CERTIFICATE OF COMPLIANCE 10 CFR H FOR RADIOACTIVE MATEHIALS PACKAGES lE i
1.a CERTIFICATE NUMBER D REVISION NUMBER c PACKAGE BOENTIFiCATiON NUMBER d PAGE NUMBER e TOTAL NUMBER PAGES I 9089 8
USA /9089/A 1
3
!E
,R j
PREAu8tE a This Certificate is issued to Certify that the packaging and Contents described In item $ below. meets the applicable safety standards set forth in Title 10. Code of Federal Regulations. Part 71," Packaging of Radioactive Materials for Transport and Transportation of Radioactive Material Under Certain Conditions.'
k b This certificate does not reiseve the consegnor from compliance with any requirement of the regulations of the U.S. Department of Transportation or other applicaDie regulatory agencies. including tne government of any country through or into which the package will be transported.
l$
- E k
l 3 THIS CERTIFICATE IS 6SSUEO ON THE BASIS OF A SAFETY ANALYSJS REPORT OF THE PACKAGE DESIGN CR APPLICATION I -
l a PREPARED BY(Name and AddressA b TITLE AND IDENTIFIC4 TION OF REPORT OR APPLICATION fj lW;stinghouse Hittman Nuclear Westinghouse Hittman Nuclear Inc.
l Corporation Inc.
Application dated March 13, 1984,
- l!
J i9151 Rumsey Road as supplemented.
E i Columbia, MD 21045 r
j i
- c. DOCxET NuuSEa -
71-9089 4 CONOITIONS I
l This certificate is conditional upon fulfdling the requirements of 10 CFR Part 71, as applicable, and the conditions specified below I
!)E j s.
8 l
(a) Packagi ng fs l
(1) Model No.: HN-100S
!g B
l (2) Description j
l The cask is a steel annulus'84-1/4 inches high by 81-5/8 j
inches in diameter. The cavity is. 75-1/2 inches high by
.g l1 l
75-5/8 inches in diameter. The side walls consist of two g
plys of 1-1/2-inch steel. The 3-inch steel t'ase is i
l integrally welded to the cylinder. The lid is a 3-inch R
8 j
steel plate, stepped to mate with the upper flange of the gl cylinder. A centrally located shield plug is similarly cons tructed. The lid and plug are attached with stud-l bolts and nuts and sealed with Buna N 0-ring gaskets. A j#
g plugged drain line and/or optional vent / test in the j
secondary lid connection is provided.
Four skewed lugs j
welded to the outer shell are used for tie down. There are three cask lifting lugs, three lid lifting lugs, and f
one shield plug lifting lug. The package gross weight is j
approximately 43,000 pounds.
lW I
g
[
(3) Drawings j
E The packaging is fabricated in accordance with Hittman f
Nuclear & Development Corporation Drawing Nos.:
C001 9128, Rev. 4 and C001-5-9129, Rev. 3.
llM
- I l
1
$s G505170292 050506 E
- y PDR L
C i
m a m m mmm mu mm m m m'grw m mm mm wm WMM2K.M.'EVEZUGEm2ELW.MMRusKJELMENNMMET.ERW./A w
'~
..e-
^
L I
m'w-
- CcNDmcNS (continusd) '
e W
q
~
f l Page:2 -~ Certificate No. 9089. - Revision No. 8 - Docket No.' 71-9089 I
!t I
- t 1
it I
il I Sc (b). Contents' j
l
'(1) Type and fonn of material.
l I
n I
Process solids, either-dewatered, solid or solidified, meeting the ltl I
requirements for-low specific activity material.
i
-i l
j lj' (2). Maximum quantity of material per package.
- ll
]
i p-y' Greater than Type A quantity _of radioactive material which may.contain
- lg t
fissile material provided the fissile material does not exceed the
'jF lI limits in 10 CFR 671. 53MThe Weightjf/ the contents, secondary J
I
.. I containers, and shoring must not exceed-17,000 pounds and the internal l
i
-l l decay-heat loadCmust not exceed 2 themal wattsg
{
(a) - For any package. d t
l i 6.
containing water and/or organic substances which could E
I radiolytically gsnerate-combustible gases, determination'must be nade by
~lt I
' tests and measurements-or by analysis of a representative package such lI
/l I
that the folloising crite'ria are met over a p'eriod of time that is twice l
the expectedfshipment time: \\
4f i
e' f
s m 3 m_
E g
(1) The hydrogen generated nust be^ limited to a molar quantity that would t
i be no more than 5% by volumei(or_equivalentflimits for other inflam-K 1
mable gases) of'the'se'condary contaigerl gas voidfif present at STP'
- E.
(i.e., no, moretthag 0 063 g-moles /ftm at:14,.7 psia and;70*F); or l
l 1
g re s, W 4.
a y
g.
(ii) The secondary container and cask cavity must be inerted with a diluent L
to assureethat oxygen must'betiimited to 5% by volume. in those portions
-!y I
I of the package which coulfhave, hydrogsri~ greater than 5%.
"Il I
=
~
I For any package delivered to a carrier for transport,'the secondary container l
- ]l
~
must be prepared for. shipment in the!same manner-in which detemination for g
gas: generation is made.' Shipment period begins when_ the package is prepared
!g gl ~
(sealed) and must be comoleted within twice the expected shipment time.
lK l
ll
-l l; (b)T For any package shipped within 10 days of preparation, or within 10 days
'I after venting of drums or other secondary containers, the determination in l
$j (a) above need not be made, and the time restriction in (a) above does not g
.i g
a pply.
y i
1 i
I 7.
Except for close fitting contents, shoring must be placed between the secondary ll 1
containers and cask cavity to minimize movement during nomal conditions of l
l trans port.
lE g
l lE
- 8.
The lid and shield plug lifting lugs nust not be used for lifting the cask, and g
I
'shal1 be covered in transit.
- E i
'l 19.
. Packagings without a drain line must be provided within the operational vent / test
{
j connection in the cask secondary lid.
jg I'10.
The drain line and optional vent / test connection must be appropriately plugged lt E
i I
and sealed prior to transport.
E i
't i
N I_
_h g'i -
~
J
-- ------___-----__?NMMMPEPWHE9E5h___--------------m-- M.
,,i ll CcNolTl:NS (conunuid) l l' Page 3 - Certificate No. 9089 - Revision No. 8 - Docket No. 71-9089
'E I
- E i
'lRi
'E s
11.
Prior to each shipment, the packaging lid seals, if opened (or if the security l
J seal is broken), nust be inspected. The seals must be replaced with new seals g
if inspection shows any defects or every twelve months, whichever occurs first.
- E
!E ii12. By September 1,1984, the packaging must be leak tested at least once every twelve
?
months in accordance with Leak Test Procedure STD-P-02-002, Re-1. O, dated f
February 2,1984.
Each cask which has been damaged or repaired in the area
!g of a seal must also be tested prior to subsequent use; nomal gasket maintenance l$
does not require a subsequent test.
lE
?(
Ii13. Packagings fabricated after November 30,_1983, must be constructed of A-516,
,3 q H-,m,u.
j Grade 70 carbon steel.
1
,;(,-s s
'p
- 14. The package authorized by; this -certificate must be transported on a motor lE E
vehicle, railroad car, ai,rcraf t, inland watercraf t, or hold or deck of a seagoing i
i vessel assigned for the, sole use of the licensee.
f$
i M
- 15. The package authorize'd' by this certificate is hereby approved for use under the general license prov.isions of 10 CFR Q71.12.
l df 1
s l16. Expiration date:, November 30,11988.
2 ',
REFEREtCES
^
i{g i
< s Westinghouse Hittman Nudlear Incorpofatid application da'ted March 13,'1984.
W s
g Supplement dated: April,19, 1985.
s E
i-E FOR THE U.S. ~ NUCLEAR REGULATORY COMMISSION l
lE Ch les ac ona d, Chief iE i
Transportation Certification Branch lj' i
' Division of Fuel Cycle and
)
' Material Safety, NMSS I
E4Y061985 l
lDate:
s E
I lE l
'l y
n f
5 9
l ik-------.___________-----------
.----m.
,8 M N,g
&t UNIT 3D STATES NUCLEAR REGULATORY COMMISSION e
n h
WASHINGTON, D. C. 20555
\\...../
Transportation Certification Branch Approval Record Model No. HN-100S Package Docket No. 71-9089 By application dated April 19, 1985, Westinghouse Hittman Nuclear Incorporated requested an amendment to the Model -No. HN-100S package. The amendment provides for an alternate method of installing the optional drain plug to the package.
The change has no significant impact on the ability of the package design to meet the requirements of 10 CFR Part 71.
COMBUSTIBLE GAS MIXTURES Conditions were imposed on packages containing water and/or organic substances to limit the accumulation of radiolytically generated gases over the shipping period to preclude the possibility of significantly reducing the packaging effectiveness due to explosion.
Part of the conditions included "...it must be detemined by tests and measurements of a representative package whether or not...."
There is no reason to believe that calculational methods could not be used as means of detemining gas generation. So as not to preclude a valid analysis,.
part of the condition to limit the accumulation of radiolytically generated gases is revised to read "...it must be detemined by tests and measurements or by analysis of a representative package whether or not...."
The analytic approach involves detemining the hydrogen generated in the waste by radiolysis based on the absorbed dose of the waste over a given period of time. To satisfy the condition to preclude a cembustible mixture, the period since closure and twice the shipping time must be considered. The calculation requires that the properties of the waste are known. These properties may be determined from test and measurement of representative waste foms or from data that is applicable to the waste form. The determination should be documented and retained as part of the records for the shipment.
]AS*
Char es. MacDonald, Chief Transportation Certification Branch Division of Fuel Cycle and Haterial Safety, RISS Date:
0 6 BBS