l l

l APPENDIX A NOTICE OF VIOLATION Portland General Electric Company Docket No. 50-344 121 S. W. Salmon Street License No. NPF-1 Portland, Oregon 97204 As a result of inspections conducted January 7-11 and May 13-17, 1985, and in accordance with the NRC Enforcement Policy, 10 CFR 2, Appendix C, the following violation was identified.

l l

10 CFR 20.201 Surveys, requires, in part, that "(b) Each licensee shall make or cause to be made such surveys as (1) may be necessary to comply with the regulations in this part, and (2) are reasonable under the circumstances to evaluate the extent of radiation hazards that may be present."

Contrary to the above requirement, the licensee failed to evaluate the i

extremity exposures due to nonpenetrating radiation following the steam generator insert handling occurrence of August 16, 1984.

The licensee had identified the failure to provide extremity exposure monitoring devices and in response had performed an evaluatior af the extremity exposure due to penetrating radiation. The failure to evaluate extremity exposure due to nonpenetrating radiation was identified by the NRC. The licensees subsequent evaluation established a maximum extremity exposure of 8.759 rem.

This is a Severity Level IV Violation (Supplement IV) l Pursuant to the provisions of 10 CFR 2.201, Portland General Electric Company is hereby required to submit to this office within thirty days of the date of i

l this Notice, a written statement or explanation in reply, including:

the corrective steps which will be taken to avoid further violations. Considera-tion may be given to extending your response time for good cause shown.

1 JUN 131985 g gg, l

Dated

. A. Scarano, Director Division of Radiation Safety and Safeguards l

8507020578 850613 PDR ADOCK 05000344 0

PDR l

l l

l

- -