B14345, Forwards Addl Info Re GL 92-01,rev 1, Reactor Vessel Structural Integrity,10CFR50.54(f), in Connection W/Telephone Discussion Held on 930113 W/Nrc Related to Upper Shelf Energy of Plant Reactor Vessel

From kanterella
(Redirected from ML20127J227)
Jump to navigation Jump to search
Forwards Addl Info Re GL 92-01,rev 1, Reactor Vessel Structural Integrity,10CFR50.54(f), in Connection W/Telephone Discussion Held on 930113 W/Nrc Related to Upper Shelf Energy of Plant Reactor Vessel
ML20127J227
Person / Time
Site: Haddam Neck File:Connecticut Yankee Atomic Power Co icon.png
Issue date: 01/15/1993
From: Opeka J
NORTHEAST NUCLEAR ENERGY CO., NORTHEAST UTILITIES
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML20127J229 List:
References
B14345, GL-92-01, GL-92-1, NUDOCS 9301250074
Download: ML20127J227 (3)


Text

- -

I l

NORTHEAST UTELITIES o.n.re cia... seio.n sir..i. e.,i.n Conn.cs.cui l

.m..-.w our d E' P.O BOX 270

.u,x.*"**"*""""

H ARTFORD, CONNECTICUT 00141-o?70 i

,,M 6,.

[,'C ((

(?03)8% S-5000 January 15, 1993 Docket N.L__iG-211 f!1116 Re: Generic Letter 92-01, Revision 1 i

U.S. Nuclear kegulatory Commission Attention: Document Control Desk Washington, DC 20555 Gentlemen:

Haddam Neck Plant Additional Information Related to the Reactor Vessel Structural Integrity, 10CFR50.54(f)

_(. Generic letter 93-01. Reyliion 11 In a letter dated March 6,1992,f" the NRC Staff issued Generic Letter 92-01, Revision 1, " Reactor Ve::sel Structural Integrity,10CFR50.54{f)."

A response to Generic Letter 92 01 was providad on July 6, 1992,

and additional information was provided to the Staff in a letter dated December 21, 1992.

Consistent with telephone discussions held with the NRC Staff on January 13, 1

1993, Connecticut Yankee Atomic Power Company (CYAPC0) is hereby providing additional information related to the upper shelf energy of the Haddam Neck Plant reactor vessel.

This informtion demonstrates that based on Charpy l

impact testing, the upper shelf energy for the Haddam Neck Plant reactor vessel remains ab1ve 50 ft-lbs through the end of licensed plant life.

(1)

J. G. Partlow latter to All Holders of Operating Licenses or Construction Permits. for Nuclear Power Plants (Except Yankce Atomic Electric Company, Licensee for the Yankee Nuclear Power Station),

" Reactor Vessel i

structural Integrity, 10CFR50.54(f), (Generic Letter 92-01, Revision 1),"

dated March 6, 1992.

(2)' J. F. Opeka letter to the U.S. Nuclear Regulatory Commission, " Reactor Vessel Structural Integrity, -10CFR50.54(f),

(Generic letter 92-0],-

Revision 1)," dated July _6, 1992.

(3)

J. F. Opeka letter to _the U.S. Nuclear Regulatory Commission, " Additional Information Related to the Rea: tor Vessel Structural-Integrity l

10CF50.54(f), (Generic letter 92-01, Revision 1)," dated December 21, 1992.

I 9301250074 930115 PDR ADOCR-0"400213 2100,fu

. ff i

n P

PDR osaw stv 4-es -

N

,n,,,

.. -. ~. -l

i s

i U.S. Nuclear Regulatory Commission B14345/Page 2 January 15, 1993 1

i In accordance with 10CFR50.54(f), CYAPCO, on behalf of the Haddam Neck Plant, hereby proviries the attached additional information to supplement the j

" Required Information" section in the generic letter.

l If you have any questions, please contact us.

Very truly yours, CONNECTICUT YANKEE ATOMIC POWER COMPANY 1

b' i

3. F. Opeka)

+

Executive Vice Pres.i nt

}

Enclosure i

l cc:

T. T. Martin, Region 1 Administrator i

A. B. Wang, NRC Project Manager, Haddam Neck Plant W. J. Raymond, Senior Resident inspector, Haddam Neck Plant i

Subscribed ano sworn to before me this,/_[_dayof

.s 4

, 1923 j

l

'Mh4pcL' b -

[]hgbe':_

j Notary PM1ic Date Commission Expires: d L 3/ 9 3 i

i e

1 e

~

,.,.. +

.2

,g-,.w....w-,

..,4 k

j 1

Docket No. 50-213 BL11%

f i

s i

J 1

4 i

l HADDAM NECK PLANT i

i Additional Information for the 4

Respanse to Generic Letter 92-01 2

i t

i i

i i

i 1

January 1993 t

~.

-,