ML20128B636

From kanterella
Jump to navigation Jump to search
Responds to NRC Bulletin 90-001,Supplement 1, Loss of Fill Oil in Transmitters Manufactured by Rosemount
ML20128B636
Person / Time
Site: Big Rock Point File:Consumers Energy icon.png
Issue date: 01/26/1993
From: Beckman W
CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.)
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
IEB-90-001, IEB-90-1, NUDOCS 9302030118
Download: ML20128B636 (1)


Text

_.

f f

Consumers s )

William L Beckman g;*h 1%nt Manager A

POWERING MICHIGAN'S PROGRESS Dig Rock Point Nuclear Plant,10263 US-31 North. Charlevoix, MI 49720 January 26, 1993 Nuclear Regulatory Commission Document Control Desk Washington, DC 20555 DOCKET 50-155 - LICENSE OPR BIG ROCK POINT PLANT -

REVISED RESPONSE TO NRC BULLETIN 90-01, SUPPLEMENT 1, LOSS OF FILL-Oll IN TRANSMITTERS MANUFACTURED BY ROSEMOUNT By letter dated January 8, 1993, Consumers Power Company submitted our response to NRC Bulletin 90-01, Supplement 1 (Loss of Fill-011 in Transmitters Manufactured by Rosemount).

In the Supplement response, a commitment was made to return spare transmitter (serial #377215) to Rosemount for module replacement before the end of 1993.

Further review of our records shows that this transmitter along with another Model 1153 transmitter used in a low pressure application (#383159) were returned to Rosemount in June of 1991.

These transmitters were sent back to Big Rock Point in August 1991 with module replacement completed and are now in stock as spares. This action was initiated by the former I&C Supervisor just prior to his retirement.

With confirmation of this action, all actions requested by Bulletin 90-01 for Big Rock Point are considered complete.

W

/

William L Beckman Plant Manager CC: Administrator, Region 111, USNRC NRC Resident Inspector - Big Rock Point f'GY 0200G4 0

9302030118 930126 PDR ADOCK 05000155 G

PDR A CAG ENERGYCOMPANY

_ _ - _ - _ _ _ _ _ _ _ _ _ _ _.