Text
_
June 20, 1985 i
Mr. J. H. Taylor, Manager DISTRIBUTION Licensing Services
- Central Files' Babcock & Wilcox NRC PDR --
3315 Old Forest Road DCS Post Office Box 10935 SSPB R/F lynchburg, Virginia 24506-0935 DMoran PDipps
Dear Mr. Taylor:
PNoonan
SUBJECT:
ACCEPTANCE FOR REFEREllCIfiG OF LICENSING TOPICAL REPORT BAW-10145P,
" STATISTICAL CORE DESIR! APPLIED TO THE BABC0CK-205 CORE" Pe have completed our review of the subject topical report submitted by Babcock & Wilcox (B&W) by letter dated December 10, 1980. We find the report to be acceptable for referencing in license applications to the extent specified and under the linitations delineated in the report and the associated NRC evaluation, which is enclosed.
The evaluation defines the basis for acceptance of the report.
Pe do not intend to repeat our review of the matters described in the report and found acceptable when the report appears as a reference in license applications, except to assure that the material presented is applicable to the specific plant involved. Our acceptance applies only to the matters described in the report.
In accordance with procedures established in NUREG-0390, it is requested that B&W publish accepted versions of this report, proprietary and non-proprietary, within three months of receipt of this letter.
The accepted versions shall incorporate this letter and the enclosed evaluation betweer the title page and the abstract. The accepted versions shall include an -A (designating accepted) following the report identification symbol.
Should our criteria or rerlulations change such that our conclusions as to the acceptability of the report are invalidated, B&W and/or the applicants t
i referencing the tcpical report will be expected to revise and resubmit their respective documentation, or submit justification for the continued effective applicability of the topical report without revision of their respective documentation.
Sincerely, Original signed by Cecil 0. Thomas, Chief Standardi7ation and Special I
Projects Branch J
Division of Licensing
/
Enclosure:
/
As stated Vq i
P c. nan:dk an o
F/[ /P5 Cy0(/PF p /s,e/85 6/ys/85 8507010372 850620 PDR TOPRP ENVDW C
mn
/
E UNITED STATES
~
NUCLEAR REGULATORY COMMISSION n
h WASHINGTON, D. C. 20555
%.,,,/
June 20, 1985 Mr. J. H. Taylor, Manager Licensing Services Babcock & Wilcox 3315 Old Forest Road Post Office Box 10935 Lynchburg, Virginia 24506-0935
Dear Mr. Taylor:
SUBJECT:
ACCEPTANCE FOR REFERENCING OF L' CENSING TOPICAL REPORT BAW-10145P,
" STATISTICAL CORE DESIGN APPLIED TO THE BABC0CK-205 CORE" We have completed our review of the subiect topical report submitted by Babcock & Wilcox (B&W) by letter dated December 10, 1980. We find the report to be acceptable for referencing in license applications to the extent specified and under the limitations delineated in the report and the associated NRC evaluation, which is enclosed. The evaluation defines the basis for acceptance of the report.
We do not intend to repeat our review of the matters described in the report and found acceptable when the report appears as a reference in license applications, except to assure that the material presented is applicable to the specific plant involved. Our acceptance applies only to the matters described in the report.
in accordance with procedures established in NUREG-0390, it is requested that B&W publish accepted versions of this report, proprietary and non-proprietary, within three months of receipt of this letter.
The accepted versions shall incorporate this letter and the enclosed evaluation between the title page and the abstract.
The accepted versions shall include an -A (designating accepted) following the report identification symbol.
Should our criteria or regulations change such that our conclusions as to the acceptability of th report are invalidated, B&W and/or the applicants referencing the topical report will be expected to revise and resubmit their respective documentation, or submit,iustification for the continued effective applicability of the topical report without revision of their respective documentation.
Sincerely, GA O. %==.
Cecil 0. Thomas, Chief Standardization and Special Projects Branch Division of Licensing
Enclosure:
As stated
i Babcock 5 Wilcox Company Docket No. 50-13 cc: Executive Secretary of Campbell County Rustburg, Virginia 24588 Commonwealth of Virginia Council of the Environment 903 Ninth Street Office Building Richmond, Virginia 23219 Attorney General 1101 East Proad Street Richmand, Virginia 23219 t
{
i i
w i
e f
k