ML20127P836

From kanterella
Jump to navigation Jump to search
Forwards Draft Rept to AEC Regulatory Staff Adequacy of Structural Criteria for Monticello Nuclear Generating Plant Unit 1
ML20127P836
Person / Time
Site: Monticello 
Issue date: 02/17/1967
From: Newmark N
ILLINOIS, UNIV. OF, URBANA, IL
To: Case E
US ATOMIC ENERGY COMMISSION (AEC)
Shared Package
ML20127P840 List:
References
CON-AT(49-5)-2667 NUDOCS 9212030136
Download: ML20127P836 (1)


Text

__. _ _ _ _ _ _ _ _

  • .)

N'ATHAN M.NEWMARK lll TALBOT LABORATORY. URSANA. ILt.lNOIS vf a

l CONSULTING ENGtNEERING SERWCES t

[

17 ftbruary 1907

)

1 P'. r. Edson C. Case l

Assistant Director

.i Division of Reactor Licensing U.S. Atomic Energy Commission Washington, D.C. 20545

[

'b Y,

Re.

Cont rac t No. AT (4 9-5)-7007.

/

Monticcilo unit 1 (Doc.ct No. 50-203)

Northe.n States Power Company i

l

Dear Mr. Case:

1 Ve are f orwarding berewi th two copies of the draf t report entitled i

" Adequacy of the S t ruc tural _ Cri teria f or the Mont icello Nuc lear Genera ting i

Plant Unit 1," prcpored by Dr. W.

J. Itall and myself.

In our report we have l

colled attention to several i terrs which s t ill need c larlf ica t ion, and we shall be pleas (d to discuss.these with your staff as appropriate.

Sincerely yours, NNh%d N. M.

Newmark.

bd

. Enclosures d) g cc:

W. J. Hall e

A\\

.-q4}(i

/

/

411; 4 i

1

'9212030136 670217' i

PDR.- ADOCK 0500 3

A t; ;* ;).

a

.. ~

....- c.

.