ML20127G714

From kanterella
Jump to navigation Jump to search
Forwards Safety Relief Valve Failures & Challenges for 1984, in Accordance w/NUREG-0737,Item II.K.3.3
ML20127G714
Person / Time
Site: FitzPatrick 
Issue date: 05/17/1985
From: Brons J
POWER AUTHORITY OF THE STATE OF NEW YORK (NEW YORK
To: Vassallo D
Office of Nuclear Reactor Regulation
References
RTR-NUREG-0737, RTR-NUREG-737, TASK-2.K.3.03, TASK-TM JPN-85-43, NUDOCS 8505210124
Download: ML20127G714 (3)


Text

4 123 Main Street y-White Plains, NewYork 10601 914 681.6200

  1. > NewYorkPbwer 4# Authority Iby 17,1985 CGtF85-43 Director of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Washington, D.C.

20555 Attention:

Mr. Domenic B. Vassallo, Chief Operating Reactors Branch No. 2 Division.of Licensing

Subject:

James A. FitzPatrick Nuclear Power Plant Docket No. 50-333 NUREG-0737 Item II.K.3.3 Safety and Relief Valve Failures and Challences

Reference:

1.

NYPA letter, C. A. McNeill to D. B. Vassallo, dated December 6, 1984 (JPN-84-80)

Dear Sir:

NUREG-0737 Item II.K.3.3 requires that challenges to safety and relief valves (SRVs) be reported on an annual basis. to this letter provides a report of challanges and failures as defined in Reference 1, occurring between January 1, 1984 and December 31, 1984.

If you have any questions, please contact Mr. J. A. Gray, Jr. of my l

staff.

l Very truly yours, l

W n

John

. Brons l ienior Vice President l.

Huclear Generation Enc.

l cc: Office of the Resident Inspector l

U.S.-Nuclear Regulatory Commission I

P.O. Box 136 Lycoming New York 13093 og

$7 >

+

ATTACHMENT I TO JPN-85-43 SAFETY RELIEF VALVE-FAILURES AND CHALLENGES

.FOR 19 84 -

, y.,

New York Power. Authority

' James-A. FitzPatrick Nuclear Power Plant Docket No. 50-333 a

~

4 1

?

.s

SAFETY RELIEF YALVE FAILURES AND t ATf " ES 1984 Date Valve Challenges.

Failure Remarks 10/84 02-RV-71C None See Remarks

- Valve serial no. 1052

- The top works ofcthe safety relief valve was removed during a mainte-nance outage because of-suspected pilot valve leakage.

It was sent to Wyle Laboratory for testing which showed pilot valve leakage and setpoint drift. This will be reported as a failure in the 1985 report which will contain details of the test results.

10/84 02-RV-71E None See Remarks

- Valve serial no. 1050

- The top works of the safety relief valve was removed during a mainte-nance outage because of suspected pilot valve leakage.

It was sent to Wyle Laboratory for testing which showed pilot valve leakage and setpoint drift. This will be reported as a failure in the 1985 report which will contain details of the test results.

--