| Person / Time | |
|---|---|
| Site: | Palisades, Big Rock Point File:Consumers Energy icon.png |
| Issue date: | 12/13/1988 |
| From: | Weil C NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III) |
| To: | Brady R Office of Nuclear Reactor Regulation |
| Shared Package | |
| ML20128C560 | List: |
| References | |
| FOIA-92-231 NUDOCS 9302040077 | |
| Download: ML20128C633 (1) | |
Text
- _ _ _ _ - _.
>$280p UNITEo STATES
,4(
o,,
NUCLEAR REGULATORY COMMISSION j;. - },7 jk '
[
e(
Q RE GtON lli
[f E
i
%g 799 RC05EvtLT moAD g [ L'Ib.
?,
CLEN ELLYN, lLLINOel 60137
+
/
....e
,4 DEC 131988 IY
' M, / )
MEM3RANDUM FOR: Ricnard C. Brady, Allegation Hanager, Office of Nuclear Reactor Regulation FROM:
Charles H. Weil, Investigation and Compliance Specialist, Region III
SUBJECT:
SUBSTITUTION OF GENUINE PARTS IN KASONEILAN VALVES SUPPLIED BY S-C CONTROLS TO VARIOUS NUCLEAR P0'm'ER PLANTS INCLUDING BIG ROCK POINT AND PALISADES (50-155; 50-255)
(AMSNO.NRR-88-A-0048)
/
A{m,,,
g g b een (2m?"
,,v.
~
The Consumers Power Company recently filed a report with the NRC under the requirements of 10 CFR 21. The essence of the report was that genuine parts for Masoneilan valves were substituted by S-C Controls (Sample-Webtrol, CVS Inc, and Cor-Vai were other companies mentioned too) for valves supplied to the Big Rock Point and Palisades plants. Region III understands the Office of Nuclear Reactor Regulation's Vendor Inspection Branch has referred the matter to the Office of Investigations and 01:RIV has opened an investigation.
Enclosed for your information/ action is a copy of a memorandum pertaining to the 10 CFR 21 report and a subsequent meeting between Region III, Consumers Power Company, and several vendors of the Consumers Power Company.
Please inform Region III of any subsequent developments in this matte.
J/
Charles H. Weil Investigation and Compliance Specialist
Enclosure:
Memo dtd 11/23/88, W. (.. Axelson to W. Beach cc w/ enclosure:
RAO:RIII DRP:RIII DRS:RIII OI:RIII W. L. Axelson Allegation Coordinators RI, RII, RIV, RV Enclosure Contains EXEMPT FROM DISCLOSURE INFORRATIOk Upon Separation This Page is Decontrolled y
'CORTE92-231 PDR