AEC DISTRICUT'C': FOR PART 50 COCMET f.1ATEGl AL (TET.iPOR ARY FOR. )
CONTROL NOL /8Sf FILE:_ MONTHLY REPORT FILE F RO.'.1: Northern States Power Co DATE OF COC DATE REC'D LTR TWX RPT OTHER Minneapolis, Mn 55401 2-6-75 2-12-75 xxu G H veils TO:
KRC one signed SENT LOCAL PDR U
CLASS UNCLASS PROPINFO INPUT NO CYS REC'O DOCKET NO:
un 50-263 1
DESCRi? TION:
ENCLOSURES:
Ltr trans the following:
Monthly Report for nrmary 197s
.d4 g {,
Plant & Component Operability & Availability
,d d 1*,', ( i d.
This Report to be used in preparing Grey cy
,C.(,; p,
Book by Plans & Opdrations.
Nc. of Cys Rec'd 1
SLANT NAME:
Mon t. ice llo i
FOR ACTlON/li:FOR'. AT;ON 2-12-75 ehf 1 3UTLER (S)
.SCHWENCER (S)
ZIEMANN (S)
REGAN (E) 1/ Copies W/ Copics
/ W// Copies W/ Copies
- LARA (s)
STOLZ (S)
DICKER (E) 12AR (S) f/ Copies Wf Copies W/ Copies
/ Copies
'ARR (S)
VASSALLO (S)
KNIGHTON (E)
. THOMPSON 1/ Copies W/ Copies W/ Copies W/ 2 Copies
/
3IEL (S)
PURPLE (S)
YOUNGBIDOD (E)
?/ Copies W/ Copies W/ Gopics W/ Copies lG FILE 3 INTERN AL DISTTH SUTION TECH REVIEW DENTON LIC ASST A/T IND
.:.U FDR -
SCHROEDER GRIMES fDIGGS (S)
BRAITMAN
- GC, ROOM P-506-A MACCARRY GAMMILL GE ARIN (S)
SALTZMAN
.UMTZING/ STAFF KNIGHT KASTNER GOULBOURNE (S)
B. HlfdT ASE PAWLICKI BALLARD KREUTZER (E)
I#1BUSSO SHAD SPANGLER LEE (S)
PLANS OYD STELLO MAIGRET (S) fMCDONALD
.00REl(S) (BWR)
HOUSTON ENVIR0 REED (E) dHAPMAN l
EYOUNG (S) (PWR)
NOVAK MULLER _
SERVICE (S)
DUBE w/ input KOVHOLT (S)
ROSS DICKER SHEPPARD (S)
E. COUPE OLLCR- (S)
IPPOLITO KNIGKf0N SLATER (E)
. COLLINS TEDESCO YOUNGBLOOD SMITH (S)
D. THOMPSON (2)
ENISE IDNG REGAN TEETS (S)
KLECKER EG OFR LAINAS PROJECT LDR WILLIAMS (E)
EISENHUT g
ILE & REGION (2)
PENAROYA
.R. WILSON WILSON (S)
~
STEETE VOLIMER HARLESS INGRAM (S)
/l;! M. _
EXTERNAL DISTR lEUTION _
ra) d l-LOCAL PDR #h,v n e. < > o N J, /Mr5 (1)(2)(10)-NATIONAL LASS _
l-PDR S AN/LA/NY
,l-TIC ( ABERNATHY) l-NSIC(BUCHANAN) l-W. PENNINGTON, RM-E-20lG.T.
l-BROOKHAVEN NAT LA3 1-CONSULTANIS l-ASLB l-G.ULRIKSON,0RNL l-NEWTON ANDERSON NEWMARK/BLUME/ACBASIAN 1-AGMED RUTH GUSSMA.'i 13g 1.6-ACRS EOLDING 11hh ROOM B-127 G.T.
o 3
1-J. RUNKLE S RM ? ^
'2025 d bbnticello Nuclear UNIT Generatinn Plant IMTI!, FEBRUARY 5,1975 COMPLETED BY W. A. SfMMLA DAILY UNI T P0hlin (tm0T 50NTli JANUARY 1975
-net
-net DAY AVERACE fl0URLY Mi{e Y
ARPAGF HOMY Mie 1
418 25 2
2 408 26 2
3 411 27 4
4 378 28 2
5 344 29
-2 6
343 30 4
7 345 31 3
8 34 3 9
313 10
-6
-4 11
-4 12
-4 13
-4 14
-3 15 16
-3
-3 17
-3 IS-
-3 19
-3 20
-3 21
-3 22
-1 23
-5 24 i
i l
t e-
,--sm.e e
w
.e,
,aw.-
,-ww,w
,,.2026)
' " "
- R6', 1 UNIT MhlE FDNTICELL UCLEAR GEN 1 RATING PIANT-IATE FEBRUARY 5, 1975 COMPLETED BY W. A. SilAMLA (612) 29Fil51 Ext. 111 OPERATING STATUS 1.
REPORTING PIRIOD:
0000750101 TO 2400750131 GROSS 10URS IN REPORTING PERIOD:
744 2.
CURRFATLY Atrl10RI2ED P0hlR LE\\Til Wt 1670 We-hrf 53S 3.
POWER LEVEL TO h11101 RESTRICTED (IF ANY):
None 4
RFASONS FOR RESTRICTIONS (IF AhT):
Tills CUSUIATIVE
- ON111 YR-T0 DATE
'IO DATE 1
5.
Il0URS RFACTOR WAS CRITICAL 219.2 219.2 23.625.8i 6.
REACTOR RESERVE Si!UITOWN 110URS 0
0 937.0:
7.
Il0URS CINERATOR ON-LThTi 2E5 215.5 22.627.6; 8.
UNIT RESERVE SillJITCLN llOURS 0
0 0
9.
GROSS tiler 31\\L TOLTR CENERATED GNI) 245.697,6 245.697.6 41.680.675.4!
- 10. GROSS ELECTRICAL P0hliR GIEERATED (Mh11) 83,310_ _
83.310 11.534.070
- 11. NI.T ELECTRICAL IUdER G1:hTRATED O!MI) 77.54.0
_77.540 11.019.17.4
- 12. RFACTOR AVAllABILITY FACTOR (1)
- 29. 5 % ____
29.5%
75.1
- 13. UNIT AVAILABILI1T FACTOR (2) 29.0%
29.0%
71.9
- 14. UNIT CAPACITY FACTCR (3) 19.4%
19.4%
65.1
- 15. FORCED OUTAGE RATE (4) 0.0%
0.0%
13.91
- 16. ShUfD0KNS SGIEDULEP TO BEGIN IN NEXT 6 FOSTIS (STATE 'iYPE, DATE, AhIl DURATION OF EAGI):
17.
IF SFUfDOWN AT END OF REPORT PERIOD, ESTD!ATLD DATE OF STARTUP:
2/7/75 (1) REACTOR AVAIIABILITY FACTOR = IDJRS RFACTOR WAS CRITICAL
- 100 GITTGE5 IN REliflE PLRIOD (3) UNIT CAPACITY FACTCR = NL~i ELECTRICAL F0WER GENERATED
- 100 NET DDDNSTRATWGROSS liMITlTTHVRTING PL1tTOU (4) FORCED OUTAGE RATE = FORCED OtfrAGE liOURS
- 100 IIG23TENERATOR ON-LINb + IURCED OUTAGE HOUR $
l 1
1
._._m ouulteLw auttuul WIT N G M TI.NG N :].
SIM1ARY Operated as base loaded tmit. Outage DATE February 6, 1975 ' '- l described below REl' ORT MO:.11 JANUARY COMPLEITI) IlY W. A. Shamla s
UNIT SILTITOXNS TYPE MIiG10D OF F-FORCI:D IURATION SIKTITING IG.7 NO.
DATE S-SCIIEIULED (IKURS)
REASON (1) lliE REACTOR (.2)
C0iiCTS 1
750110
'S 528.5 C
A Also replaced portions of 4" recirc valve bypass lines that were found cracked.
Completed inspection requirements of i
IE Bulletin #75-1.
l i
I (1) 11EASON:
(2) 3 H iiC W A-EQUIIMDJ FAILURE (EXPIAIN)
A-31\\ Nil.
B-is!\\IN. OR TEST B-31CU *d.
C-REIVELING SCRAM D-REGUL\\ TORY RESTRICTION C-/M Ctr.T E-OPER\\ TOR TRAINI."G G SCR41 i
LICENSE EXXIINATION F-ADMINISTR\\TIVE G-OPERATIONAL. ERROR
.(Explain) f H-01]IER (Explain)
.