ML20127A039

From kanterella
Jump to navigation Jump to search
Responds to NRC 850711 Comments Re Util Conformance to Reg Guides 1.52,1.140 & 1.143 Concerning Mobile Radwaste Solidification & Liquid Radwaste Sys.Process Control Program Will Be Submitted by 850810
ML20127A039
Person / Time
Site: Perry  
Issue date: 07/24/1985
From: Edelman M
CLEVELAND ELECTRIC ILLUMINATING CO.
To: Youngblood B
Office of Nuclear Reactor Regulation
References
RTR-NUREG-0880, RTR-NUREG-0887, RTR-NUREG-880, RTR-NUREG-887, RTR-REGGD-01.052, RTR-REGGD-01.140, RTR-REGGD-01.143, RTR-REGGD-1.052, RTR-REGGD-1.140, RTR-REGGD-1.143 NUDOCS 8508050363
Download: ML20127A039 (2)


Text

_ _ - _ _ _ - _.

t P.O. BOX 5000.

  • n i
l t

~ isl g n

,p.

sv 4

s i

't<

i,,,

I is v

r 2

- CLEVELAND. OHIO 44101 - TELEPHONE (216) 622-9800 - lLLUMINATING BLOG. - 55 PUBLICSoVARE Serving The Best Location in the Nation MURRAY R. EDELMAN VICE PRESIDENT NUC LE AR July 24, 1985 PY-CEI/NRR-0301 L Mr. B. J. Youngblood, Chief Licensing Branch No. 1 Division of Licensing U.S. Nuclear Regulatory Commission Washington, D.C.

20555 Perry Nuclear Power Plant Docket Nos. 50-440; 50-441 Conformance with Regulatory Guide 1.52, 1.140 & l.143

Dear Mr. Youngblood:

Attached is our response to your comments transmitted July 11, 1985 on CEI's conformance to Regulatory Guides 1.52, 1.140 and 1.143, concerning the mobile radwaste solidifi-cation system and the liquid radwaste system for Perry Units 1 and 2.

If you have any further questions concerning this matter please feel free to contact me.

Very truly yours, Wt Murray R. Edelman Vice President Nuclear Group MRE:njc Attachment ec: Jay Silberg, John Stefano (2)

J. Grobe pe988st8:8%r Booi

\\\\\\

id

Attachment PY-CEI/NRR-0301 L Comment 1:

Since CEI does not plan to utilize the UNI system to solidify Perry radwastes, the conclusions documented in Section 11.4 of the Perry SER (NUREG-0887) are no longer valid. There-fore, CEI is requested to submit information on the mobile system which will be used for this purpose, in sufficient detail to satisfy the acceptance criteria of Section 11.4 of the Standard Review Plan (NUREG-0880). The mobile system and CEI's Process Control Program will have to be approved by the NRC prior to solidification of any waste.

Response

CEI will utilize a mobile system for solidification of Perry radwaste. A detailed description of this system and the solidification process is provided in the "NUS Process Services Corporation Topical Report on Radwaste Solidif-ication System", PS-53-0378, Rev. O, which has been found to be acceptable for referencing in license applications by letter from NRC (Cecil 0. Thomas) to NUS (R. H. J. Powell),

dated May 30, 1985.

CEI's Process Control Program will be submitted under separate cover by August 10, 1985.

Comment 2:

CEI indicates that portions of the liquid radwaste system were declassified from Safety Class 3 to a non-safety class.

It is the staff's position that the liquid radwaste com-ponents should be Quality Group D as identified in Regulatory Guide 1.26, and should meet the requirements of Table 1 of Regulatory Guide 1.143.

CEI's response to the staff's position is requested.

Response

CEI's liquid radwaste system components do meet the Quality Group D criteria as identified in Regulatory Guide 1.26 and also the requirements of Table 1 of Regulatory Guide 1.143.