Notice of Violation from Insp on 850301-31
ML20127K285
Person / Time
Site: Summer 
Issue date: 04/30/1985
From:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To:
Shared Package
ML20127K283 List:
References
50-395-85-13, NUDOCS 8505220086
Download: ML20127K285 (4)


Text

C

~

3

\\-

ENCLOSURE NOTICE OF VIOLATION South Carolina Electric & Gas Docket No.-50-395 V. C. Summer-License No. NPF-12

'. The following violations were identified during an inspection conducted on March 1

March 31,1985.

The Severity Levels were assigned in accordance with the NRC Enforcement Policy (10 CFR Part 2, Appendix C).

'I.

Technical Specification 6.8.1 requires that written p'rocedures be established, implemented and maintained covering the applicable procedures recommended in Appendix A of Regulatory Guide 1.33, Revision 2, February 1978. Regulatory Guide 1.33 recommends that general procedures for control of~ maintenance, repair, replacement and modification work be prepared.

General Maintenance Procedure (GMP) 101.008, Seismic and Vital Equipment Area Scaffolding / Shielding Evaluation and Utilization, implements this requirement in the area of pre-installation evaluations of scaffolding.

Contrary to the above requirement, the licensee failed to adequately implement GMP ' 101.008 in that the scaffolding installed in the Diesel Generator Building on March 20 and March 21, 1985, was not adequately evaluated prior to installation for impact on the Diesel Generators during a seismic event.

This is a Severity Level IV violation (Supplement I).

2.

10 CFR 50.54(1) requires that the licensee designate individuals to be responsible for directing the licensed activities of licensed operators and that these individuals be licensed as senior operators pursuant to 10 CFR 55.

Contrary to the above, from February 3 to March 20, 1985, a control room supervisor without a valid senior operator's license was designated to direct and did direct the licensed activities of licensed operators.

This is a Severity Level IV violation (Supplement I).

Pursuant to 10 CFR 2.201, you are required to submit to this office within 30 days of the date of this Notice, a written statement or explanation in reply, including: (1) admission or denial of the alleged violations; (2) the reasons for the ' violations if ' admitted; (3) the corrective steps which have been taken and ~ the results achieved; (4) corrective steps which will be taken to avoid further violations; and (5) the date when full compliance will be achieved.

8505220086 850430 PDR ADOCK 05000395 G

PDR

. ~ -

South Carolina Electric & Gas 2

Docket No. 50-395 V. C. Summer License No. NPF-12

. Security. or safeguards information should be submitted as an enclosure to facilitate withholding it from public ' disclosure as required by 10 CFR 2.790(d) or 10 CFR 73.21.

APR 3 01985 Date:

l

m.:

4-

[e P

ENCLOSURE NOTICE OF VIOLATION l South Carolina' Electric & Gas Docket No. 50-395

.V. C Summer.

License:No. NPF-12 The i fo11owing ' violations. were identified during an inspection conducted on i March l March 31,- 1985. The Severity Levels were assigned in accordance-with

^

- :the NRC Enforcement ~ Policy (10 CFR Part42, Appendix C).

1'.
Technical
Specification ' - 6.8.1 requires that written p'rocedures be

. established, implemented and maintained covering the applicable procedures

' recommended in: Appendix A of Regulatory -Guide '1.33, Revision 2, February

-.1978.

Regulatory Guide 1.33 recommends that general procedures for control

?of (maintenance,. repair,. replacement and modification work be prepared.

General 3 Maintenance Procedure - (GMP)- 101.008, Seismic.and -Vital Equipment Area Scaffolding / Shielding Evaluation' and Utilization, implements this requirement in the' area of pre-installation evaluations of scaffolding.

Contrary to the-above requirement, the licensee failed to. adequately

. implement GMP L101.008 in that the scaffolding installed in the Diesel Generator Building on. March 20 and March 21, 1985, was not riequately

' evaluated prior to installation for impact on the Diesel Generators during.

a. seismic event.

This is La Severity Level IV violation (Supplement I).

2.

10JCFR.50.54(1) requires that-the licensee designate individuals to be responsible for directing' the. licensed activities of licensed operators and that these individuals be licensed as senior operators pursuant to 10 CFR 55.

Contrary.to the above, from February 3 to March 20, 1985, a control room

~

supervisor without a ~ valid senior operator's. license was designated-to

, direct and did direct the licensed activities of' licensed operators.

This is a Severity Level IV violation (Supplement I).

Pursuant ~ to 10 CFR 2.201, you are required to submit to this office within 30 days 'of the date of this Notice, a written statement or explanation in reply, including: '(1)' admission' or denial of the alleged violations; (2) the reasons for-'the violationsEif admitted; (3) the corrective steps which have been taken.-

and ' the'.results achieved; (4) corrective steps which will be taken to avoid further violations; and (5) the date when full compliance will be achieved.

o i,

1 L

i.

South Carolina Electric & Gas 2

Docket No. 50-395 V. C. Summer.

License No. NPF-12 '

. Security or ' safeguards information should be submitted as an enclosure to facilitate withholding 'it from public disclosure as required by 10 CFR 2.790(d)-

or 10 CFR 73.21.