ML20127G816

From kanterella
Jump to navigation Jump to search
Forwards Exam Rept 50-395/92-301 Administered During Wk of 921207.Simulator Fidelity Rept Also Encl
ML20127G816
Person / Time
Site: Summer South Carolina Electric & Gas Company icon.png
Issue date: 01/06/1993
From: Peebles T
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To: Skolds J
SOUTH CAROLINA ELECTRIC & GAS CO.
Shared Package
ML20127G820 List:
References
NUDOCS 9301220082
Download: ML20127G816 (3)


See also: IR 05000395/1992301

Text

{{#Wiki_filter:p - . . ~ _

                                         January 6, 1993
    South Carolina Electric and Gas Company
   ATTN: Mr. J. L. Skolds, Vice President
                Nuclear Operations
    V. C. Summer Nuclear Station
    P. O. Box 88
   Jenkinsville, SC        29065
    Gentlemen:
    SUBJECT:     V. C. SUMMER NUCLEAR STATION EXAMINATION REPORT N0. 50-395/92-301
   This refers to the Nuclear Regulatory Commission (NRC) initial examinations
    led by Edwin Lea during the week of December 7, 1992. These examinations were
    administered to employees of your company who had applied- for licenses to
   operate your V. C. Summer Nuclear Station. At the conclusion of the examina-
    tion, preliminary findings were discussed with those members of-your staff
    identified in the Examination Report, Enclosure 1.
   A Simulator Fidelity Repnrt is included as Enclosure 2.        A copy of the written
    examination questions and answer keys, as noted in Enclosure.3, was provided                   ,
    to members of the facility's training staff at the conclusion of the examina-
    tions. The facility's training staff had no post-examination comments.
                                                                                                   1
   The Generic Fundamental Examination Section (GFES) was not administered to
   employees at the V. C. Summer Nuclear Station during the previous two' exam
   periods.
    In accordance with 10 CFR 2.790 of the Commission's regulations, a copy of
                                                           -
    this letter and the enclosures will be placed in the NRC Public Document Room.
   Should you have any questions concerning this examination, please contact us.
                                                   Sincerely,
                                               (Original signed by T. A. Peebles)

L Thomas A. Peebles, Chief l Operations Branch

Division of Reactor-Safety
   Enclosures:                                                                                     ,
    1. Examination Report 50-395/92-301
                                                                                                   J
   2.     Simulator Fidelity Report
   3.     Written Exam Questions and Answer
            Keys (Document Control Desk Only)
                                                                                                t
   cc w/encls 1 and 2:
    (See page 2)

! 210001 L l l L

   _9301220082
      Drl
                     930106
            ADOCK 0500        5
                                                                                      [[hh'       j
                       _.               _         _       _    .
    South Carolina Electric and Gas Company- 2 January 6, 1993
    cc w/encls 1 and 2:
    K. W.-Woodward, Manager
    Nuclear Operations Education
      and Training
    South Carolina Electric & Gas Company
    V. C. Summer Nuclear Station
    P. O. Box 88, Mail Code P-40
   Jenkinsville, SC 29065
    R. J. White
   Nuclear Coordinator
    S.C. Public Service Authority
    Virgil C. Summer Nuclear Station
    P. O. Box 88 (Mail Code 802)
   Jenkinsville, SC 29065
    G. J. Taylor, General Manager
    Nuclear Plant Operations
    South Carolina Electric & Gas Co.
    Virgil C. Summer Nuclear Station
    P. O. Box 88 (Mail Code 300)
   Jenkinsville, SC 29065
   J. B. Knotts, Jr., Esq.
   Winston and Strawn
    1400 L_ Street, NW
   Washington, D. C. 20005-3502
   Chairman
    Fairfield County Council
    P. O. Drawer 260
   Winnsboro, SC 29180
   Heyward G. Shealy, Chief
   Buread of Radiological Health
   S.-C. Department of Health
      and Environmental Control
   2600 Bull Street
   Columbia, SC 29201
  .Mr. R. M. Fowlkes, Manager
  - Nuclear Licensing-and Operating Experience
   South Carolina Electric & Gas Company
   Virgil C. Summer Nuclear Station-
   P. O. Box 88-
   Jenkinsville. SC 29065
   bcc w/encls 1 and 2:'
    (See page 3)
                                                                 ,

~~

                     ..    ..   .            .                         .- -
          South Carolina Electric and Gas Company 3                January 6, 1993
          bec w/encls 1 and 2:
          G. Wunder, NRR
          A. Gibson, DRS
          D. Verrelli, DRP
          F. Cantrell, DRP
          L. Lawyer, DRS
          E. Lea, DRS
          M. Morgan, PNL
          Operator Licensing Branch, DRCH, NRR
          NRC Resident Inspector
          U.S. Nuclear Regulatory Commission
          Route 1, Box 64
          Jenkinsville, SC 29065
          bec w/encls 1, 2, and 3:
          Document Control Desk
          bec w/o encls:
           IMS, RII
                                                                                   ,
          RII:DRS                   RII:DRS       RII:DRP    RII:DRS/              _
          Ele    1/btm              L    yer      F     rell         s
          1/ 5 /93                  1/t'/93       1/6/93     1/f--/93
         . Doc: 130lrpt el
                        .