ML20127K880
| ML20127K880 | |
| Person / Time | |
|---|---|
| Site: | Monticello |
| Issue date: | 09/25/1973 |
| From: | Mayer L NORTHERN STATES POWER CO. |
| To: | Oleary J US ATOMIC ENERGY COMMISSION (AEC) |
| References | |
| NUDOCS 9211230307 | |
| Download: ML20127K880 (1) | |
Text
1 Ri~gulal0ry D00'gl utB NSP NORTHERN STATE 5 POWER COMPANY M A N N E A Pol.l S. M IN N E S OTA SS401 s MM~ /
g'
~#
September 25, 1973 k "%
on
.'3 i ' _. Q; %, -
8 x
3 SEP 281973 * :-
n Mr. J. F. O' Leary, Director k
$Ng 1
I" '>
Directorate of Licensing 2
tg1 um Office of Regulation
'Q.,
O 8
b,i United States Atomic Energy Commission 7y c3 T,
Washington, DC 20545 Dear Mr. O' Leary MOSTICELLO NUCLEAR GENERATING PIANT Docket No. 50-263 License No. DPR-22 Sodium Pentaborate Solution in No. 12 SBLC Pump Lubricating 011 A condition occurred at the Monticello Nucicar Generating Plant which we are reporting to your office in accordance with Section 6.7.B.1. Abnormal occurrence Reports, of the Appendix A Technical Specifications, of Provisional Operating License DPR-22.
On September 17, 1973, sodium pentaborate solution was found in the No. 12 Stand-by Liquid Control pump lubricating oil. An investigation of the problem revealed that the stuffing box drain valve was closed, which caused the normal pump packing leakage to collect in the stuffing box until it leaked into the crankcase through the plunger stub ports.
The drain valve was immediately opened.
It was deter-mined that the stuffing box drain valve had been closed on or about September 17th for painting of the pump mounting base.
The No. 12 pump crankcase was drained, flushed, and refilled with new oil.
The No.11 SBLC pump was inspected and also found to have the stuffing box drain valve closed; however, the amount of solution which accumulated in the stuffing box was not sufficient to result in leakage into the crankcase.
The drain valves will be seal wired in the open position to prevent future inadvertent closure.
This occurrence did not affect safe operation of the plant since the redundant Standby Liquid Control pump was fully operable.
Standby Liquid Control pump operability has not been compromised on any previous occasions due to inadvertent closure of the stuffing box drain valves.
Very truly yours, L 0 Mayer, PE Director of Nuclear Support Services 9211230307 730925 m o rMr cc:
J G Keppler PDR ADOCK 05000263 (M
G Charnoff S
PDR Minnesota Pollution Control Agency--Attn. K Dzugan
- _