APPENDIX B NOTICE OF DEVIATION Louisiana Power & Light Company Docket:

50-38 ~

Waterford 15 team Electric Station License: MPF-38 EA 85-10 based on the results of NRC inspections the following deviation was identified, j

Failure to Perform Test in Accordance with FSAR Conrnitment LP&L's Final Safety Analysis Report (FSAR) requires that all hydrostatic tests confom to the requirements of ASME III, Class 2 and 3,1974 Edition, Sumer 1976 Addenda. Article NC-6000. " Testing," which requires that " vents shall be provided at all high points of the component or system in the position in which the test is to be conducted to purge air pockets while the component or system is filling."

Contrary to the above, the NRC staff's examination of 27 hydrostatic document test packages, including the applicable valve lineup sheets and isometrics, revealed that for each of the corresponding hydrostatic tests, high point vents had no been used. An examination of the hydrostatic test index revealed that FCR-1CP-19 Revision 2 deleting the use of high point vents, was issued subsequent to all the hydrostatic test having been completed.

j Ref: $$ER-7:A-242 This is a deviatior..

Louisiana Power & Light Company is hereby requested to provide in writing within 30 days of the date of this Notice as description of the corrective steps which have been taken regarding these deviations, corrective steps taken to avoid further deviation from consnitments made to the Commission, and the date when these actions were or will be completed.