ML20126M354

From kanterella
Jump to navigation Jump to search
Comments on Draft SRP for geologic-seismologic Reviews of Umtrap Documents.Section 1.2.2.3.1.2,Step 1,unclear. Earthquake Should Be Moved to Province Boundary & Attenuated to Determine Peak Horizontal Acceleration
ML20126M354
Person / Time
Issue date: 07/10/1985
From: Hawkins E
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
To: Higginbotham L
NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS)
References
REF-WM-39 NUDOCS 8508010326
Download: ML20126M354 (2)


Text

y p t tr UNITED STATES f

NUCLEAR REGULATORY COMMISSION l

REGloN IV

,e URANIUM RECOVERY FIELD OFFICE

DENVER, L

DO 80225 WM Record file WH*roitct JUL 101985 DocLetNo.

PDR _a__

LPDR -____

URF0:SLW

. Distr.ibution:

URL 6 L A2/ n Enz-. M L ha Ll/endea m I d-rficA/yn/L Leo B. Higginbotham, WMLU MEMORANDUM FOR:

r

- gt7 Division of Waste Management (Re!crn to WM 523 SS)

FROM:

Edward F. Hawkins, Chief Licensing Branch 1 Uranium Recovery Field Office, Region IV

SUBJECT:

URF0 COMMENTS ON THE DRAFT STANDARD REVIEW PLAN (SRP) FOR GE0 LOGIC-SEISM 0 LOGIC REVIEWS OF UMTRAP DOCUMENTS The URF0 staff has reviewed in detail the draft SRP for Geologic-Seismologic Reviews of UMTRAP Documents. As a result of our review, the URF0 staff found the document well written, concise and easily followed. Our only comments on the document content are as follows:

1.

Section 1.2.2.3.1.2, Step (1) - The written discussion under Step (1) is unclear.

Based on the written discussion, it appears that the largest earthquake associated with the tectonic province containing the proposed site should be moved to the site to determine the maximum peak horizontal acceleration for that province. For earthquakes in other tectonic provinces that could influence the site, the earthquake should be moved to the province boundary and attenuated to the site to determine a peak horizontal acceleration.

2.

Section 1.2.2.3.1.2, Step (1), paragraph 2, second sentence - This sentence should read "If the former is greater than the latter..."

so that if the maximum peak-horizontal bedrock-acceleration is greater than the maximum-practical design-acceleration, the viability of stabilizing the pile would be appraised.

sE oo s

no 8509010326 850710 F

GE PDR WASTE e

Wit-39 PDR YP, a

5

=

y

.~ h l 10 ngS 3.

Section 1.2.2.3.2, Surface Faulting - Limiting the distance to a capable fault to 3000 feet may not be adequate. The distance out from a capable fault in which surface disturbance occurs varies dependent on the type of fault (i.e., strike slip, reverse, etc.).

This distance should either be increased to cover all types of faulting or the discussion expanded to recognize the type of capable

~

faulting.

In addition, the document should take potential liquifaction into consideration.

Should there be any questions regarding these comments, please contact Sandra L. Wastler of my staff at FTS 776-2811.

1 W

ard. Ha s, Chief Licensing Branch 1 Uranium Recovery Field Office Region IV

_