p*G,4'o, UNITED STATES 8
},
NUCl. EAR REGULATORY COMMISSION
's REGION I ATTACHMENT D 831 PARK AVENLM 4, * *..,o',g 4
KING OF PRUS8:A, PENNSYLVANIA 19408 JAN I 1 1985 Docket No. 30-4951 License No. 22-00057-06 MEMORAhDUM FOR: Darrell G. Wiedeman, Chief, Nuclear Materials Safety Section 1, Region IV FROM:
John D. Kinneman, Chief, Nuclear Materials Section A, Region I SUSJECT:
REPORTOFLEAKINGMINNES0TAMININGANDMANUFAC1URING(3M)
SEALED SOURCES In May 1984, this office was notified by one of our licensees, the Fedaral Emerger.cy Management Agency, that several of their 3M sealed sources had been reported to them as leaking. The licensee submitted a written report of this incident to this office by letter dated June 25, 1984 (copy attacned). An inspection of this licensee was performed on December 19, 1984. The inspector obtained a copy of a draft licensee report which provides additional information abcut the leaking sources. We are attaching a copy of the draft licensee report.
Since 3W is located in Region III, we are sending you copies of these reports for your possible use during a future inspection of that licensee.
Please call me (FTS 488-1252) if you need any additional information.
Jo n D. Kinneman, Chief Nu lear Materials Section A Attachments:
As Stated 8505210479 850517 FB 8 RE93 LIC30 22-00057 -C6 PDR
my gogvo -F/4f t' g'
' - '%" ( Federal Emergency Management %8c"y
- k, [
Washington, D.C. 20472 U.S. Iluclear Regulatory Commission, Region I
' 1984 ATTENTION-Mr. Jack Davis Office of inspection and Enforcements 631 Park Avenue King of Prussia, Pennsylvania 19406
Dear Mr. Davis:
On May 17, 1984, I called and notified you of a leaking sealed source in a CDV-782 soarce set issued to Rhode Island.
I agreed to furnish you a report when the investigation was completed.
On Jane 13 I called to notify you of the leaking sources in Texas and Massachusetts and the actions that FEMA had taken to date.
Since this is no longer an isolateo incident, you requested an interim report.
The enclosed interim report sumarizes the incident to date and what actions have been taken.
Mr. John Hickey, Office of Nuclear Material Safety and Safeguards, called on June 22 concerning the incident.
I agreed to furnish him a copy of the interim report.
I will continue to kecp you advised.
If you wish additional information, I can be reached at (202) 287-3038.
Enclosure Sincerely, lx C
Y Geor0e C. Meyer Chairman, Radiation Control Committee Attn:
SL-EMSD-PD cc:
Mr. John Hickey
(@
eu'
\\
flL
-