Forwards Rev 1 to Environ Equipment Summary Sheets (Eess) Index. Rev Supersedes Eess Index Submitted on 850625.EESS 153 & 155 & Attachment to Eess 73 Also Encl for Incorporation Into 850625 Submittal
ML20127P095
Person / Time
Site: Hope Creek 
Issue date: 06/28/1985
From: Mittl R
Public Service Enterprise Group
To: Butler W
Office of Nuclear Reactor Regulation
References
NUDOCS 8507020306
Download: ML20127P095 (10)


Text

o O

O I)#S G Cornpany Puthc Service Ecctnc and Gas 80 Park Plaza, Newark, NJ 07101/ 201430 8217 MAILING ADDRESS / P.O. Box 570, Newark, NJ 07101 Robert L. Mitti General Manager Nuclear Assurance and Regulation June 28, 1985 Director of Nuclear Reactor Regulation U.S.

Nuclear Regulatory Commission 7920 Norfolk Avenue Bethesda, MD 20814 Attention:

Mr. Walter Butler, Chief Licensing Branch 2 Division of Licensing Gentlemen:

ENVIRONMENTAL EQUIPMEN'T QUALIFICATION HOPE CREEK GENERATING STATION DOCKET NO. 50-354 Attached please find one copy of Revision 1 of the Environ-mental Equipment Summary Sheets (EESS) Index.

This super-cedes the EESS index previously transmitted on June 25, 1985 (R.

L. Mittl, PSE&G to W.

Butler, NRC, le t te r ).

In addi-tion, also attached are EESS Nos. 153 and 155 and the attachment to EESS No. 73.

These pages are to be incorpo-rated into the EESS set transmitted on June 25, 1985.

Should you have any questions in this regard, please contact us.

Very truly yours, e

Wp/ /

C D.

H. W.agner USNRC Licensing Project Manager A.

R.

Blough USNRC Senior Resident Inspector H. Garg USNRC EQ Branch 8507020306 850628 dD PDR ADOCK 05000354 g

PDR M. Yost A

EG&G Idaho Inc.

The Energy People 954312 (4W 7 83

HOPE CREEK GENERATING STATION EESS INDEX ggg/, j (N to: N heeto not complcted)

(o[z?/65 I,Y REF.

No.

EESS No.

DESCRIPTION ponents STATUS 1

Ell 2-MOT-001 Westinghouse SACS Pump Motor 4

2 Ell 8-MCC-001 Eaton/ Cutler Hammer 480 Vac MCC 4

Complete 3

E121-SWGR-001 General Electric DC MCC 2

Complete 4

E129-CABL-001 Okonite SKV Power Cable 5

Complete 5

E135-PEN-001 Westinghouse Low Voltage Power and Control Electrical Penetration 34 Complete 6

E135-PEN-002 Westinghouse Madium Voltage Electrical Penetration 6

Complete 7

E157-CABL-001 okonite 600V Copper Control Cable 7

Complete 8

E158-CABL-001 okonite 600V Copper Power Cable 27 Complete 9

E170-CABL-001 Brand-Rex Co-Axial, Twin Axial, Tri-Axial Cables 7

Complete 10 E170A-CABL-001 Rockbestos Co-Axial and Twin Axial Cable 4

Complete 11 E170A-CABL-002 Rockbestos Type SIS Switchboard Wire 4

Complete 12 E170A-CABL-003 Rockbestos Multiconductor Cable 3

Complete 13 E171-CABL-001 Eaton 600V Shielded Instrument Cable 43 Complete 14 F35373-Wire TER-001 Thomas and Betts Wire Terminal 31 Complete 15 F35373-TWRAP-002 Thomas and Betts Tie Wraps 4

Complete 16 F37917-TFB-001 Buchannan Terminal and Fuse Block

-17 Complete 17 F43511-COND-001 Annaconda Flexible Conduit (NWC) 12 Complete 18 F43511-COND-002 Annaconda Flexible Conduit (NPW) 3 Complete 19 F43620-HVT-001 RavChem High Voltage Terminal Kit 1

Complete 20 F47888-MCON-001 RayChem N-MCK Motor Connection Kit 1

Complete 21 F48479-SEAL-001 RayChem Cable End Sealing Kit 2

Complete 22 F48561-TINS-001 Raychem Thermofit Insulation 1

Complete 23 F48561-SPL-002 RayChem WCSF-N Splice 1

Complate 24 F51216-SEAL-001 Conax Electrical Conductor Seal Assembly 1

Complete 25 J201-HS-001 Micro Switch Selector Switch 14 Complete 26 J201-AMP-002 AMP Wire WG 27 J201-TFB-003 Buchannan Terminal and Fuse Block 4

Complete 28 J301-T-001 Tobar Instrument Transmitter 20 Complete 29 J301-T-002 Tobar Instrument Transmitter 49 Complete 30 J359-VAR-001 Comsip Hydrogen & Oxygen Analyzer 49 Complete 31 J359-VAR-002 H /0 Heat Tracing Panel 2

2 2 32 RESERVED 33 RESERVED 34 RESERVED 35 RESERVED l

PAGE 2 No. of REF.

Com-No.

EESS No.

DESCRIPTION ponents STATUS 36 RESERVED 37 RESERVED 38 RESERVED 39 RESERVED 40 RESERVED 41 RESERVED 42 J483-LS-001 FCI Liquid Level Sensor 39 Complete 43 J556-TE-001 Weed Thermocouple 32 Completc 44 J601-SV-001 ASCO Solenoid Valve 5

Completc 45 J601-ZS-002 NAMCO Limit Switch 4

' Complete 46 J603-SV-001 valcor Solenoid valve 25 CompletG 47 J603-SV-002 Valcor Solenoid Valve 7

CompletG

.48 J605-SV-001 ASCO Solenoid Valve 2

CompletG 45 J605-HV-003 Rotork Valve Actuator 2

Complete 50 J800-XT-001 NDT Pre-amplifier 14 CompletG 51 J800-XE-002 NDT Accelerometer 14 Complett 52 M047A-MOT-001 Reliance 460V Motor 2

Complete 53 M047A-SEAL-002 Conax Seal Assembly 54 M047A-PNL-003 Power Panel 2

55 go47A-HR-004 Hydrogen Recombiner 2

56 MO47A-HTR-005 Heater 2

57 MO47A-FT-006 Flow Transmitter 4

58 MO47A-TE-007 Temperature Element 18 59 MO47A-HV-008 Control Valve 6

60 MO47A-FT-009 Pressure Transmitter 2

61 RESERVED 62 RESERVED 63 RESERVED 64 RESERVED 65 RESERVED 66 RESERVED 67 RESERVED 68 RESERVED 69 RESERVED 70 RESERVED 71 MO48-ME-009 Moisture Element 2

PAGE 3 No. ef EUU?.

Coct--

No.

EESS No.

DESCRIPTION ponents STATUS 72 M048-MOT-001 Westinghouse 2

Complete 73 M048-COMP-002 CVI Gas compressor and Control 2

Complete 74 M048-PS-003 ASCO Pressure Switch 14 Complete 75 M048-TS-004 ASCO Temperature Switch 12 Complete 76 M048-SV-0C3 Valcor Solenoid Valve 4

Complete 77 M048-CABL-006 Annaconda Panel Wire 2

Complete 78 M048-TFB-007 Buchannan Terminal and Fuse Block G

Complete 79 M048-REL-008 Amerace (Agastat) STR Time Delay Relay 2

Complete 80 M082-MOT-001 Westinghouse Motor 6

Complete 81 M711-MOT-001 Reliance Motor 24 Complete 82 83 M713-MOT-001 Westinghouse Motor 8

Complete 84 M713-ACT-002 ITT Electro-Hydraulic Actuator Complete 85 M717-SV-001 ASCO Solenoid valve 52 Complete 86 M717-ZS-002 NAMCO Limit Switch 50 Complete 87 M717-ACT-003 ITT Electro-Hydraulic Actuators 20 Complete 88 M729-SV-001 ASCO Solenoid valve 4

Complete 89 M723-ZS-002 NAMCO Limit Switch 4

Complete 90 M780-SV-001 ASCO Solenoid Valve 3

Complete 91 M780-TFB-003 Buchannan Terminal and Fuse Block 4

Complete 92 M780-FSL-004 DWYER Differential Pressure Switch 88 Complete 93 M780-TE-005 Weed RTD (Temperature Element) 60 Complete 94 M780-TS-006 PENN Temperature Switch 4

Complete 95 M780-TS-007 United Electric Temperature Controller 20 Complete 96 M780-HS-008 Micro Switch Selector Switch 48 Complete 97 M780-TRNS-009 Hevi-Duty Transformer 4-Complete 98 M790-REL-OlO Struthers Dunn Relay 78 99 M780-PT-Oll Tavis Differential Pressure Transmitter 20 100 M786-PNIr001 Air Filter System (Rem Con Pnl-Nutherm) 8 101 M786-HTR-002 Air Filter System (Nutherm Htr.)

29 102 M001-XV-001 Conax SLC Explosive Valve - Sll 2

Complete 103 M001-RE-002 General Electric Intermediate Range Monitor (IRM) Detector - C24 8

Complete 104 M001-MOT-003 G.E. SLC Motor - S10 2

Complete 105 M001-TE-004 PYCO Temperature Element - C03 91 Complete 106 M001-PT-005 Rosemount Pressure Transmitters - Cl3 15 Complete 107 M001-RE-006 G.E. Power Range Detectors (PhD's)-C50 43 Complete i

PAGE 4 No, cf REF.

Com-No.

EESS No.

DESCRTPTTOM pon'nto STATUS 108 M001-SV-007 Valcor Solenoid Valve, ATWS-A-1 2

Complete 109 M001-SV-008 Valcor Solenoid Valve, ATWS-A-1 8

Complete 110 M001-PT-009 Rosemount Pressure Transmitters, ATWS-C 4

Complete 111 M001-LS-010 Magnetrol Indicating Switch, ATWS-A-2 2

Complete 112 M001-LT-Oll Gould Differential Pressure Transmitters 4

Complete ATWS-A-2 113 M001-LT-012 Gould Differential Pressure Transmitters 4

Complete ATWS-B 114 M001-LT-013 Rosemount Differential Pressure Trans-4 Complete mitters, ATWS-C 115 M001-PT-014 Rosemount Pressure Transmitter ATWS-B 2

Complete 116 M001-MTR-015 G.E. ECCS Pump Motor -S01 8

Complete 117 M001-SV-016 Valcor Solenoid Valve (SDV) -S16A 2

Complete 118 M001-SV-017 Valcor Solenoid valve -S16B 2

Complete 119 M001-ZS-018 NAMCO Limit Switch - C26 8

Complete 120 M001-LT-019 Gould Level Transmitter - CO2 2

Complete 121 M001-RE-020 Insulated Detector - C05 4

Complete 122 M001-SV-021 Scram Solenoid Pilot Valve - S12 185 Complete 123 M001-HPCl-022 HPCI Turbine Assembly 13 Complete <

124 P301-SV-001 ASCO Solenoid Valve 31

Complete, 125 P301-ZS-002 NAMCO Limit Switch 31 Complete.

126 P301-HV-004 Limitorque D.C. Valve Actuator 6

Complete 127 P301-HV-005 Limitorque A.C. Motor Operator 89 Complete 128 129 130 131 P302-HV-002 Rotork Valve Actuator 1

Complete 132 P302-HV-003 Limitorque A.C. Motor Operator 34 Completei 133 P302-HV-004 Limitorque D.C. Valve Actuator 11 Complete 134 P302-ZS-005 NAMCO Limit Switch 9

Complete 135 136 137 P303A-9V-001 Rotork Valve Actuator 4

Complete 138 P303A-HV-002 Limitorque D.C. Valve Actuator 3

Complete 139 P303A-HV-003 Limitorque A.C.' Motor Operator 85 Complete 140 P303A-SV-004 ASCO Solenoid Valve 28 Complete 141 P303A-ZS-005 NAMCO Limit Switch 13 Complete 142 143

No. of REF.

Com-No.

EESS No.

DESCRIPTION ponents STATUS 144 P305-HV-002 Limitorque A.C. Motor Operator 35 CompletG 145 P305-SV-003 ASCO Solenoid Valves 13 Complete 146 P305-ZS-005 NAMCO Limit Switch 11 Complete 147 P305-HV-004 BIF/ Paul Monroe Hydraulic Actuator Assembly 4

Complete 148 149 150 M001-LS-023 Magnetrol Level Switches - Cll 2

Complete 151 M001-LS-024 Magnetrol Level Switches - Cll 4

Complete 152 M001- -025 G.E. Selector Switch, CR2940 - C12 2

l153 M001-CONN-026 LPRM/IRM Connectors - C23A/24A 55 Complete 154 M001-EAM-027 G.E. Voltage Pre-amplifier - C25 8

Complete

/)\\l155 M001-XMIT-028 Rosemount Pressure Transmitter ll53B-151 Complete C59 156 M001-

-029 NAMCO CRD Scram Discharge Volume Vent and Drain Valve Limit Switch - S14 4

157 M001-

-030 Terry RCIC Steam Turbine Assembly S08/SO9 2

158 M001-LS-031 NAMCO MSIV Limit Switch - S05B 8

Complete 159 M001-

-032 Safety Relief Valve - S20 19 160 M001-

-033 MSIV Actuator - S21 24 161 M001-

-034 Testible Check Valve - Air Operated TBD-S24 8

162 M001-

-035 Barksdale Pressure Switch - C09 4

163 J605-ZS-002 NAMCO Limit Switch 2

Complete 164 F59119-PG Gland Fitting 165 M780-MT-012 Nutherm Humidity Transmitter 22 166 M780-REL-013 Agastat Relay 59 167 168 J371-

-001 Radiation Monitoring System 2

169 J371-

-002 Radiation Monitoring System 2

170 J371-

-003 Radiation Monitoring System 3

171 J371-

-004 Radiation Monitoring System 2

172 M001-RE-037 SRM Detectors 4

173 M001-TE-038 Temperature Element (C22) 1 i

ARacll 6/21/85

ATTACHMENT TO EESS NO. M048-COMP-00 3 SH. 1 of 2 AT At ta ST/TWe 0.L.

M W /%piace r*. Sm akle many-(4)

(its)

(eV)

(T/5)

(Y1)

'3334 4 4 12 86.9 1.14 1 W 4.2 3.12 gene W96 W 9.6 WN.3 114f0.3 E001444 80 710.M 0.71 35/10 0.2 Replace CW1 Ases41y tury 5 years 106 700.3 125/10 4.R hplace klar try 15 Ises 18E/0.3 M

114.N.7 E001 4 4 4 80 710.M 0.95 W10 15.96 Replace Evry 15 Ines W10 1 W 0.3 n/N.7 2001 4 4 01 80 710.9 1.17 54/10 51.77 inne W10 P

1 W 0.3 M/3.7 N

A 20001 4 4 4 2

710.M 0.N W10

16. 5 hplace swy 15 Vers W10 1 W 0.3 WN.7 q

2001 4 d MIL M

710.M 0.95 M/10

15. 5 Replace Ewy 15 vers W10 1 W 0.3 n/N.7

,k 2001 4 G Mit 75 m.2 0M M/10 5.0 Replace Ewy 5 Vers W10 1M/ 0.3 m

n/5.7

~

i 20001 4 06 4 E

710.64 0.95 W10 15.96 Replace Ewy 15 Yeam W10 1M/0.3 0

5/3.7

{

20001 4 C H 6 5

52 0.5 M/10 5.5 Replace twy 5 Yess 94/10 y

1M/0.3 4

WN.7 k

f 20001 4 4 4 W

710.64 0.95 W10 15.96 Replace Eey 15 Yean W10 124/0.3 M/M.7

ATTACHENT TO EESS NO. M048-COMP-002 SH. 2 of 2 ProJoct Number 20001, Rov. O Pcgo 13 073 TABLE 3.1 EOUIPRENT SURRART.

FSM Tag Number i

Customer I.D. Number i

Description


l-----------------------


l--------------

E7 20001-01-01-01 l

C735-E6/C735-I Instrument Oss I

Compressor 1

I i

20001-02-01-01 1

5/15, C735-6002 i

A-B Relay I

i 20001-02-02-01 1

C735-6004 i

ATC Can Timer I

i 20001-02-03-01 1

9, C735-6002 I

ITE Gould Circuit i

1 Breaker I

i 20001-02-04-01 1

11, C735-6002 i

Micro Switch I

Pushbutton l

l i

20001-02-05-01 1

13 C735-6002 i

Micro Switch Pilot I

Light 1

I i

20001-02-05-02 i

N/A I

Micro Switch Pilot I

Light i

I i

20001-02-06-01 1

30, C735-6002 1

Panametric Dew I

Point Noter I

I 1

20001-02-06-02 1

31, C735-6002 I

Remote Noter I

i 20001-02-06-03 i

N/A I

Panametric Probe l.

I 20001-02-06-04 I

N/A l

Burndy Cable I

i I

GE Elapsed Time 20001-02-07-01 1

N/A I

Noter i

1 i

I 1

(

/

15 3 10 IPreff 15/A!13JtrION SJpetMtr SIErr Str. NO: M001-CONN-026 PRM CONNECTOR IE#. NO: 1 HOPE GEIK QNEIUtrING SrJtrION C23A/C24A OftrEs 6/2 F IberIIOcert 000MpfrJerICBI leT.leKE EQUIPfeff GJALIF.

OPEN mfPFIO8 PAftAPE.TEIE SPECIFIED GJA!EIIED SPECIFIED QUALIFIED IEDOD ITD6 MMCIN letMstS OPEIUtrIDc 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> 42 hours Ref.A Ref.A Test and None Adequate Margin demonstrated by anal {" sis (Ref.A.Pg.13 (1) SYStet NEUTRON Tg,g Pg.73 Pgs.129 Analysis

""d

" gI

""d

  • MONITORING Ref.A Ref.A Margin demonstrated by Analysis I,II 340'F(Max) 340'F(Max)

Po.116 Pos.13 & 129 Test None Adecuate (Ref.A. Pa.13 & App.F)

NO T N BER This is not a pressure MPL B11-D194 PlussJse 62 psig 56 psig Ref.A Test and None Not Req'd sensitive device.

(3) GM3eDir (PSIG)

(Max)

(Max)

Pgs.13 & 54 Analysis PRM (COAXIAL)

C ItELJurIvr.

1005 Ref.A Ref.A (4)ONNECTOR eineaJfactUltER IEJfGDITY (4)

(Steam) 1001 Pg.115 Pg.128 Test None Not req'd AMPHENOL FIIXBIIG/

N/A N/A N/A N/A N/A None Not req'd (5) tu n.10.

m CATALOG #901-199 3.14E7 RG 2.9E7RG(Test) Ref.A Ref.A Test Margin based on threshold ItAot>trIcne

((,)

FUNCrICDs (RA06) 4.2E6 RN 6E8RG (Thres)

Pgs.115 &

Pgs 41.13&52 Analysis None 5.7E8RG limit for RexoLite.

NOTE #1 4b rs 9 5 yrs 9

.A Ref A Test and Per10dic replacement 9 150*F Max 150'F Pg.87 and Analysis None Not req'd 5 yr. intervals gyg m gggg 114 Pg.157 al SPECIFIED N/A b) ACIUAL F

(8) (DCJtrICBI d

SPRAY N/A N/A N/A N/A N/A None Not req'd VESSEL AREA EL.120' (9) Aa0WE ME00 IBfEL DOCLMDirATION IElFElmeCE:

notes YES L ND A. GE N555 Report NEDC-30437 1.

Connector between PRM detector and cable.

IBook Number C23A/C24A) r R.G.1.97 Parameter. Category 2a.

s (10) SEISMICh!LY ' TESTED Rev. 1. Dated.5/30/85.

YEs L aEr. A le _ (Pg.67A)

(11) SNe#EI!MNCE 1g10D.

YES X BEF. A 30 ] (Pg.14)

j i

155 l i

SFF. ND: M0ul-XMIT-028 NRl!Reff EUAllMEFIGI S89tMtr !BIEEF UE#. ND: 1 ROSEMOUNT PRESSURE TRANSMITTER (11538-C59)

DRrE 6_/25/85 183E Otts asegurgsc stytrIO8 BOOK C59 Emft1Geert D003erturEGs IErtges3 GAALIF.

orans nearneprges paguggrges Sp KIFIED GAREEttED fEW'IFIED QUALIFIFD MHEB ITEBS MMCDI segums EQUIMeer ll7hr. D8E test extended Ref A Test and Nm 10 days Ref.A

.72 Analysis

)y analysis REf.A. Pg.72A opgggergsg; 100 days 110' days Appendix H (1) sygggge

.rgg 3gg.F (Max)

Ref.A Ref.A TgHEDSHEET g y {,y) 8 - 'ix J Paesc7 a can Test E

es 170+p i

(2) 148'F Ref.A Ref.A.Pg6.

3-30 min 73-8)x)hr Pg.42 657 1 661 Test None 70 psig 1

SEE ATTACHED SHEET PUESRJIE (Me 0-180 days J

(3) gyggger gygggy PT, LT & FT Ref.A Ref.A 100%

100% Steam App.J Pg.651 Test None Not req'd l

TRANSMITTERS segJurtyg j

(4) penserAc m aER imagottY (t)

M/A N/A A

N/A N/A None Not req'd 1

ROSEMOUNT INC.

g$g,qgggg,,g, 11538 SERIES 3.03E6 RG Z.44El RG Ref.A Ref.A 1.lE6 RB Pg.42 Pg.629 Test Mone 2.14E7 RG Note #1 gg (6) NEGI (IWWB)

SEE ATTACHED SHEET 40 yrs 17.8-20 yrs Ref.A Ref.A Test and 991'F P104*F App.J Pg.66 and Analysis None Not req'd (7) pensancy ag;Dg; Ref.8 c) !DECIFIED, See Jto,te Water Spray Ref.A Ref.A l

N/A App.J Pg.657 Test None Not req'd (3) m et SPithY SEE ATTACHED SHEET BUEES (9) ABOM plD0D tagL 0008tIBfWtFIGS IErt3EBICE:

1. Qualified Radiation level encompasses specified Gansna and VES.,1., IID A. GE Co Equipment Qualification Report Beta doses.

NEDC-30446, Dtd. 4/85 (10) EISEN 15WW B* GE Co. letter 55-85-006

2. Specific accuracy requirements *for each appifcation are being j

1 yas i ser. A Dated 5/14/85 addressed under a separate program.

BD _ (P.644)

I l

(11) EnemitJJesCE IEID.

I ygs j ser. A no li gy

~

'~