ML20127P004

From kanterella
Jump to navigation Jump to search
Monthly Operating Rept for Feb 1977 for Monticello Nuclear Generating Plant
ML20127P004
Person / Time
Site: Monticello Xcel Energy icon.png
Issue date: 02/28/1977
From: Mayer L, Shamla W
NORTHERN STATES POWER CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE)
References
NUDOCS 9212010477
Download: ML20127P004 (4)


Text

_ _.

_ -. ~ _ _.

- _. - ~ ~. _ - _.

~ -. _ _. -

NSP NOMTHERN 5 TATE 5 POWER COMPANY M I N N E A P O 4.i t. M 4 N N E 9 0T A 95401 i

f March 8, 1977 g.ta,0scaa n. ice gg b

Director, Office of Og hg8Mg.~7 Inspection and Enforcernent 4

U S Nuclear Regulatory Cocnission g% %

Washington, DC 20555

Dear Sir:

I j' 1

MONTICELLO NUCll%R GI2iERATING PIANT Docket No. $0-263 License No. DPR-22 Monthly Operating Report February 1977 Attached are ten copies of the Monthly Operating Report for February,1977 for the Monticello Nuclear Generating Plant.

Yours very truly, x'O.hy L 0 Mayer, PE Manager of Nuclear Support Services IDM/ak cc:

Director, IE-III, USNRC (1)

Director, MIPC, 'JSNRC (2) 9212010477 770220

{DR ADOCK0500g3

,y

202b +

  • Rev i i

'P/13!.76 OPl:llATING llATA RI.!' ORT lo:htT !.o.

50 265 UNIT 1

= _ _ _.. _

iaTi.,_MARQQ_1977 CG@ LID ID 1 A W. A. SlWiLA TEll:l'l!ON1!

612/295-5.151, & t. ]IL ariENG STA'IUS l'EBRUARY 1.

Reporting Perin.1:

Gror Hours in Re! ort l'eriod:

672 2.

Currently Authorized Power Level (Wt):

1670 Max. l)epend. Capat. tty (bMc-htT):

Ji36

_ Design Electrical llating (blwe-TEti:

5 f5. J.

N/A 3.

PNer Level to hhich Restricted (if any) (We Net), _

4 Reasons for Restriction (if any):

Tills bONni YR TO IMTE CU41LAT]VH 5.

thaber of flours Reactor Was Critical...........

656.2 1,400.2 39,476.6 6.

Reactor Reserve Shutdown llours............,....

0.0 0.0 940.7 :

7.

Ilours Generator On Line........................

650.2 1,394.2 38,169.4 3,

Unit Reserve Shutdown llours....................

0.0 0.0 0.0-

i. Cr
ss Thent.a1 Energy Cencrated (SMI)........... 1,042.192.8 2,270,522.4

. 64 933,197.8 >

t 10.

to;s Electrical Energy Generated (tWI) 354,670 774.810 19,419.230

11. Net Electricai Enerr;y Generated (Wil)..........

341,514 746,294 18,553166-

'?.

Ructor Servic e Fac tor.............. s.......,

97.6%

98.9%__

79.3%l Th.: tor Availani114 Factor....................

97.6%

98.9% _

81. 2 %'

a.

' 13 Um t Service Factar............................

96.8%

98.5%

76.7%i

-. a Availability Factcr.......................

96.8%

98.5%

76.7%

'i. Unit Capaci ty ?acrcr (U.ung tilX )...........

9_8. 3%

69.6%

94.8%

17 Uni: Copacity Fcc :or (Using Design We)........,_,

93.2%

. 96.6%

68.4%

1 ;i. Unit Forced Datage Rate........................ _

3.2%

1.5%

9.0%

33.

Shutdowns Scheduled over Next 6 Months (Type, Date and Duration of Each):

20.

If Shutdown at 2nd of Report Period Estimated Date of Startup:

P s

--l,-

,.,n

-...,e m

.e y

c,N -N,

---e-,--

?

. - -. _ ~ - -

f

  • 2025

'c Rev. 0

' 3/3/76 I

.71% e f. M11Y 11NJT in'nt IJYEl.

I

-.. 2 6_3. _...

50 5

DOCKliT 10.

IfNIT 1

IMTE.MA.ROL,1..s.1977 (XMPLir113) 11Y W. A. SIW41A TEllPID'ai 612/29L-5151. Ext.111-WNm FEBRUARY 1977 i'

1RY AVERAGE !nlLY K1h131 LLVFL DAY AVDIACli In11.f M.3 LINiiL (4'e-Net J pu 4: '

1

.. _.54 9 17 549

?

550 u

551 3

549 la 548 525 4

550 20

.. =

4 547 21 549 6

528 22-547 23 155-7

.. 547 548 21 153 3

9 545

'/ ',

418 N

545 o

507 551 11 S43 e.

12-

'467 m:

548 - - - -.__

13 527 14 543 30 15.

54 7 31 546 16 i

o l

---...-..-_......,m,

---,+-.m.,--,

.. m

-_,-,m.___,

..=

2027-

'Rev. 0

3/3/76' DOCKET NO.

50-263 UNIT.WIE Monticello UNIT S!iTIIUCS AND PotER RFlXETIONS DATE F4/77 u.L..*vinsii, Engr.

CTFLETED EY. for W.A. hila RFJORT ttT:rH February 1977 TELEriC I s12/295-5151 1_* t. til I

- r

'.'EI1G OF i

N SLTiTING DGG F: FORCED DURATION D E REACTOR OR NO.

.DATE S: SCI G ULED URS)

Rii\\SCG (1)

REIXEI?G IUiER (2)

CORRfCTIE.iClil0NS/C0rt!ENTS 1

2/23/76 F

21.8 A

3 Plant restarted and line repaired.

Inss of 345 KY Line Due To Icing During Winter Storm (2) Em (1) REASON 1: h ual A: Equipment Failure (Explain)

': Manual Scram B: Maint. or Test 3: Automatic Scram C: Refueling 4: Other (Explain)

D: Regulatorv Restriction E: Operator Training and License Examination STf41RY:

Inad rejection scram occurred F: Administrative at 0659 2/23/77: unit G: Operational. Error Uxplain) re-s*7ch..at 0445.2/24/77.

": Other (Explain)

~,.

~.

.