License 21-15766-02 for Detroit Bio-Medical Labs Inc, Authorizing Use of 20 Mci I-125 in in Vitro Medical Diagnostic Testing
ML20127K769
Person / Time
Issue date: 05/03/1985
From: Matson E
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To:
Shared Package
ML20127K775 List:
References
21-15766-02, 21-15766-2, NUDOCS 8505220184
Download: ML20127K769 (2)


Text

_

r=p = =.=

4 l N#C Form 374 1

2

[

"E

} is so U.S. NUCLEAR I.EGULATORY CoMMISSloN

" E8 r

1 0

(

l MATERIALS LICENSE

[

l l'ursua~nt to the Atomic Energy Act of 1954, as amended, the Energy Reorganisation Act of 1974 (Public Law 93-438), and Title 10,

[

j Code of Feieral Regulations, Chapter I, Parts 30,31,32,33,34,35,40 and 70, and in reliance on statements and representations r

j heretofore made by the licensee, a heense is hereby issued authorizing the licensee to receive, acquire, possess, and transfer byproduct, f((

1 source, and special nudear material designated below; to use such material for the purpose (s) and at the place (s) designated below;to I

deliver or transfer such material to persons authorized to receive it in accordance with the regulations of the applicable Part(s). This

}

license shall be deemed to contain the conditions specified in Section 183 of the Atomic Energy Act of 1954, as amended, and is i fl conditions spreified below.

subject to all applicable rules, regulations and orders of the Nudear Regulatory Commission now or hereafter in effect and to any r

}

)t Licensee h

1

[

I 1.

Detroit Bio-Medical Laboratories, Inc.

3. License number 21-15766-02 J

I l

ir L

b a < In.(late May 31, 1990 F

2, 23955 Freeway Park Drive D~ & '.b p' p

7 I

4'. i?sp'Ititi

)

Farmington Hills, MI 48024 s.:

k

]

5, Docket or

]

030-28635, 21-15766-01 l

,h

}

__6liyproduct, source, and/or A

7. Chemical and/or physleal L 8. Maximum amount that licensee Reference No.

}

I special nuc! car material N,._

form

'[inder this license may possess at any one time i

l U,i

's

}

A. Iodina-125 k[

]E Propackaged kits N [

( A. 20 mil 11 curies

)

A

.Ax

,e f

't 3

P

9. Authorized Uno f

j!

A.

To be used for irj vitro medical ~diastiostic tnsting.

! s/,

<f k

y g ;p 7 (-

.n i

j t

t,4

' ' CONDITIQ[,.

._4 t

e*

d 10.

Licenrodmaterialaallb'ausedonk 11 ensee's facilillos located at I

23955 Fronway Park Driva Farmington H111ms Michigan.

M i

fl

'\\

ti i N/p f) y'

p c

y,with the prov,intons of 'fitte 10, Chapter 1, Coda of Federal Thelicennooshallcom[ Notices,InstructionsandHoportstoWorkers; Inspecti 11.

)

Regulations, Part 19 S

)

f

)

Part 20 " Standards for Prot'octio.n Against Radiation."?

k n

}

w Licensed material shall bn used by.s.4sor imder3thn nupervision of, Raymond P. Zakaria.

J 4

k.

  • j4 h

}

12.

}

)

The liconneo shall not uno licenmod material in or on human beings or in field 13.

j applications khore activity in released except as provided otherwise by specific

)

condition of thin license.

]

[;

14. The licensco in authorized to hold radioactiva motorint with a physical half-life of Insa than 65 days for decay in-storaga bnfore disposal in ordinary trash providedt l

A.

Radioactive wasto to bn disposed of in thin mannar shall bo hold for decay a minimum of ton (10) half lives.

[

B.

Prior to disposal as normal wanto, radioactiva wanto shall be monitored to

[

l dntarmine that its radioactivity cannot bo distinguinhed from background with i

typical low Inval laboratory survey instruments.

All radiation labels will ba removed or obliterated.

f i

h copy p 6.. 21" % g 850503

......q L 3 f) kp. py,,, n.1 %

lU Me~03 PDM

/...._.....a L

p u m m_u,mu mmm m mm m mm u s&u m ejus_sms m m m m mm m m m m m m mm m m m m m m,,,,,,

NRC Form 374A U.S. NUCLEAR REGULATORY COMMIS810N 2

2 g

g, License number l

21-15766-02 l

MATERIALS LICENSE l

o SUPPLEMENTARY SHEET 03 -18543 l

ll 1

I

15. The G-?! survey meter shall be calibrated at least annually and following repair l

by the manufacturer or by other persons specifically authorized by the Commission I

or an Agreement State to perform such services.

I I

When survey results of areas where rad'oactive material is ued or stored exceed f

i 16.

200 dpm/100cm the licensee shall decontaminate to levels below 200 dpm/100cm'.

l 8

ll

17. The licensee shall follow the procedures in Appendix G of Regulatory Guide 10.8 lll (1980) for general rules for safe use of radioactive material in the laboratory, 18.

Except as specifically provided othoryiseyby-this license, the licensee shall possess l

and use licensed material descri%in Itersi 6f {p,gnd 8 of this license in accordance with statements.* representations, and rocedures contained in application l

dated April 10, 1985. 'Q(jddslear Regulatory Commii'sfonly regulations shall I

govern the licensee's statements in applications or letters, unless the statements aremorerestrictivej%hin' the regulations,

()

l

-n &

G N'~

/

f ll e x Q))

YC ff[.lE l

'l 0

l l

k

Y

(:.19,

/><

L

.i q

.> w%

c s

(

q ;'

o l

( Lfm k3 L

s g

1 g y, w, / <

[

((k))

r,

- 9;

'l

W

(-~

ll p

"pq y,;

g g

.s,--

ji

, m, p

.o o

colp lA j V

j' 4

1

' W %,i c g ;)

Q.

cA 3

s t

aPr j, MD /Q,

(

g p'i n u s y e. ~M..

0)A

{

b ( J i N ' h.',&'

1 V

l

.k.h h

L s

i<

L

+(!.$ x J, - f r g

t h4

[

'T

/%

t

[

l l

I I

I I

i L

t l

l l

l l

l 1

i For the U.S. Nucinar Regulatory Comminnion g

l 1

L I

(

}

Original Signed l

IlY ILV"l.n H. Platnon l D:te itay 3. 1985 Y

i tiatorials 1,1 censing Section, Region !!!

~

~~

l il Col'Y lt t

i l

ji L kasutusuousususavusususumustwsususurJuusLwsusamaLwa*;suwsustsLwsususumussw M