ET-NRC-93-3797, Forwards Responses to NRC 920622 Request for Addl Info Related to AP600 Containment Design,Rcs Design & Details on 1/8 Scale Containment Test Facility.Responses Withheld. Proprietary Portion of Document Sent to Westinghouse

From kanterella
(Redirected from ML20127L546)
Jump to navigation Jump to search
Forwards Responses to NRC 920622 Request for Addl Info Related to AP600 Containment Design,Rcs Design & Details on 1/8 Scale Containment Test Facility.Responses Withheld. Proprietary Portion of Document Sent to Westinghouse
ML20127L546
Person / Time
Site: 05200003
Issue date: 01/19/1993
From: Liparulo N
WESTINGHOUSE ELECTRIC COMPANY, DIV OF CBS CORP.
To: Murley T
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML20127L549 List:
References
ET-NRC-93-3797, NUDOCS 9301270200
Download: ML20127L546 (2)


Text

--

3

(

i'

,, 7 J.

Westinghouse _

Energy Systems em ass-Electlic Corporation P6ttsburgn Pennsytvania 15230 0355 ET-NRC-93 3797-NSRA-APSL-93-0007.

j Docket No.: STN 5?-003 January 19,1993 Document Control Desk U.S. Nuclear Regulatory Commission Washington, D.C. 20555 ATTENTION:

DR. THOMAS MURLEY 1

SUBJEC1':

NRC REQUEST FOR ADDITIONAL INFORMATION RELATED TO AP600.

DESIGN

REFERENCE:

LETTER FROM HASSELBERG (NRC) TO L.!PARULO (WESTINGHOUSE)-

DATED JUNE 22,1992

Dear Dr. Murley:

Please find attached responses to the requests for additional information related to the AP600 design transmitted by the referenced letter. The reference letter requests information pertaining to the AP600 containment design, reactor coolant system design and details on the 1/8 scale containment test facility.--

Attachment A contains a summary of the information requested in the reference letter.

The Westinghouse Electric Corporation copyright notice, proprietary information notice, application for withholding and affidavit are also attached.

This submittal contains Westinghouse proprietary information_ consisti_ng of trade secrets, commercial-information or financial information which we consider privileged or confidential pursuant to-10CFR9.17(a)(4). Therefore, it is requested that the Westinghouse proprietary information attached hereto be handled on a confidential basis and be withheld from public disclosures.

This material is for your internal use only and may be used for the purpose for which it is submitted.

It should not be otherwise used, disclosed, duplicated, or disseminated, in whole or in part, to any other person or organization outside the Commission, the Office of Nuclear Reactor Regulation or the Office of Nuclear Regulatoiy Research without the express written approval of _ Westinghouse.

Correspondence with respect to the application for withholding should reference AW-93-398, and should be addressed to N. JJ Liparuto, Manager of Nuclear Safety And Regulatory Activities, Westinghouse Electric Corporation, P.O. Box 355, Pittsburgh, Pennsylvania, 15230-0355.

i 25006'?

37 L

i iin h ' )A//)4: d

\\

9301270200 930119 PDR ADOCK 05200003 A

PDR

ET-NRC-93-3797 NSRA-APSt 93-(XX)7 January 19,1993 Please contact Brian A. McIntyre on (412) 374-4334 if you have any questions concerning this transmittal.

i N ~'(

N. L 'parulo, Manager Nuclear Safety & Regulatory Activities

/nja Attachment ec:

F. Hasselberg, NRC R A. McIntyre, Westinghouse

.o 0747A

_ __J