Amends 102 & 95 to Licenses DPR-42 & DPR-60,respectively, Deleting Requirements Re Chlorine Detectors
ML20127M661
Person / Time
Site: Prairie Island  
Issue date: 09/29/1992
From: Marsh L
Office of Nuclear Reactor Regulation
To:
Shared Package
ML20127M665 List:
References
NUDOCS 9211300374
Download: ML20127M661 (10)


Text

_ _. _. _ _ _, _ _ _. _... _.... -.. _ - _ _ _ _ _.

+ g ass g

'k

[f UNITED STATES NUCLEAR REGULATORY COMMISSION

.e o

5 I

W AEHING T ON, D. C. 20665 s

a*

%,...../

NORTHERN SIATE5 POWER COMPANY DOCKET NO. 50-282 PRAIRIE ISLAND NUCLEAR GENERATING PLANT. () NIT NO. I AMENDMENT TO FACILITY OPERATING LICENSE Amendment No.102 License No. DPR-42 1.

The Nuclear Regulatory Comission (the Comission) hks found that:

A.

The application for amendment by Northern States Power Company (the licensee) dated December 13, 1991, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act),

and the Comission's rules and regulations set forth in 10 CFR-Chapter I; B.

The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Commission; C.

There is reasonable assurance (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Comission's regulations; D.

The issuance of this amendment will not be inimical to the comon defense and security or to the health and safety of the public; and-E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Comission's regulations and all applicable requirements have been satisfied.

2.

Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment, and paragraph 2.C.(2) of facility Operating License No. OPR-42 is hereby amended to read as follows:

L l:

l l

9211300374 92o929 PDR ADOCK 05000282 P-

.PDR.

Technical Specifications The Technical Specifications contained in Appendix A, as revised 3

through Amendment No.102 are hereby incorporated in the license l3.

The licensee shall operate the facility in accordance with the Technical Specifications.

This license amendment is effective as of thr. dite of its issuance, FOR THE NUCLEAR REGULATORY COMMISSION a

ledyard B. Mar:;h, Director Project Directorate 111-1 Division of Rafactor Projects Ill/IV/V Office of Nuclear P,eactor Regulation

Attachment:

Changes to the Technical Specifications Date of Issuance: September 29, 1992

)

m t

9 ATTACHMENT TO LICENSE AMENDMENT NO.102 FACIllTY OPERATING LICENSE NO. DPR-42 DOCKET NO. 50-282 Revise Appendix A Technical Specifications by removing the pages identified below and inserting the attached pages. The revised r:9es are identified by amendment number and contain vertical lines indicatii9 s-area of change.

REMOVE INSERT TS-iv TS-iv TS.3.13-2 B.3.13-1 B.3.13 1 l

I

l i

TS iv TABLE OF CC"TDrrS (continued)

II SECTION TITLE PACE 3.10 Control Rod and Power Distribution Limits TS.3.10-1 A. Shutdown Margin TS.3.10-1 B. Power Distribution Limits TS.3.10-1 C. Quadrant Power Tilt Ratio TS.3.10-4 D. Rod Insertion Limits TS.3.10 5 E. Rod Misalignment Limitations TS.3.10 6 T. Inoperable Rod Position Indicator Channels TS.3.10 6 C. Control Rod Operability Limitations T3.3.10-7 H. Rod Drop Time TS.3.10-7 I. Monitor Inoperability Requirements TS.3.10 8 J. D.4B Farameters TS.3.10 8 3.11 Core Surveillance Instrumentation 3.12 Snubbers TS.3.11-1 TS.3.12-1 3.13 Control Room Air Treatment System TS.3.13 1 Control Room Special Ventilation System TS.3.13-1 A.

3,14 Fire Detection and Protection Systems l

TS.3.14-1 A. Fire Detection Instramentation TS.3.14-1 B. Fire Suppression Water System TS.3.14-1 C. Spray and Sprinkler Systems TS.3.14-2 D. Carbon Dioxide System TS.3.14 3 E. Fire Hose Stations TS.3.14-3 F. Yard Hydrant Hose Houses 1S.3.14-4 C. Penetration Fire Barriers TS.3.14-4

\\

3.15 Event Monitoring Instrumentation TS.3.15-1 A. Process Monitors Th.3.15 1 B. Radiation Monitors TS.3.15-1 C. Reactor Vessel Level Instrumentation TS.3.15-2 L

Amendment No. 73, 9f, 95, 102,

l B.3.13-1 3.13 CONTROL ROOM AIR TREATMENT. SYSTEM Bases The Control Room Special Ventilation System is designed to filter the Control Room atmosphere during accident conditions. The system is designed to automatically start on a high radiation signal in the ventilation air or when a Safety Injection signal i.s received from either unit. Two co 9 stely 1

redundant trains are provided.

Each train has a filter unit consisting of a profilter, HEPA filters, and charcoal adsorbers. The HEPA filters remove particulates from the Control Room atmosphere and prevent clogging of the iodine adsorbers. The charcoal adsorbers are installed to remove any radiciodines from the control Room atmosphere.

OS h h

Amendment No. 91, 84, 102,

7 p tag jf jgj UNITED STATES -

d

.. a g

NUCLEAR REGULATORY COMMISSION y

' l WASHINGTON, D C. 20655 k....,/

4 1

NORTHERN STATES POWER COMPANY DOCKET NO. 50-306 PRAIRIE ISLAND NUCLEAR GENERATING PLANT. UNIT NO. 2 AMENDMENT TO FACILITY ODERATING LICENSE Amendment No. 95 License No. DPR '

1.

The Nuclear Regulatory Commission (the Commission) has found that:

A.

The application for amendment by horthern States Power Company (the licensee) dated December 13, 1991, complies with the standards ~and-requirements of the. Atomic Energy Act of 1954, as amended-(the Act),

and the Commission's ru?es and regulations set forth in 10 CFR Chapter I; B.

The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the romr.iission; C.

There is rcasonable assurance-(i) that the activities authoriz.1 by-this amendment can be conducted without endangering the health and safety of the public, and~-(ii) that such activities will be conducted in compliance with the Commission's regulations; D.

The issuance of this amendment wil! not be inimical.to the common defense and security or to the health and safety of the public; and E.

The issuance of this amendaent is in accordance with 10 CFR Part 51 of the Commission's regulations ano all-applicable requirements.have; been satisfied.

2.

Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment, and paragraph 2.C.(2) of Facility Operating License No.~DPR-60 is hereby amendedito read as follows:

~

~2-Iechnical Specifhations The Technical Specifications contained in Appendix A. as revised through Amendment ho.95, are hereby incorporated in the license.

The licensee shall operate the facility in accordance with the Technical Specifications.

3.

This license amendment is effective as of the date of its issuance.

FOR THE NUCLEAR REGULATORY COMMISSION

, i/ h Ledyard B.' Marsh, Director Project Directorate 111-1 Division of Reactor Projects III/IV/V Office of Nuclear Reactor Regulation

Attachment:

Changes to the Technical Specifications Date of issuance:

Septenber 20, 1992 1

. - ~,

t ATTACHMENT TO LICENSE AMENDMENT NO. 95 FACILITY OPERATING LICENSE NO. DPR-60 DOCKET NO. 50-306 Revise Appendix A Technical Specifications by removing the pages identified below and insertir d contain vertical lines indicating the area of change.

the attached pages. The revised pages are identified by amendment number an REMOVE INSERT TS-iv TS-iv TS.3.13-2 B.3.13-1 B.3.13-1 1

)

TS-iv TABLE OF CONTENTS (Continued)

TS SECT ES

'ilTLE PACE 3.10 Control Rod and Power Distribution LLaits TS.3.10 1 A. Shutdown Margin TS.3.10-1 B. Power Distribution Limits TS.3.10 1 C. Quadrant Power Tilt Ratio TS.3.10 4 D. Rod Insertion Limits TS.3.10 5 E. Rod Misalignment Limitations TS.3.10 6 F. Inoperable Rod Position Indicator Channels TS.3.10 6 G. Control Rod Operability Limir tions H. Rod Drep Time TS.3.10 7 TS.3.10-7 I. Monitor Inoperability Requirements J. DNB Parameters TS.3.10-8 TS.3.10-8 3.11 Core Surveillance Instrus.sntation 3.12 Snubbers TS.3.11-1 TS.3.12-1 3.13 Control Room Air Treatment System TS.3.13 1 A. Control Room Special Ventilation System TS.3.13-1 3.14 Fire Detection and Protection Systems l

TS.3.14-1 A. Fire Detection Instrumentation TS.3.14-1 B. Fire Suppression Water System TS.3.14-1 C. Spray and Sprinkler Systems TS.3.14-2 D. Carbon Dioxide System E. Fire Hose Stations TS.3.14-3 TS.3.14 3 F. Yard Hydrant Hose Houses TS.3.14-4 G. Penetration Fire Barriers TS.3.14 4

.S.15 Event Monitoring Instrumentation A. Procets Monitors TS.3.15-1 B. Radiation Monitors TS.3.15 1 TS.3.15-1 C. Reacto+ i~assel Level Instrumentation TS.3.15-2 Amendment No. Eg, 84, 87, 95,

9 3.3.13 1 3.13 C3h' TROL ROOM AIR TREATMENT SYSTEM Bases The Control Room Special Ventilation System is dorfgned to filter the Control Room atmosphere during accident conditions. The system is designed to automatically start on a high radiation signal in the ssntilation air or whsn a Safety inject.4co signal is received from either unit. Two completely redundant trains are provided.

Each train has a filter unit consisting of a profilter, HEPA filters, and charcoal adsorbert., The HEPA filters remove particulates from the Control Room atmosphere and prevent clogging of the iodine adsorbers.

The charcoal adsorbers are installed to remove any radiciodines from the control Room a tmosphe re.

1 Amendment No. 91, 8#, 95

--