January 25, 1993 Docket No. 52 003 MEMORANDUM FOR:

Richard W. Borchardt, Acting Director Standardization Project Directorate Associate Directorate for Advanced Reactors and License Renewal, NRR FROM:

Frederick W. Hasselberg, Project Mandgar Standardization Project Directorate Associate Directorate for Advanced Reactors and License Renewal, NRR

SUBJECT:

00TICE OF MEETING WilH VESTINGHOUSE TO OBTAIN ADDITIONAL.

INFORMATION ON AP600 VALVES DATE & TIME:

February 5, 1993 (8 a.m. - 2:30 p.m.)

LOCATION:

Westinghouse Energy Center Monroeville, Pennsylvania PURPOSE:

To obtain detailed design information on selected AP600 valves in critical operational applications. A meeting agenda is enclosed.

NOTE:

Proprietary features of the AP600 design will be discussed.

PARTICIPANTS:

R(

WESTINGHOUSE ort 1

0. fischer C. Brockhoff J. Kueck T. Sullivan S. Fanto D. Casada R. Hasselberg P. Vock K. McElhaney l

J. Butler R. Staunton l

Ori halSi td B 9

FrederickW.hasscI'terg,ProjectManager I

4 Standardization Project Directorate Associate Directorate for Advanced Reactors ano License Renewal, NRR cc:

See next page 1

  • Meetings between NPC technical staff and appiicants or licensees are open for

^

interested members of the public, petitioners, intervenors, or other parties to attend as observers pursuant to "Open Meeting Statement of NRC Staff Policy," 43 Le_@nl Renis.tsr 20858, June 28,1970.

However, portions of this meeting may be closed to protect Westinghouse proprietary information.

i Members of the public who wish to attend should contact me at (301) 504-1141.

ulSJRl0_V.H03:

See next page O

f LAbbST: AR PM:P09T:.DAR SC:Pbk 0FC:

'01@q$ar:ADAR g

PShea t

FHav erg:sg NAME:

RBo dt l01 1

93 01/6/93 DATE:

93 b[g 0FFICIAL RECORD C0"Y:

DOCUMENT NAME: VALVES.N0T

^

9301290247 930125 a

PDR ADOCK 0"i2OOOO3 A

PDR

d s

NRC/ WEST 1RGJJ2$LVALYr M((11))q FEBRUARY 5, 1993 AGENDA

~

1.

INTRODUCTION Butler Hasselberg (NRC) 2.

MOTOR-OPERATED VALVES

AIR-0PERATED VALVES

  • ADS Stage 4 ADVs Core Makeup Tank Inlet A0Vs Core Makeup Tank Discharge A0Vs Passive RHR Heat Exchanger Discharge A0Vs 4.

CHECK VALVES

  • IRWST Gravity injection CVs Containment Recirculation Line CVs Core Makeup Tank Discharge (Tilt Disc) CVs Core Makeup Tank Pressurizer Pressure Balance Line CVs 5.

SQUlB VALVES

  • pH Adjustment Tank Discharge Squib Valves
6., CONCLUSION / DISCUSSION PRESENTATION KATERIAL FOR EACH VALVE (as requested / required)

System Configuration Schulz Valve Functional Requirements and Design Parameters Schulz Valve Design Information Vock Valve lesting Information Fanto Miscellaneous Questions As required Enclosure l-l I

t Docket No.52-003 Westinghouse Electric Corporation AP600 cc:

Mr. Nicholas J. Liparulo Nuclear Safety and Regulatory Analysis NL. clear and Advanced Technology Division Westinghouse Electric Corporation P.O. Box 355 1

Pittsburgh, Pennsylvt.nia 15230 l

Mr. B. A. McIntyre Advanced Plant Safety I Licensing Westinghouse Electric Corporation Energy Systems Business Unit Box 355 Pittsburgh, Pennsylvania 15230 Mr. John Butler Advanced Plant Safety & Licensing llestinghouse Electric Corporation P.O. Box 355 Pittsburgh, Pennsylvania 15230 Mr. M. D. Beaumont Nuclear and Advanced Technology Division Westinghouse Electric Corporation One Montrose Metro 11921 Rockville Pike Suite 450 Rockville, Maryland 20852 Mr. Daniel F. Giessing U. S. Department of Energy NE-42 Washington, D.C.

20585 Mr. S. M. Modro EG&G Idaho Inc.

Post Office Box 1625 Idaho Falls, Idaho 83415 Mr. Steve Goldberg-Budget Examiner 725 17th Street, N.W.

_ Room 8002 i

Washington, D.C.

20503 l

.i Mr. Frank Ross U.S. Department of Energy NE-42 Washington, D.C.

20585 i

j O

\\

i l

DIEIR10.41198:

(Docket File '

l PDR PDST R/F l

TMurley/FMiraglia,12G18 DCrutchfield RBorchardt FHasselberg 3

TKenyen PShea i

Achaffee, EA3 j

i JMoore, 15318 i

1 BGrimes, 9A2 EJordan, MNBB370)

CRossi, 9A2 i

GGrant, EDO j

ACRS (11)

OPA PO' Dell, PTSB j

CHcCracken, 8D3 BPerch, 8H7 l

0Fischer, 7E23 TSu111 van, 7E23 i

NRR Mailroom, 12G18 1

i t

i i

n i

l 1

4 1

l k

.t k

b

-