De b

HSRm NORTHE N

STATES POWER COMPANY MINN E A POL le. MtN N E GOTA 55404 October 9, 1975 f'd fi

",y' s

< x.,

f',

.\\

n g 4 g % r-

. gig 5"y\\

Office of Plans & Sche r

Division of Reactor L

.ig

J U S Nuc1 car Regulatory enission

}

j ppy

.g o.*

6A

$'hNNW y,

Washington, DC 20555

/

mutt

$z yg) linkil k,

~'

Attention: Mr S Chapman v f,A g

f Qb f*

l Gentiemen:

MONTICELLO NUCLEAR GENERATING PIR4T Docket No. 50-263 License No. DPR-22 Monthly Operating Data September 1975 Attached is the operating status information from the Monticello Nuclear Generating Plant for the month of September,1975 as requested in the February 19, 1974 letter from Mr L Manning Moatzing. Changes proposed in the September 12, 1974 letter from Mr D F Kn th have been incorporated into this report.

Very truly yours,

\\

- \\j IK \\ iT

'n

g. \\)

a 0

C 11 Neils General Superintendent of Nuclear Power Plant Operation GilN/JRT/ ts cc: J G Keppler Attachments PDR9212010495 750930 11920 R

ADOCK 05000263 PDR l

..._ J

~_

-2026 R.CVa 1 tlNIT tWlE m ff!CFLL NUCLTAll GEN!RATlhG PlAhT

[

InTE

.l_0/_4/75 Ntm COMPLET131 bY W 26La5T51~ E E Til -~

T61 OPERATING STATils i

1.

REFORTINC PIR10D:

000075.09_0.1.-

TO _24_0075 0930 GROSS LOURS IN Rl3ORTING PIRIOD: _.

q 720 2.

CURRFNFLY AlriliORI':ED P0hTR LIXEL MNt 1670

!!Ne-N!:r 538 3.

TOWIR LINEL TO h11101 RESTRICTLD (IF ANT): _LSee Item #4) 4.

RFASONS FOR RES1111CT10NS (IF AhT): Power Icyc1 was limited administrative 1y to minim:0 in plant radiation background and contamination IcVels.

'D0S CthUlATIVE FD:!DI YR-TO-DATE 10 InTE 5.

Il0URS REACTOR WAS CRITICAL 2 & 2_

5.376,7 28.783.3 6.

REACTOR RESERVli SillJrIOhN 110llRS 0

3.7 940.7 7.

IloilRS GINER\\ TOR ON-LINE 246.9 5,315.1 27,727;2 8.

UNIT RESEkVE Siltrl10L5 ll0URS 0

0 0

9.

GROSS tiler \\l\\L IOLIR Cl:IRATEle (?til)

_ 230,073.6

_7 344;504.0 48,779,481.8 a

10.

GROSS llECTRICAL POWIR Cl.NERATED 0111) 73,800

,2.,493,040 1,3_,943,800 11.

NiiT 110CfRICAL Poh1R Cl h1ETTLD (Bil) 67,448 2,376,286 13,317,920 12.

REACIOR AVAllABIL11Y 1 ACTCR (1) 35.3 %

82.1%

77.2%

13.

LINIT AVAllABI!1TY ITcl0R (2) 34.3 %

81.1% _

74.4%

14. UNIT CAPACITY 1:A C F. (3) 17.4 %

67.4%

66.4 %'

15.

FORCED OUTAGE RXlE (4)

4. 0_ _%

0.6%

11.7%

16 SillrITOhNS SGIEDULED TO BEGIN IN NENT 6 FO.Vn;S (STATE TYPE, fuTE, ANT) DURATION OF EACf1):

17.

IF-SIRJfD0hN AT liND OF REPORT PERIOD, ESTDMTED PATE OF STNGUP: November 9.1975 (1) RFACIDR AVAllABIL11Y FACTOR = Il0URS RFACTOR WAS CRITICAL

  • 100 CEOSS IiOIIR3~ITILITOIG1NG PERIOU-
  • 100 (2) UNIT AVAILABILI'lY FACTOR = Il0URS GEhTPATOR ON-LINE CRD4TTDI?iEnTRDWTTT Pi.RIOD
  • 100 (3) UNIT CAPACITY FACTCR = NET El.LC'lRICAL TOhliR GENERATLD NFI~IUDNS7TTIITFCiKI!iDE 1Y~11ITORTING PERT 0li (4) FORCED OlffAGE RATE = FORCFD OUTAGE liOUPS
  • 100 lit!5TT'IIGTON-LINE + IGTIII DUTAGli IIOWS

4041 JUNIB H.in. M Ag '

UNIT K?Ft GENERATING PIANT i

sg9my Operated as Base

~

i Loaded Unit until DAlii 10-7-75

. Unit removed fran service on.9/11/75 for REIUT BONIll Sept mber CGTLETED IiY W. A. Shaala l

Refueling.-

U';IT S!UTD7045 s

Ti'PE MEI Ob OF F-FORCIF IURATION S!UTTING FCC; No.

DATE S-SGIEIULED (HOURS)

REASON (1)

'Iid RDCiDR G)

CO'IC.~tS 11 8/31/75 F

10.4 A

3 This is a continuation of the outage which started 8/31/75.

g Total duration of Outage was 12.1 hours1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br />.

g 12 9/11/75 S

462.7 C

1 i

4 I

(1) FDSON:

(2) 3'EITED I

A-EQUIIET FAILURE (EXI'1AIN) 1-31'0E1%

3-M\\IN. CR TEST 2 'UliliL l

I C-REFUELI';G SCRX-!

I D-REGILiTGRY RESTRICTION 3-!4TIU GT E-CPIA1 TOR TRAINIG G SCR*44 LICENSE EXIJIIX; TION i

F-AININISTPATIVE G-OPERATIONAL ERPfR l

(Explain)

H-0 TIER (Explain)

.r

., ~.

i 2025 tbnticello Nuclear

{

.. 5 UNIT Generatinn I'lant Intl!,,_Ocjojer 4 1975

- Qttiti:'llD liY,,,j%.Slmla P

4 fly llNIT loh1.It ungg hDMill September I E

' net l

-net DAY AVEMGliIOURLY ?IWe

!Y AnlMGE IlGJIEY M'io 1

._119 _.

25

- 21._

2 26$

26

-2_

3 293 27

-2 4

289 28

-2 291 29

-J__,..

5

~

..._ - 2.__

6 285 30 7

285 31 8

288 9

283 10 283 11 186 12

-4.7 13

-4.7 14

-5.3 15

-3.5 16

-4.7

'17

-4.0 18

-4.7

-23 19 20

-2.3 ---

21

-2

[

22

-2 23 2

24

-2

=,

L t

r

'e-,,-.-r-~

.. e nA n--w,-

-,c,

'w+

.,,.-,.w..vn>..,

,. 5 N +n -.

a

,w.

n n

-w--u,-

e

,,,+-~+---,-na--wen,N,,,av.r,,,wr=,

~

~

s

,,,.--ar.--w.-