a s t op'.
UNITED STATES
[
4 4
p*
4 NUCLEAR REGULATORY COMMISSION REolON IV URANIUM RECOV FIELD OFFICE DENVER, COLORADO 80225 URF0:PWM
' Docket No. 50-267 MEMORANDUM 10:
L. J. Callan, Director Division of Radiation Safety and Safeguards Region IV FROM:
R. E. Hall, Director Uranium F.ecovery Field Office, Region IV
SUBJECT:
FORT ST. VRAIN INSPECTION PLAN The inspection plan for Fort St. Vrain, which Paul Michaud has developed for the current fiscal year, ending on September 30, 1993, is attached. This plan is based on MC 2560, Decommissioning Inspection Program. The frequency and estimated hours for performing each inspection module were based on an allocation of approximately one-half an FTE for all inspection activities.
The status of the facility, scheduled decommissioning activities, the relative need and difficulty of performing each inspection module, and a planned 8-week report frequency were considered in the allocation of these resources.
The main activities for this inspection period will be associated with cutting and dismantlement of the Prestressed Concrete Reactor Vessel (PCRV) top head.
This can not begin until the removal of the dummy fuel blocks from the PCRV has been completed, which is currently behind schedule and not likely to be finished until February,1993. Other significant activities will include installation of the PCRV shield water system, management and transportation of radioactive waste, and design and preparation for PCRV internals dismantlement.
Preparation for these activitles will include training of Pete Garcia and Dana Ward so they can be inttgrated into inspections at Fort St. Vrain.
We will implement the attached inspection plan as written unless you have comments or changes. Should facility status or schedules change, we will respond to these changes as necessary.
WP Ramon E. Hall Director
Attachment:
^
9301280023 921127 PDR ADOCK 05000267 P
PDR 3
l
NOV 271992 2
cc:
J. Austin L. Pittiglio
'N
2 3
bec:
Docket No. 50-267 POR/DCS URF0 r/f LJCallan, RIV LLUR Branch, LLWM PWMichaud 0:\\lNSPECT\\FSVINSPl.MEM
.. AW DD:URF0Ty/w TjIUROhRIV PWMichaud/db EFHawkins REHall 11/2f/92 11/7_p92 11/27/92
FORT ST. VRAIN INSPECTION PLAN
~
Program: MC 2560, Decommissioning Inspection Program Inspection Period: December 1, 1992 to September 30, 1993 Responsibility: URF0 P_ROCEDURE TITLE FRE0VENCY EST. HRS.
Core inspection Proaram 64704 Fire Protection / Prevention Program SA 16 71707 Operational Safety Verification M
120 80721 Radiological Environmental Monitoring SA 16 81018 Security Plan & Implementing Procedures M
10 82701 Operational Status of Emergency A
8 Preparedness Program 86700 Spent Fuel Pool Activities M
10 86750 Solid Radioactive Waste Management and M
90 Transportation of Radioactive Materials l
l Realonal initiative Inspection Proaram l
30703 Management Meetings M
10 35701 Quality Assurance Annual Review A
8 368008 Organization A
8 l
-.i
.-r
2 PROCEDURE TITLE FREQUENCY EST. HRS.
Core inspection Program 39701 Records Program A
8 40702 Audit Program M
64 41400 Non-Licensed Staff Training A
8 42700 Plant Procedures SA 16 54834B Housekeeping Controls SA 16 61700 Surveillance Procedures and Records SA 16 62702 Maintenance Program SA 16 81020 Management Effectiveness - Security A
8 Program 83100 Occupational Exposure During DECON SA 16 83722 Radiation Protection, Plant Chemistry, A
8 and Radwaste: Organization and Management Conttols 83723 Training and Qualifications: General A
8 Employee Training, Radiation Safety, Plant Chemistry, Radwaste and Transportation 83890 Closcout inspection and Survey AR 0
84101 Radioactive Waste Management SA 16
,i-,.,
e--,,E,~m,3
.m.
.,... ~
o P
3 EROCEDURE TITLE FREQUENCY EST. HRS.-
~
Core inspection Procram 86721 Transportation A
Note 1 o
92701 Followup AR 8
92720 Corrective Action AR 8
93001 OSHA Interface Activities AR 8-Total Inspection Hours 520 M - MONTHLY SA - SEMIANNUALLY A - ANNUALLY AR - AS REQUIRED
'l Note 1:
Inspection of Transportation Activities to be conducted December 1 to 3,1992, by the Transportation Branch, Division of Safety and Transportation.
w,v r e-. A,
>-v, r.r-
-w, ww g-f