-315C Revalidation Checklist pages B5 of 12 through B12 of 12 (3)

Errata Sheets for Revision 1 to the DROR Report The bulk of the enclosed revisions to the DROR report reflects editorial comments received by the Owners Group following the initial issue of the Shoreham specific report.

Additional changes to the DRQR report include revisions required as a result of l

modifications to certain Phase I component reports already issued and are in agreement with testimony presented before the ASLB in hearings on the TDI engines.

Should you have any questions concerning the enclosed, please do not hesitate to contact me.

Very truly yours

gMz, og Bruce E.

rmano

/

Nuclear perations Support Department i

i BEG /klk l

Enclosures l

8505280464 850415 PDR ADOCK 05000322 G

PDR ec.sess.:

cc:

w/ enclosures Alan.R. Dynner, Esq.

Mr. T. Ellis, III Kirkpatrick, Lockhart, Hill, Hunton & Williams Chritopher & Phillips 707 East Main Street 8th Floor P.O. Box 1535 1900 M Street Richmond, VA 23212 Washington, D.C.

20555 Fabian G. Palamino, Esq.

Special Counsel to the Lawrence Brenner, Esq.

Governor Administrative Judge Executive Chamber, Room 229 Atomic Safety and Licensing State Capitol Board Panel Albany, NY 12224 U.S. Nuclear Regulatory Commission MHB Technical Associates Washington, D.C.

20555 1723 Hamilton Avenue Suite K San Jose, CA 95125 Robert E. Smith, Esq.

Guggenheimer and Untermyer 80 Pine Street New York NY 10005 cc:

w/o enclosures Dr. Peter A. Morris Dr. George A. Ferguson Administrative Judge Administrative Judge Atomic Safety & Licensing Atomic Safety & Licensing Board Panel Board Panel U. S. Nuclear Regulatory Howard Univeristy Commission 2300 6th Street, N.W.

Washington, D.C.

20555 Washington, D.C.

20059 Secretary of the Commission Atomic Safety and Licensing U.

S. Nuclear Regulatory Appeal Board Panel Commission U. S. Nuclear Regulatory Washington, D.C.

20555 Commission Washington, D.C.

20555 Atomic Safety & Licensing Board Panel Nuclear Regulatory Commission Washington, D.C.

20555 Mr. Marc Goldsmith Martin Bradley Ashare, Esq.

Energy Research Group Attn: Patricia A. Dempsey, Esq 4001 Totten Pond Road County Attorney Waltham, MA 02154 Suffolk County Department of Law Mr. Jay Dunkleberger Hauppauge, NY 11787 New York State Energy Office Agency Building 2 Empire State Plaza Albany, NY 12223 t

-r- - -

cc:

w/o enclosure Steph'en B. Latham, Esq.

Ralph shapiro, Esq.

Twomey, Latham & Shea 33 West Second Street Cammer and Shapiro, P.C.

9 East 40th Street j

P.O. Box'398 New York, NY 10016 Riverhead, NY 11901 James Dougherty, Esq.

Howard L. Blau 3045 Porter Street 217 Newbridge Road Washington, D.C.

20008 Hicksville, NY 11801 Jonathan D. Feinberg, Esq.

New York State Department of Public Service

.Three Empire State Plaza Albany, NY 12223 O

m 9

0

~~

~