Text
~
r - -
["
l Cornell University bg# Q C
Ithaca, New York 14853 Nuclear Science and Engineering Program Ward Laboratory
. Director Office of Inspection and Enforcement U.S. Nuclear Regulatory Commission
' Region 1, 631 Park Avenue-King of Prussia, Pennsylvania 19406 Gentlemen:
Reference:
License No. R-80, Docket No. 50-157 License No. R-89, Docket No. 50-97 The purpose of this letter is to satisfy the requirements of Section 50.59 of 10CFR,'Part 50, in respect to activities carried out on the Cornell TRIGA reactor (facility license No. R-80) and the Cornell Zero Power Reactor-(facility license _No. R-89) during the period beginning July 1, 1982 and ending June 30, 1983.
TRIGA - License No. R-80 1.
Operating Experience During the period ' reported herein the TRIGA reactor was used primarily for the purpose of teaching and research and to a small extent, instrument _ test and calibration.
Teaching programs included, 1) control rod calibration, 2) use of a low intensity neutron beam for a nuclear measurement laboratory course, 3) introduction to neutron' activation analysis, and 4) demonstration of reactor operation during steady-state and pulsed modes.
Research programs included.I 1) t' race. analysis 'by neutron acti-vation analysis, and.2) use of a' neutron beam for the investigation-of fissioning isomers.
Instrument test and calibration included performance measure-ments of neutron sensitive detectors, utilizing the central thimble, thermal column, and the annular space in the reflector.
2.
Changes in Facility Design
-None 3.
Changes in Procedures
'None ffO gs24g0lSh7
'[#
a i
v a _
-' 0
'i
' Director..
Office of-' Inspection
.and' Enforcement
,4.
.Surve111ance' Tests'and Inspections A11 parameters and systems. undergoing surveillance tests and inspections-were determined to be within the specified limits.
5.
Power Generation 56.0 megawatt hours 6.-
Emergency Shutdowns None 7.
Unintentional Scrams
'None 8.
z Major Maintenance
-None 9... Radioactive Waste Release f
- 1) 30 pCi of liquid waste (gross activity)
-2) 264 mci of-Argon-41 as gaseous waste
- 10. ^ Personnel Exposure
-No significant radiation exposure'to personnel was experienced.
Zero Power Reactor 1..
Operating Experience
- 1). Familiarization with reactor design and facility operational s
rules and procedures..
2). Hands-on experience during start-up and operation of the facility,up to 1 watt under the supervision of a licensed operator.
3); Control rod calibration by differential period measurement.
u4) '. Reactivity _ measurements of peripheral fuel rods.
15)' Measurement of radial and axial flux distribution in core
.and reflector by activating a string of gold foils.
Other utilization involved the Operating Requalification Program
^
for two faculty members and one staff member.
2.-
Changes'in Facility Design i.;.
None 3.
Changes-in Procedures
^-None
.(..
e-
. Director Office of Inspection and Enforcement 4.
Surveillance Tests and Inspections All parameters and systems undergoing surveillance tests and
' inspections were determined to be within the specified limits.
5.
Power Generation-Power generation was'approximately 35 watt hours which included 15 start-ups.
6.
Emergency Shutdowns None 7.
Unintentional Scrams None 18. Major Maintenance None 9.
Radioactive Waste Release No measureable amount.
10.
Personnel Exposure No significant radiation exposure to personnel was experienced.
If any additional information is required concerning this report, please don't hesitate to contact this office.
Sincerely yours, h4 Howard C. Aderhold Reactor Supervisor HCA:jr
_ cc: Director, Inspection and Enforcement U.S. Nuclear Regulatory Commission Washington, D. C. 20555 i
a r
--,,,-a v-m v
r, w