Responds to Request for Addl Info Re Draft SER Open Item 101 on Source Range Instrumentation for High Flux at Shutdown Alarm.High Alert Associated W/Instrument Analog Input Programmed W/Setpoint Equivalent to Shutdown Alarm
ML20127L649
Person / Time
Site: Vogtle  
Issue date: 06/14/1985
From: Bailey J
GEORGIA POWER CO.
To: Adensam E
Office of Nuclear Reactor Regulation
References
GN-642, NUDOCS 8506280080
Download: ML20127L649 (1)


Text

m Georgia Power Company Routa 2, Box 299A Wayn;sboro, Georgia 30830 Telephone 404 554-9961 404 724-8114 Southern Company Services, Inc.

Post Off.ce Box 2625 Birmingham, Alabama 35202 Telephone 205 8706011 Vogtle Proj.ect June 14, 1985 Director of Nuclear Reactor Regulation File: X7BC35 Attention:

Ms. Elinor G. Adensam, Chief Log:

GN-642 Licensing Branch #4 Division of Licensing U. S. Nuclear Regulatory Commission Washington, D.C.

20555 Ref: Bailey to Denton, GN-629, Dated 5/29/85 NRC DOCKET NUMBERS 50-424 AND 50-425 CONSTRUCTION PERMIT NUMB"RS CPPR-108 AND CPPR-109 V0GTLE ELECTRIC GENERATING PLANT - UNITS 1 AND 2 REQUEST FOR ADDITIONAL INFORMATION: DSER OPEN ITEM 101

Dear Mr. Denton:

This is to confirm that the source range instrunentation cited in the reference letter consists of two redundant channels with separate Class 1E power supplies and a bisteble for each channel providing input to the High Flux at Shutdown Alarm.

There is a ' single e.larm on the main control board, however, the source range instrumentation does pbovide analog.

input to the Proteus computer. There is a "High Alert, associated with this input which will be programmed with a setpoinr equivalent to the setpoint for the High Flux at Shutdown' Alarm. Any process point which goes into the alarm state causes an'alars'tessipp to appear,on a CRT, screen dedicated to this purpose. Alarm Nas' ages, Are writter. S th the l'

i point identification in the blinicing state. 'Plantbrocedurespill ~ '

require that the setpoint programmed into the compure M e adjusted to account for decay in activity during' shutdown.

s If your staff requires any additlownf information, please ?do not. hesitate

(

'i'%-

to contact me.

s s

Q a

y m

Sincerely, y

s

,s l

.,,\\

?

,. y ;

t

. A. Bailey Project Licensing Manager 2

E pp -

JAB /caa g.

y',

Enclosure Q

']

J xc:

D. O. Foster..

G.'Bockhold, Jr R. A. Thomas' II.. H. Gre' gory, III.

g\\

J. E,. Joiner.- Esquire T. Johnson B. W. Churchill,$ squire ^

.D. C.'Teser

. Tr, O M. A. Miller y

~Le Fowler B. Jones,' Esquire <

t 'Vogtle Project f'ile L. T. Cucwa

.y 0205m

' b ~1

.-[ ' -

N' pG s

4

~u s%

.-...